PCS-68
< COMPONENT DIAGNOSIS >
[POWER DISTRIBUTION SYSTEM]
B2615 BLOWER RELAY CIRCUIT
B2615 BLOWER RELAY CIRCUIT
Description
INFOID:0000000004202453
BCM controls the various electrical components and simultaneously supplies power according to the power
supply position.
BCM checks the power supply position internally.
DTC Logic
INFOID:0000000004202454
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PERFORM DTC CONFIRMATION PROCEDURE
1. Turn ignition switch ON under the following conditions, and wait for at least 1 second.
-
CVT selector lever is in the P or N position.
-
Release brake pedal.
2. Check “Self diagnostic result” with CONSULT-III.
Is DTC detected?
YES
>> Go to
NO
>> Inspection End.
Diagnosis Procedure
INFOID:0000000004202455
1.
CHECK BLOWER RELAY POWER SUPPLY
1. Turn ignition switch OFF.
2. Disconnect blower relay.
3. Check voltage between blower relay harness connector and
ground under the following conditions.
Is the inspection result normal?
YES
>> GO TO 3
NO
>> GO TO 2
2.
CHECK BLOWER RELAY POWER SUPPLY CIRCUIT
DTC No.
Trouble diagnosis
name
DTC detecting condition
Possible cause
B2615
Blower relay circuit
BCM detects a difference of signal for 1 second or
more between the following information.
• Blower relay ON/OFF request
• Blower relay feedback
• Harness or connectors
(Blower relay circuit is open or
shorted)
• Blower relay
Blower relay
Ground
Condition
Voltage (V)
Terminal
2
Ground
OFF or ACC
0
ON
Battery voltage
ALMIA0450ZZ
PCS
B2615 BLOWER RELAY CIRCUIT
PCS-69
< COMPONENT DIAGNOSIS >
[POWER DISTRIBUTION SYSTEM]
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
1. Turn ignition switch OFF.
2. Disconnect BCM harness connector.
3. Check continuity between blower relay harness connector (A)
and BCM harness connector (B).
4. Check continuity between blower relay harness connector (A)
and ground.
Is the inspection result normal?
YES
>> GO TO 6
NO
>> Repair or replace harness.
3.
CHECK BLOWER RELAY GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Check continuity between blower relay harness connector and
ground.
Is the inspection result normal?
YES
>> GO TO 4
NO
>> Repair blower relay ground circuit.
4.
CHECK BLOWER RELAY POWER SUPPLY CIRCUIT-2
Check voltage between blower relay harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 5
NO
>> Repair or replace harness.
5.
CHECK BLOWER RELAY
PCS-70, "Component Inspection (Blower Relay)"
Is the inspection result normal?
YES
>> GO TO 6
NO
>> Replace blower relay.
6.
CHECK INTERMITTENT INCIDENT
GI-42, "Intermittent Incident"
.
>> Inspection End.
Blower relay
BCM
Continuity
Terminal
Connector
Terminal
2
M19
90
Yes
Blower relay
Ground
Continuity
Terminal
2
Ground
No
ALMIA0451ZZ
Blower relay
Ground
Continuity
Terminal
1
Ground
Yes
ALMIA0445ZZ
Blower relay
Ground
Voltage (V)
Terminal
3
Ground
Battery voltage
ALMIA0441ZZ
PCS-70
< COMPONENT DIAGNOSIS >
[POWER DISTRIBUTION SYSTEM]
B2615 BLOWER RELAY CIRCUIT
Component Inspection (Blower Relay)
INFOID:0000000004202456
1.
CHECK BLOWER RELAY
1. Turn ignition switch OFF.
2. Remove blower relay.
3. Check the continuity between blower relay terminals under the
following conditions.
Is the inspection result normal?
YES
>> Inspection End.
NO
>> Replace blower relay.
Terminals
Condition
Continuity
3 and 5
12V direct current supply between terminals 1 and 2
Yes
No current supply
No
PBIB0098E
PCS
B2616 IGNITION RELAY CIRCUIT
PCS-71
< COMPONENT DIAGNOSIS >
[POWER DISTRIBUTION SYSTEM]
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
B2616 IGNITION RELAY CIRCUIT
Description
INFOID:0000000004202457
BCM controls the various electrical components and simultaneously supplies power according to the power
supply position.
BCM checks the power supply position internally.
DTC Logic
INFOID:0000000004202458
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PERFORM DTC CONFIRMATION PROCEDURE
1. Turn ignition switch ON under the following conditions, and wait for at least 1 second.
-
CVT selector lever is in the P or N position
-
Release brake pedal
2. Check “Self diagnostic result” with CONSULT-III.
Is DTC detected?
YES
>> Go to
NO
>> Inspection End.
Diagnosis Procedure
INFOID:0000000004202459
1.
CHECK IGNITION RELAY POWER SUPPLY
1. Turn ignition switch OFF.
2. Disconnect ignition relay.
3. Check voltage between ignition relay harness connector and
ground under the following conditions.
Is the inspection result normal?
YES
>> GO TO 3
NO
>> GO TO 2
2.
CHECK IGNITION RELAY POWER SUPPLY CIRCUIT
DTC No.
Trouble diagnosis
name
DTC detecting condition
Possible cause
B2616
Ignition relay circuit
An immediate operation of ignition relay (fuse
block) is requested by BCM, but there is no re-
sponse for more than 1 second
• Harness or connectors
(Ignition relay circuit is open or
shorted)
• Ignition relay (Fuse block)
Ignition relay
Ground
Condition
Voltage (V)
Terminal
1
Ground
Ignition switch OFF
or ACC
0
Ignition switch ON
Battery voltage
ALMIA0446ZZ