Nissan Altima L32. Instruction — part 323
P2004 TUMBLE CONTROL VALVE
EC-413
< COMPONENT DIAGNOSIS >
[QR25DE FOR CALIFORNIA]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
14.
CHECK INTERMITTENT INCIDENT
GI-42, "Intermittent Incident"
.
Is the inspection result normal?
YES
>> Replace intake manifold adapter.
NO
>> Repair or replace harness or connectors.
Component Inspection
INFOID:0000000004349462
1.
CHECK TUMBLE CONTROL VALVE
With CONSULT-III
1. Turn ignition switch OFF.
2. Remove intake manifold adapter. Refer to
EM-26, "Removal and Installation"
3. Visually check the valve for damage and check if foreign matter is caught between the valve and the
housing.
4. Connect tumble control valve actuator harness connector.
5. Turn ignition switch ON.
6. Perform “TUMBLE CONTROL VALVE” in “ACTIVE TEST” mode with CONSULT-III.
7. Touch “ON/OFF” and check that the valve opens and closes.
Without CONSULT-III
1. Turn ignition switch OFF.
2. Remove intake manifold adapter. Refer to
EM-26, "Removal and Installation"
3. Visually check the valve for damage and check if foreign matter is caught between the valve and the
housing.
4. Supply tumble control valve actuator terminals with battery voltage within 2 seconds and check operation.
CAUTION:
Do not apply 12V DC continuously for 30 seconds or more. Doing so may result in damage to the
coil in tumble control valve motor.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace intake manifold adaptor.
Tumble control valve actuator
Operation
Terminal
(+)
(-)
4
5
Open
5
4
Close
EC-414
< COMPONENT DIAGNOSIS >
[QR25DE FOR CALIFORNIA]
P2014 TUMBLE CONTROL VALVE POSITION SENSOR
P2014 TUMBLE CONTROL VALVE POSITION SENSOR
Description
INFOID:0000000004349463
Tumble control valve position sensor is built into the tumble control
valve actuator (2).
The sensor consists of a permanent magnet and Hall IC. It senses
the valve shaft movement and feeds the voltage signals to the ECM.
DTC Logic
INFOID:0000000004349464
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is more than 11V at idle.
>> GO TO 2.
2.
PERFORM DTC CONFIRMATION PROCEDURE
1. Start engine and let it idle for 5 seconds.
2. Check 1st trip DTC.
Is 1st trip DTC detected?
YES
>> Go to
NO
>> INSPECTION END
Diagnosis Procedure
INFOID:0000000004349465
1.
CHECK GROUND CONNECTION
1
: Intake manifold adapter
3
: Tumble control valve
JMBIA0117ZZ
DTC No.
Trouble diagnosis name
DTC detecting condition
Possible cause
P2014
Tumble control valve position
sensor circuit
An excessively low or high voltage from the
sensor is sent to ECM.
• Harness or connectors
(Tumble control valve position sensor
circuit is open or shorted.)
(Accelerator pedal position sensor 2 cir-
cuit is shorted.)
[Crankshaft position sensor (POS) cir-
cuit is shorted.]
(EVAP control system pressure sensor
circuit is shorted.)
(Refrigerant pressure sensor circuit is
shorted.)
• Tumble control valve actuator
(Tumble control valve position sensor)
• Accelerator pedal position sensor
(APP sensor 2)
• Crankshaft position sensor (POS)
• EVAP control system pressure sensor
• Refrigerant pressure sensor
P2014 TUMBLE CONTROL VALVE POSITION SENSOR
EC-415
< COMPONENT DIAGNOSIS >
[QR25DE FOR CALIFORNIA]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
1. Turn ignition switch OFF.
2. Check ground connection E9. Refer to Ground Inspection in
.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace ground connection.
2.
CHECK TUMBLE CONTROL VALVE POSITION SENSOR POWER SUPPLY CIRCUIT-I
1. Reconnect ECM harness connector disconnected.
2. Turn ignition switch ON.
3. Check the voltage between tumble control valve actuator har-
ness connector and ground.
Is the inspection result normal?
YES
>> GO TO 8.
NO
>> GO TO 3.
3.
CHECK TUMBLE CONTROL VALVE POSITION SENSOR POWER SUPPLY CIRCUIT-II
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check the continuity between tumble control valve actuator harness connector and ECM harness connec-
tor.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair open circuit.
4.
CHECK TUMBLE CONTROL VALVE POSITION SENSOR POWER SUPPLY CIRCUIT-III
Check harness for short to power and short to ground, between the following terminals.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Repair short to ground or short to power in harness or connectors.
5.
CHECK COMPONENTS
Check the following.
• Refrigerant pressure sensor (Refer to
.)
• Crankshaft position sensor (POS) (Refer to
EC-281, "Component Inspection"
• EVAP control system pressure sensor (Refer to
EC-318, "Component Inspection"
.)
Is the inspection result normal?
YES
>> GO TO 6.
Tumble control valve actuator
Ground
Voltage
Connector
Terminal
F43
1
Ground
Approx. 5 V
JMBIA1606ZZ
Tumble control valve actuator
ECM
Continuity
Connector
Terminal
Connector Terminal
F43
1
F13
72
Existed
ECM
Sensor
Connector Terminal
Name
Connector Terminal
F13
72
Tumble control valve actuator
F43
1
Refrigerant pressure sensor
E219
1
76
CKP sensor (POS)
F30
1
E10
87
APP sensor
E40
6
91
EVAP control system pressure sensor
B41
3
EC-416
< COMPONENT DIAGNOSIS >
[QR25DE FOR CALIFORNIA]
P2014 TUMBLE CONTROL VALVE POSITION SENSOR
NO
>> Replace malfunctioning components.
6.
CHECK APP SENSOR
EC-429, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 10.
NO
>> GO TO 7.
7.
REPLACE ACCELERATOR PEDAL ASSEMBLY
1. Replace accelerator pedal assembly.
2. Go to
EC-429, "Special Repair Requirement"
.
>> INSPECTION END
8.
CHECK TUMBLE CONTROL VALVE POSITION SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check the continuity between tumble control valve actuator harness connector and ECM harness connec-
tor.
4. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 9.
NO
>> Repair open circuit or short to ground or short to power in harness or connectors.
9.
CHECK TUMBLE CONTROL VALVE POSITION SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND
SHORT
1. Check the continuity between tumble control valve actuator harness connector and ECM harness connec-
tor.
2. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 10.
NO
>> Repair open circuit or short to ground or short to power in harness or connectors.
10.
CHECK INTERMITTENT INCIDENT
GI-42, "Intermittent Incident"
Is the inspection result normal?
YES
>> Replace intake manifold adapter.
NO
>> Repair or replace harness or connectors.
Tumble control valve actuator
ECM
Continuity
Connector
Terminal
Connector Terminal
F43
2
F13
52
Existed
Tumble control valve actuator
ECM
Continuity
Connector
Terminal
Connector Terminal
F43
3
F13
54
Existed