Nissan Altima L32. Instruction — part 548
P0442 EVAP CONTROL SYSTEM
EC-1313
< COMPONENT DIAGNOSIS >
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
Remove EVAP canister with EVAP canister vent control valve and
EVAP control system pressure sensor attached.
Does water drain from the EVAP canister?
YES
>> GO TO 8.
NO-1 >> With CONSULT-III: GO TO 10.
NO-2 >> Without CONSULT-III: GO TO 11.
8.
CHECK EVAP CANISTER
Weigh the EVAP canister with the EVAP canister vent control valve and EVAP control system pressure sensor
attached.
The weight should be less than 2.1 kg (4.6 lb).
Is the inspection result normal?
YES-1 >> With CONSULT-III: GO TO 10.
YES-2 >> Without CONSULT-III: GO TO 11.
NO
>> GO TO 9.
9.
DETECT MALFUNCTIONING PART
Check the following.
• EVAP canister for damage
• EVAP hose between EVAP canister and vehicle frame for clogging or poor connection
>> Repair hose or replace EVAP canister.
10.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
With CONSULT-III
1. Disconnect vacuum hose from EVAP canister purge volume control solenoid valve at EVAP service port.
2. Start engine.
3. Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode.
4. Touch “Qu” on CONSULT-III screen to increase “PURG VOL CONT/V” opening to 100%.
5. Check vacuum hose for vacuum.
Is the inspection result normal?
YES
>> GO TO 13.
NO
>> GO TO 12.
11.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
Without CONSULT-III
1. Start engine and warm it up to normal operating temperature.
2. Stop engine.
3. Disconnect vacuum hose from EVAP canister purge volume control solenoid valve at EVAP service port.
4. Start engine and let it idle for at least 80 seconds.
5. Check vacuum hose for vacuum when revving engine up to 2,000 rpm.
Is the inspection result normal?
YES
>> GO TO 13.
NO
>> GO TO 12.
12.
CHECK VACUUM HOSE
Check vacuum hoses for clogging or disconnection. Refer to
Is the inspection result normal?
PBIB1213E
Vacuum should exist.
Vacuum should exist.
EC-1314
< COMPONENT DIAGNOSIS >
[VQ35DE]
P0442 EVAP CONTROL SYSTEM
YES
>> GO TO 13.
NO
>> Repair or reconnect the hose.
13.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-1319, "Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 14.
NO
>> Replace EVAP canister purge volume control solenoid valve.
14.
CHECK FUEL TANK TEMPERATURE SENSOR
EC-1276, "Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 15.
NO
>> Replace fuel level sensor unit and fuel pump.
15.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
EC-1334, "Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 16.
NO
>> Replace EVAP control system pressure sensor.
16.
CHECK EVAP PURGE LINE
Check EVAP purge line (pipe, rubber tube, fuel tank and EVAP canister) for cracks or improper connection.
Is the inspection result normal?
YES
>> GO TO 17.
NO
>> Repair or reconnect the hose.
17.
CLEAN EVAP PURGE LINE
Clean EVAP purge line (pipe and rubber tube) using air blower.
>> GO TO 18.
18.
CHECK EVAP/ORVR LINE
Check EVAP/ORVR line between EVAP canister and fuel tank for clogging, kinks, looseness and improper
connection. For location, refer to
.
Is the inspection result normal?
YES
>> GO TO 19.
NO
>> Repair or replace hoses and tubes.
19.
CHECK RECIRCULATION LINE
Check recirculation line between fuel filler tube and fuel tank for clogging, kinks, cracks, looseness and
improper connection.
Is the inspection result normal?
YES
>> GO TO 20.
NO
>> Repair or replace hose, tube or fuel filler tube.
20.
CHECK REFUELING EVAP VAPOR CUT VALVE
EC-1500, "Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 21.
NO
>> Replace refueling EVAP vapor cut valve with fuel tank.
21.
CHECK FUEL LEVEL SENSOR
MWI-47, "Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 22.
P0442 EVAP CONTROL SYSTEM
EC-1315
< COMPONENT DIAGNOSIS >
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
NO
>> Replace fuel level sensor unit and fuel pump.
22.
CHECK INTERMITTENT INCIDENT
GI-42, "Intermittent Incident"
.
>> INSPECTION END
Component Inspection
INFOID:0000000004362156
1.
CHECK FUEL FILLER CAP
1. Turn ignition switch OFF.
2. Remove fuel filler cap.
3. Wipe clean valve housing.
4. Install fuel filler cap adapter (commercial service tool) to fuel filler cap.
5. Check valve opening pressure and vacuum.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> GO TO 2.
2.
REPLACE FUEL FILLER CAP
Replace fuel filler cap.
CAUTION:
Use only a genuine fuel filler cap as a replacement. If an incorrect fuel filler cap is used, the MIL may
illuminate.
>> INSPECTION END
SEF445Y
Pressure: 15.3 - 20.0 kPa (0.156 - 0.204 kg/cm
2
, 2.22 -
2.90 psi)
Vacuum:
−6.0 to −3.3 kPa (−0.061 to −0.034 kg/cm
2
,
−0.87 to −0.48 psi)
SEF943S
EC-1316
< COMPONENT DIAGNOSIS >
[VQ35DE]
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Description
INFOID:0000000004362157
The EVAP canister purge volume control solenoid valve is used to
control the flow rate of fuel vapor from the EVAP canister. The EVAP
canister purge volume control solenoid valve is moved by ON/OFF
pulses from the ECM. The longer the ON pulse, the greater the
amount of fuel vapor that will flow via the valve.
DTC Logic
INFOID:0000000004362158
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following before conduct-
ing the next test.
1. Turn ignition switch OFF and wait at least 10 seconds.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
Always perform test at a temperature of 5
°C (41°F) or more.
Will CONSULT-III be used?
YES
>> GO TO 2.
NO
>> GO TO 3.
2.
PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT-III
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON.
4. Turn ignition switch OFF and wait at least 10 seconds.
5. Turn ignition switch ON.
6. Select “PURG VOL CN/V P1444” of “EVAPORATIVE SYSTEM” in “DTC WORK SUPPORT” mode with
CONSULT-III.
7. Touch “START”.
8. Start engine and let it idle until “TESTING” on CONSULT-III changes to “COMPLETED”. (It will take
approximately 10 seconds.)
If “TESTING” is not displayed after 5 minutes, retry from step 2.
9. Touch “SELF-DIAG RESULTS”.
Which is displayed on CONSULT-III screen?
PBIB3489E
DTC No.
Trouble diagnosis name
DTC detecting condition
Possible cause
P0443
EVAP canister purge
volume control solenoid
valve
The canister purge flow is detected during the
specified driving conditions, even when EVAP
canister purge volume control solenoid valve is
completely closed.
• EVAP control system pressure sensor
• EVAP canister purge volume control so-
lenoid valve
(The valve is stuck open.)
• EVAP canister vent control valve
• EVAP canister
• Hoses
(Hoses are connected incorrectly or
clogged.)