Nissan Terrano model r20 series 2004. Instruction — part 359
Gauge indication
Refrigerant cycle
Probable cause
Corrective action
Low-pressure side becomes
negative.
AC362A
Liquid tank or front/rear side of
expansion valve’s pipe is
frosted or dewed.
High-pressure side is closed
and refrigerant does not flow.
"
Expansion valve or liquid tank
is frosted.
After the system is left at rest,
start it again in order to con-
firm whether or not problem is
caused by water or foreign
particles.
I
If the problem is due to
water, drain water from
refrigerant or replace refrig-
erant.
I
If it is due to foreign
particles, remove expansion
valve and remove them with
dry and compressed air.
I
If either of the above meth-
ods cannot correct the
problem, replace expansion
valve.
I
Replace liquid tank.
I
Check compressor oil for
contamination.
DIAGNOSES — Overall System
Performance Test Diagnoses (Cont’d)
HA-36
Symptom Chart
DIAGNOSTIC TABLE
PROCEDURE
Prelimi-
nary
Check
Diagnostic
Procedure
Main Power
Supply and
Ground Circuit
Check
Electrical Components Inspection
SYMPTOM
Preliminary
check
1
Preliminary
check
2
Diagnostic
procedure
1
Diagnostic
procedure
2
Diagnostic
procedure
3
15A
Fuses
10A
Fuse
15A
Fuse
Blower
motor
Intake
door
motor
Resistor
A/C
switch
Fan
switch
A/C
relay
Dual-pressure
switch
Compressor
Harness
Magnet
clutch
A/C does not blow cold air.
q
q
q
q
q
q
q
q
q
q
q
q
Blower motor does not rotate.
q
q
q
q
q
q
Magnet clutch does not
engage when A/C switch and
fan switch are ON.
q
q
q
q
q
q
q
q
Noise
Intake door does not change.
q
q
q
,
: The number indicates checking order.
q
: Refer to each flow chart for checking order. (It depends on malfunctioning portion.)
TROUBLE DIAGNOSES
HA-37
Preliminary Check
PRELIMINARY CHECK 1
A/C does not blow cold air.
DOES AIR FLOW FROM VENTS?
Condition
I
Ignition switch, A/C switch, and
fan switch are ON.
I
Mode lever is in VENT mode
and temperature lever is in full
cold position.
OK
E
NG
IS BLOWER MOTOR OPERAT-
ING NORMALLY?
Yes
No
CHECK
BLOWER
MOTOR
OPERATION.
Go to Diagnos-
tic Procedure
1.
CHECK COMPRESSOR BELT TEN-
SION.
Refer to MA section.
NG
OK
F
NG
CHECK COMPRESSOR OPERA-
TION.
OK
CHECK FOR EVAPORATOR COIL
FREEZE UP.
Remove intake unit. Check if
evaporator freezes.
NG
(Freezes up)
OK
(Does not
freeze up)
Adjust or
replace com-
pressor belt.
CHECK REFRIGERATION CYCLE
PRESSURE WITH RECOVERY/
RECYCLING EQUIPMENT CON-
NECTED.
Refer to Performance Chart,
HA-31.
NG
OK
CHECK VENTI-
LATOR DUCT
FOR AIR
LEAKS.
CHECK AMOUNT OF
REFRIGERANT.
Check amount of refrigerant using
ACR4 (Refrigerant recovery &
recharging equipment).
OK
NG
Go to Perfor-
mance Test
Diagnoses.
CHECK THERMO CONTROL
AMP. OPERATION.
Refer to Electrical Components
Inspection, HA-62.
Evacuate sys-
tem and
recharge with
refrigerant.
CHECK FOR
REFRIGERANT
LEAKS.
Go to Diagnostic Procedures 2.
CHECK AIR CONTROL CABLE
ADJUSTMENT.
Refer to Control Linkage
Adjustment, HA-64.
F
OK
CHECK EVAPORATOR OUTLET
AIR TEMPERATURE.
Refer to Performance Chart,
HA-31.
NG
CHECK THERMO CONTROL
AMP. OPERATION.
Refer to Electrical Components
Inspection, HA-62.
H
H
H
H
H
H
H
H
H
H
H
H
H
H
TROUBLE DIAGNOSES
HA-38
PRELIMINARY CHECK 2
Noise
Check where noise
comes from.
Expansion valve
Compressor
Refrigerant line
Belt
Replace expan-
sion valve.
Replace com-
pressor.
The line is fixed directly
to the body.
The line is not fixed.
Fix the line with rubber
or some vibration
absorbing material.
Fix the line tightly.
The belt vibration is
intense.
Side of belt is worn
out.
Readjust belt tension.
Refer to ENGINE MAIN-
TENANCE in MA sec-
tion.
The pulley center
does not match.
Readjust the pulley
center.
H
H
H
H
H
H
H
H
H
H
H
H
H
H
TROUBLE DIAGNOSES
Preliminary Check (Cont’d)
HA-39