Nissan Versa Sedan. Instruction — part 862
TM-354
< DTC/CIRCUIT DIAGNOSIS >
[CVT: RE0F11A]
P0711 TRANSMISSION FLUID TEMPERATURE SENSOR A
Is the temperature calculated by subtracting engine coolant temperature from CVT fluid temperature more
than 37
°C (98.6°F) or is it less than −27°C (−16.6°F)? (With CONSULT)/Is “P0711” detected? (With GST)
YES
>> Go to
NO-1 [With CONSULT: “FLUID TEMP” is 10
°C (50°F) or more]>>INSPECTION END
NO-2 [With CONSULT: “FLUID TEMP” is 9
°C (48.2°F) or less]>>GO TO 3.
NO-3 (With GST)>>GO TO 3.
3.
CHECK DTC DETECTION
With CONSULT
1. Select “SLCT LVR POSI”, “VSP SENSOR”, “ACCELE POSI SEN 1”, “FLUID TEMP” in “Data Monitor” in
“TRANSMISSION”.
2. Record CVT fluid temperature.
3. Start the engine and wait for at least 3 minutes.
4. Drive the vehicle for the total minuets specified in the Driving time column below with the following condi-
tions satisfied.
5. Perform “Self Diagnostic Results” in “TRANSMISSION”.
With GST
1. Cool the engine.
2. Start the engine and wait for at least 3 minutes.
3. Drive the vehicle and maintain the following conditions for 21 minutes or more.
4. Check the DTC.
Is “P0711” detected?
YES
>> Go to
NO
>> INSPECTION END
Diagnosis Procedure
INFOID:0000000009268155
1.
CHECK CVT FLUID TEMPERATURE SENSOR
1. Turn ignition switch OFF.
2. Disconnect CVT unit connector.
3. Check CVT fluid temperature sensor. Refer to
TM-354, "Component Inspection (CVT Fluid Temperature
Is the inspection result normal?
YES
>> Check intermittent incident. Refer to
GI-45, "Intermittent Incident"
.
NO
>> Repair or replace malfunctioning parts.
Component Inspection (CVT Fluid Temperature Sensor)
INFOID:0000000009268156
1.
CHECK CVT FLUID TEMPERATURE SENSOR
Check resistance between CVT unit connector terminals.
SLCT LVR POSI
: D
VSP SENSOR
: 10 km/h (7 MPH) or more
ACCELE POSI SEN 1
: 1.0/8 or more
CVT fluid temperature before engine start
Driving time
−40°C (−40°F) – −31°C (−23.8°F)
17 minutes or more
−30°C (−22°F) – −21°C (−5.8°F)
16 minutes or more
−20°C (−4°F) – −11°C (12.2°F)
13 minutes or more
−10°C (14°F) – −1°C (30.2°F)
9 minutes or more
0
°C (32°F) – 9°C (48.2°F)
6 minutes or more
Selector lever
: D position
Vehicle speed
: 10 km/h (7 MPH) or more
Accelerator pedal opening
: 1.0/8 or more
P0711 TRANSMISSION FLUID TEMPERATURE SENSOR A
TM-355
< DTC/CIRCUIT DIAGNOSIS >
[CVT: RE0F11A]
C
E
F
G
H
I
J
K
L
M
A
B
TM
N
O
P
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> There is a malfunction of CVT fluid temperature sensor. Replace transaxle assembly. Refer to
TM-452, "Removal and Installation"
CVT unit
Condition
Resistance
Terminal
4 – 25
CVT fluid temperature: 20
°C (68°C)
Approx. 6.5 k
Ω
CVT fluid temperature: 50
°C (122°C)
Approx. 2.2 k
Ω
CVT fluid temperature: 80
°C (176°C)
Approx. 0.87 k
Ω
TM-356
< DTC/CIRCUIT DIAGNOSIS >
[CVT: RE0F11A]
P0712 TRANSMISSION FLUID TEMPERATURE SENSOR A
P0712 TRANSMISSION FLUID TEMPERATURE SENSOR A
DTC Logic
INFOID:0000000009268157
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PREPARATION BEFORE WORK
If another "DTC CONFIRMATION PROCEDURE" occurs just before, turn ignition switch OFF and wait for at
least 10 seconds, then perform the next test.
>> GO TO 2.
2.
PERFORM DTC CONFIRMATION PROCEDURE
1. Start the engine and wait for 10 seconds or more.
2. Check the first trip DTC.
Is “P0712” detected?
YES
>> Go to
NO
>> INSPECTION END
Diagnosis Procedure
INFOID:0000000009268158
1.
CHECK CIRCUIT BETWEEN TCM AND CVT UNIT
1. Turn ignition switch OFF.
2. Disconnect TCM connector and CVT unit connector.
3. Check continuity between TCM harness connector terminal and ground.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace malfunctioning part.
2.
CHECK CVT FLUID TEMPERATURE SENSOR
Check CVT fluid temperature sensor. Refer to
TM-356, "Component Inspection (CVT Fluid Temperature Sen-
Is the inspection result normal?
YES
>> Check intermittent incident. Refer to
GI-45, "Intermittent Incident"
.
NO
>> Repair or replace malfunctioning parts.
Component Inspection (CVT Fluid Temperature Sensor)
INFOID:0000000009268159
1.
CHECK CVT FLUID TEMPERATURE SENSOR
Check resistance between CVT unit connector terminals.
DTC
Trouble diagnosis name
DTC detection condition
Possible causes
P0712
Transmission Fluid Tempera-
ture Sensor A Circuit Low
The CVT fluid temperature identified by the
TCM is 180
°C (356°F) or more continuously
for 5 seconds or more under the following di-
agnosis conditions:
• Diagnosis conditions
- Ignition switch: ON
- TCM power supply voltage: More than 11 V
• Harness or connector
(CVT fluid temperature sensor circuit is
shorted to ground)
• CVT fluid temperature sensor
TCM
Ground
Continuity
Connector
Terminal
F44
12
Ground
Not existed
P0712 TRANSMISSION FLUID TEMPERATURE SENSOR A
TM-357
< DTC/CIRCUIT DIAGNOSIS >
[CVT: RE0F11A]
C
E
F
G
H
I
J
K
L
M
A
B
TM
N
O
P
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> There is a malfunction of CVT fluid temperature sensor. Replace transaxle assembly. Refer to
TM-452, "Removal and Installation"
CVT unit
Condition
Resistance
Terminal
4 – 25
CVT fluid temperature: 20
°C (68°C)
Approx. 6.5 k
Ω
CVT fluid temperature: 50
°C (122°C)
Approx. 2.2 k
Ω
CVT fluid temperature: 80
°C (176°C)
Approx. 0.87 k
Ω
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.