Nissan Altima L32. Instruction — part 799
HA-16
< PREPARATION >
PREPARATION
Commercial Service Tool
INFOID:0000000004205487
—
(J-43872)
Refrigerant dye cleaner
For cleaning dye spills.
—
(J-39183-C)
Manifold gauge set (with hoses
and couplers)
Identification:
• The gauge face indicates R-134a.
Fitting size: Thread size
• 1/2” -16 ACME
Service hoses
• (J-39500-72B)
High side hose
• (J-39500-72R)
Low side hose
• (J-39500-72Y)
Utility hose
Hose color:
• Low side hose: Blue with black stripe
• High side hose: Red with black stripe
• Utility hose: Yellow with black stripe
or green with black stripe
Hose fitting to gauge:
• 1/2” -16 ACME
Service couplers
• (J-39500-20A)
High side coupler
• (J-39500-24A)
Low side coupler
Hose fitting to service hose:
• M14 x 1.5 fitting is optional or perma-
nently attached.
—
(J-39649)
Vacuum pump
(Including the isolator valve)
Capacity:
• Air displacement: 4 CFM
• Micron rating: 20 microns
• Oil capacity: 482 g (17 oz)
Fitting size: Thread size
• 1/2” -16 ACME
Tool number
(Kent-Moore No.)
Tool name
Description
SHA441F
RJIA0196E
S-NT201
S-NT202
S-NT203
PREPARATION
HA-17
< PREPARATION >
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
Tool number
Tool name
Description
J-41810-NI
Refrigerant identifier equipment
HFC 134a (R-134a)
Checking refrigerant purity and system
contamination
Power tool
Removing bolts, screws and nuts
RJIA0197E
PIIB1407E
HA-18
< FUNCTION DIAGNOSIS >
REFRIGERATION SYSTEM
FUNCTION DIAGNOSIS
REFRIGERATION SYSTEM
Refrigerant Cycle
INFOID:0000000004205488
Refrigerant flow
The refrigerant flows in the standard pattern, that is, through the compressor, the condenser with liquid tank,
through the evaporator, and back to the compressor. The refrigerant evaporation through the evaporator coil is
controlled by an externally equalized expansion valve, located inside the evaporator case.
Refrigerant System Protection
INFOID:0000000004205489
Refrigerant pressure sensor
The refrigerant system is protected against excessively high or low pressures by the refrigerant pressure sen-
sor, located on the condenser. If the system pressure rises above or falls below the specifications, the refriger-
ant pressure sensor detects the pressure inside the refrigerant line and sends the voltage signal to the ECM.
The ECM then ceases to supply power to the A/C relay which disengages and stops the compressor when
pressure on the high pressure side (as detected by refrigerant pressure sensor) is over approximately 2,746
kPa (28 kg/cm
2
, 398 psi), or below approximately 120 kPa (1.22 kg/cm
2
, 17.4 psi).
Pressure Relief Valve
The refrigerant system is also protected by a pressure relief valve, located in the rear head of the compressor.
When the pressure of refrigerant in the system increases to an abnormal level [more than 3,727 kPa (38 kg/
cm
2
, 540 psi)], the release port on the pressure relief valve automatically opens and releases refrigerant into
the atmosphere.
LJIA0015E
REFRIGERATION SYSTEM
HA-19
< FUNCTION DIAGNOSIS >
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
Component Part Location
INFOID:0000000004205490
1.
Heater and cooling unit assembly
2.
High-pressure pipe
3.
High-pressure A/C service valve
4.
Junction pipe
5.
High-pressure flexible hose
6.
Condenser and liquid tank
7.
Air deflector RH (QR25DE shown,
VQ35DE similar)
8.
Air deflector LH (QR25DE shown,
VQ35DE similar)
9.
Refrigerant pressure sensor
10. Low-pressure flexible hose
11. Low-pressure A/C service valve
12. Low-pressure pipe
ALIIA0001GB