Nissan Altima L32. Instruction — part 1112
DOOR KEY CYLINDER SWITCH
PWC-215
< COMPONENT DIAGNOSIS >
[LH&RH FRONT ANTI-PINCH-COUPE]
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
1. Turn ignition switch OFF.
2. Disconnect main power window and door lock/unlock switch and
door lock assembly LH (key cylinder switch).
3. Check continuity between main power window and door lock/
unlock switch connector (A) and door lock assembly LH (key cyl-
inder switch) connector (B).
4. Check continuity between main power window and door lock/unlock switch connector (A) and ground.
Is the inspection result normal?
YES
>> GO TO 3
NO
>> Repair or replace harness.
3.
CHECK DOOR KEY CYLINDER SWITCH GROUND CIRCUIT
Check continuity between door lock assembly LH (key cylinder
switch) connector and ground.
Is the inspection result normal?
YES
>> GO TO 4
NO
>> Repair or replace harness.
4.
CHECK DOOR KEY CYLINDER SWITCH
Check door key cylinder switch.
PWC-215, "Component Inspection"
.
Is the inspection result normal?
YES
>> Check intermittent incident. Refer to
GI-42, "Intermittent Incident"
.
NO
>> Replace door lock assembly LH (door key cylinder switch). After that, refer to
.
Component Inspection
INFOID:0000000004205107
COMPONENT INSPECTION
1.
CHECK DOOR KEY CYLINDER SWITCH
Main power window
and door lock/unlock
switch connector
Terminal
Door lock assembly
LH (key cylinder
switch) connector
Terminal
Continuity
D7 (A)
6
D10 (B)
6
Yes
7
5
Main power window and door
lock/unlock switch connector
Terminal
Ground
Continuity
D7 (A)
6
No
7
ALKIA1353ZZ
Door lock assembly LH (key cyl-
inder switch) connector
Terminal
Ground
Continuity
D10
4
Yes
ALKIA0348ZZ
PWC-216
< COMPONENT DIAGNOSIS >
[LH&RH FRONT ANTI-PINCH-COUPE]
DOOR KEY CYLINDER SWITCH
Check door lock assembly LH (key cylinder switch).
Is the inspection result normal?
YES
>> Key cylinder switch is OK.
NO
>> Replace door lock assembly LH (key cylinder switch). After that, refer to
.
Special Repair Requirement
INFOID:0000000004205108
1.
PERFORM INITIALIZATION PROCEDURE
Perform initialization procedure.
Refer to
PWC-190, "ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Special
.
Is the inspection result normal?
YES
>> Inspection End.
NO
>> Check intermittent incident. Refer to
GI-42, "Intermittent Incident"
.
Terminal
Key position
Continuity
Door lock assembly LH (key
cylinder switch) connector
5
4
Unlock
Yes
Neutral/Lock
No
6
Lock
Yes
Neutral/Unlock
No
ALKIA0312ZZ
POWER WINDOW SERIAL LINK
PWC-217
< COMPONENT DIAGNOSIS >
[LH&RH FRONT ANTI-PINCH-COUPE]
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
POWER WINDOW SERIAL LINK
POWER WINDOW MAIN SWITCH
POWER WINDOW MAIN SWITCH : Description
INFOID:0000000004205109
Main power window and door lock/unlock switch, power window and door lock/unlock switch RH and BCM
transmit and receive the signal by power window serial link.
The signal mentioned below is transmitted from BCM to main power window and door lock/unlock switch and
power window and door lock/unlock switch RH
• Keyless power window down signal
The signal mentioned below is transmitted from main power window and door lock/unlock switch to power win-
dow and door lock/unlock switch RH
• Door window RH operation signal
• Power window control by key cylinder switch signal
• Power window lock switch signal
• Retained power operation signal
POWER WINDOW MAIN SWITCH : Component Function Check
INFOID:0000000004205110
1.
CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH OUTPUT SIGNAL
Check (“CDL LOCK SW ”, “CDL UNLOCK SW”) in “DATA MONITOR” mode for “POWER DOOR LOCK SYS-
TEM” with CONSULT-III. Refer to
BCS-19, "DOOR LOCK : CONSULT-III Function (BCM - DOOR LOCK)"
.
Is the inspection result normal?
YES
>> Power window serial link is OK.
NO
>> Refer to
PWC-217, "POWER WINDOW MAIN SWITCH : Diagnosis Procedure"
POWER WINDOW MAIN SWITCH : Diagnosis Procedure
INFOID:0000000004205111
Power Window Serial Link Check
1.
CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH OUTPUT SIGNAL
1. Remove Intelligent Key, and close front door LH and RH.
2. Check signal between BCM connector and ground with oscillo-
scope when door lock and unlock switch (LH and RH) is turned
to “LOCK” or “UNLOCK”.
3. Check that signals which are shown in the figure below can be
detected during 10 second just after door lock and unlock switch
(LH and RH) is turned to “LOCK” or “UNLOCK”.
Monitor item
Condition
CDL LOCK SW
LOCK
: ON
UNLOCK
: OFF
CDL UNLOCK SW
LOCK
: OFF
UNLOCK
: ON
ALKIA0313ZZ
PWC-218
< COMPONENT DIAGNOSIS >
[LH&RH FRONT ANTI-PINCH-COUPE]
POWER WINDOW SERIAL LINK
Is the inspection result normal?
YES
>> Power window serial link is OK.
NO
>> GO TO 2
2.
CHECK POWER WINDOW SERIAL LINK CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM and main power window and door lock/unlock
switch.
3. Check continuity between BCM connector (A) and main power
window and door lock/unlock switch connector (B).
4. Check continuity between BCM connector (A) and ground.
Is the inspection result normal?
YES
>> Replace main power window and door lock/unlock switch. Refer to
PWC-199, "POWER WINDOW MAIN SWITCH : Special Repair
NO
>> Repair or replace harness.
PASSENGER SIDE
PASSENGER SIDE : Description
INFOID:0000000004205112
Main power window and door lock/unlock switch, power window and door lock/unlock switch RH and BCM
transmit and receive the signal by power window serial link.
The signal mentioned below is transmitted from BCM to main power window and door lock/unlock switch and
power window and door lock/unlock switch RH
• Keyless power window down signal
The signal mentioned below is transmitted from main power window and door lock/unlock switch to power win-
dow and door lock/unlock switch RH
• Door window RH operation signal
• Power window control by key cylinder switch signal
• Retained power operation signal
• Power window lock switch signal
PASSENGER SIDE : Component Function Check
INFOID:0000000004205113
1.
CHECK POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH OUTPUT SIGNAL
Terminal
Signal
(Reference value)
(+)
(–)
BCM connector
Terminal
M18
40
Ground
PIIA1297E
BCM connector
Terminal
Main power window and door
lock/unlock switch connector
Terminal
Continuity
M18 (A)
40
D7 (B)
12
Yes
ALKIA1345ZZ
BCM connector
Terminal
Ground
Continuity
M18 (A)
40
No
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст