Nissan Altima L32. Instruction — part 334
COOLING FAN
EC-457
< COMPONENT DIAGNOSIS >
[QR25DE FOR CALIFORNIA]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
DETECT MALFUNCTIONING PART
Check the following.
• 10 A fuse (No. 33)
• 40 A fusible link (letter K)
• IPDM E/R harness connector E18
• Harness for open or short between cooling fan relay-2 and battery
• Harness for open or short between cooling fan relay-3 and battery
• Harness for open or short between cooling fan relay-2 and IPDM E/R
• Harness for open or short between cooling fan relay-3 and IPDM E/R
>> Repair open circuit, short to ground or short to power in harness or connectors.
3.
CHECK COOLING FAN RELAY OUTPUT SIGNAL CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R harness connectors.
3. Check the continuity between cooling fan relay-2, -3 harness connectors and IPDM E/R harness connec-
tor.
4. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> GO TO 4.
4.
DETECT MALFUNCTIONING PART
Check the following.
• Harness for open or short between cooling fan relay-2 and IPDM E/R
• Harness for open or short between cooling fan relay-3 and IPDM E/R
>> Repair open circuit, short to ground or short to power in harness or connectors.
5.
CHECK COOLING FAN MOTOR POWER SUPPLY CIRCUIT
1. Disconnect cooling fan motor-1 harness connector.
2. Check the voltage between cooling fan motor-1 harness con-
nector and ground.
Is the inspection result normal?
YES
>> GO TO 7.
NO
>> GO TO 6.
6.
DETECT MALFUNCTIONING PART
Check the following.
• 40 A fusible link (letter M)
• Harness connector E12, E203
Cooling fan relay
IPDM E/R
Continuity
Connector
Terminal
Connector
Terminal
E42
(cooling fan relay-2)
1
E17
42
Existed
E43
(cooling fan relay-3)
1
E18
34
Cooling fan motor-1
Ground
Voltage
Connector
Terminal
E220
1
Ground
Battery voltage
2
PBIB1670E
EC-458
< COMPONENT DIAGNOSIS >
[QR25DE FOR CALIFORNIA]
COOLING FAN
• Harness for open or short between cooling fan motor-1 and battery
>> Repair open circuit, short to ground or short to power in harness or connectors.
7.
CHECK COOLING FAN MOTOR CIRCUIT-I
1. Disconnect cooling fan motor-2 harness connector.
2. Check the continuity between cooling fan relay-2, -3 harness connectors and cooling fan motor-1, -2 har-
ness connectors.
3. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 9.
NO
>> GO TO 8.
8.
DETECT MALFUNCTIONING PART
Check the following.
• Harness connector E12, E203
• Harness for open or short between cooling fan motor-1 and cooling fan relay-2
• Harness for open or short between cooling fan motor-1 and cooling fan relay-3
• Harness for open or short between cooling fan motor-2 and cooling fan relay-2
• Harness for open or short between cooling fan motor-2 and cooling fan relay-3
>> Repair open circuit, short to ground or short to power in harness or connectors.
9.
CHECK COOLING FAN MOTOR CIRCUIT-II
1. Check the continuity between IPDM E/R harness connector and cooling fan motor-1, -2 harness connec-
tor.
2. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 11.
NO
>> GO TO 10.
10.
DETECT MALFUNCTIONING PART
Check the following.
• Harness connector E12, E203
• Harness for open or short between cooling fan motor-1 and IPDM E/R
• Harness for open or short between cooling fan motor-2 and IPDM E/R
Cooling fan relay
Cooling fan motor
Continuity
Connector
Terminal
Connector
Terminal
E42
(cooling fan relay-2)
3
E221
(Cooling fan motor-2)
2
Existed
7
E220
(Cooling fan motor-1)
3
E43
(cooling fan relay-3)
3
E221
(Cooling fan motor-2)
1
7
E220
(Cooling fan motor-1)
4
IPDM E/R
Cooling fan motor
Continuity
Connector
Terminal
Connector
Terminal
E18
35
E220
(Cooling fan motor-1)
4
Existed
38
E221
(Cooling fan motor-2)
1
COOLING FAN
EC-459
< COMPONENT DIAGNOSIS >
[QR25DE FOR CALIFORNIA]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
>> Repair open circuit, short to ground or short to power in harness or connectors.
11.
CHECK COOLING FAN MOTOR CIRCUIT-III
1. Check the continuity between cooling fan relay-2, -3 harness connectors and ground.
2. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 12.
NO
>> Repair open circuit, short to ground or short to power in harness or connectors.
12.
CHECK COOLING FAN MOTOR CIRCUIT-IV
1. Check the continuity between cooling fan motor-2 harness connector and ground.
2. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 13.
NO
>> Repair open circuit, short to ground or short to power in harness or connectors.
13.
CHECK COOLING FAN RELAY-2 AND -3
EC-460, "Component Inspection (Cooling Fan Relay)"
Is the inspection result normal?
YES
>> GO TO 14.
NO
>> Replace malfunctioning cooling fan relay.
14.
CHECK COOLING FAN MOTORS-1 AND -2
EC-459, "Component Inspection (Cooling Fan Motor)"
Is the inspection result normal?
YES
>> GO TO 15.
NO
>> Replace malfunctioning cooling fan motor.
15.
CHECK INTERMITTENT INCIDENT
Perform
GI-42, "Intermittent Incident"
.
Is the inspection result normal?
YES
>> Replace IPDM E/R.
NO
>> Repair or replace harness connectors.
Component Inspection (Cooling Fan Motor)
INFOID:0000000004349519
1.
CHECK COOLING FAN MOTOR
1. Turn ignition switch OFF.
2. Disconnect cooling fan motor harness connector.
Cooling fan motor
Ground
Continuity
Connector
Terminal
E42
(cooling fan relay-2)
6
Ground
Existed
E43
(cooling fan relay-3)
6
Cooling fan motor-2
Ground
Continuity
Connector
Terminal
E221
3
Ground
Existed
4
EC-460
< COMPONENT DIAGNOSIS >
[QR25DE FOR CALIFORNIA]
COOLING FAN
3. Supply cooling fan motor terminals with battery voltage and
check operation.
Check that cooling fan speed of condition B is higher than that of A.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace cooling fan motor.
Component Inspection (Cooling Fan Relay)
INFOID:0000000004349520
1.
CHECK COOLING FAN RELAYS
1. Turn ignition switch OFF.
2. Remove cooling fan relay.
3. Check the continuity between cooling fan relay terminals under
the following conditions.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace cooling fan relay.
Condition
Terminals
+
−
Cooling fan motor
A
1
3 and 4
2
3 and 4
1 and 2
3
1 and 2
4
B
1, 2
3, 4
SEF734W
Terminals
Conditions
Continuity
3 and 5
12V direct current supply between terminals 1 and 2
Existed
No current supply
Not existed
6 and 7
12V direct current supply between terminals 1 and 2
Existed
No current supply
Not existed
PBIB0439E