Nissan Murano Z51. Instruction — part 1022

MIR-44

< ECU DIAGNOSIS INFORMATION >

[WITH ADP]

AUTOMATIC DRIVE POSITIONER CONTROL UNIT

AUTOMATIC DRIVE POSITIONER CONTROL UNIT

Reference Value

INFOID:0000000005712158

TERMINAL LAYOUT

PHYSICAL VALUES

JMJIA1389ZZ

Terminal No.

(wire color)

Description

Condition

Voltage (V)

(Approx.)

+

-

Signal name

Input/

Output

1

(Y)

Ground

Tilt switch up signal

Input

Tilt switch

Operate
(up)

0

Other than
above

5

2

(GR)

Ground

Changeover switch RH
signal

Input

Changeover
switch position

RH

0

Neutral or
LH

5

3

(SB)

Ground

Mirror switch up signal

Input

Mirror switch

Operated
(up)

0

Other than
above

5

4

(LG)

Ground

Mirror switch left signal

Input

Mirror switch

Operated
(left)

0

Other than
above

5

5

(R)

Ground

Door mirror sensor (pas-
senger side) up/down
signal

Input

Door mirror RH position

Change between 3.4 (close to

peak) 0.6 (close to valley)

6

(Y)

Ground

Door mirror sensor (driv-
er side) up/down signal

Input

Door mirror LH position

Change between 3.4 (close to

peak) 0.6 (close to valley)

7

(P)

Ground

Telescopic switch for-
ward signal

Input

Telescopic
switch

Operate
(forward)

0

Other than
above

5

8

(LG)

Ground

UART communication
(TX/RX)

Output

Ignition switch ON

JMJIA1391ZZ

AUTOMATIC DRIVE POSITIONER CONTROL UNIT

MIR-45

< ECU DIAGNOSIS INFORMATION >

[WITH ADP]

C

D

E

F

G

H

I

J

K

M

A

B

MIR

N

O

P

10

(O)

Ground

Door mirror motor (pas-
senger side) up output
signal

Output

Door mirror RH

Operate
(up)

Battery voltage

Other than
above

0

11

(G)

Ground

Door mirror motor (pas-
senger side) left output
signal

Output

Door mirror RH

Operate
(left)

Battery voltage

Other than
above

0

12

(R)

Ground

Door mirror motor (driv-
er side) down output sig-
nal

Output

Door mirror (LH)

Operate
(down)

Battery voltage

Other than
above

0

Door mirror motor (driv-
er side) right output sig-
nal

Operate
(right)

Battery voltage

Other than
above

0

13

(LG)

Ground

Tilt switch down signal

Input

Tilt switch

Operate
(down)

0

Other than
above

5

14

(O)

Ground

Changeover switch LH
signal

Input

Changeover
switch position

LH

0

Neutral or
RH

5

15

(L)

Ground

Mirror switch down sig-
nal

Input

Mirror switch

Operate
(down)

0

Other than
above

5

16

(V)

Ground

Mirror switch right signal

Input

Mirror switch

Operate
(right)

0

Other than
above

5

17

(W)

Ground

Door mirror sensor (pas-
senger side) left/right
signal

Input

Door mirror RH position

Change between 3.4 (close to left

edge) 0.6 (close to right edge)

18

(L)

Ground

Door mirror sensor (driv-
er side) left/right signal

Input

Door mirror LH position

Change between 0.6 (close to left

edge) 3.4 (close to right edge)

19

(G)

Ground

Telescopic switch back-
ward signal

Input

Telescopic
switch

Operate
(back-
ward)

0

Other than
above

5

20

(Y)

Ground

Ground

0

21

(W)

Ground

Door mirror motor sen-
sor power supply

Input

5

Terminal No.

(wire color)

Description

Condition

Voltage (V)

(Approx.)

+

-

Signal name

Input/

Output

MIR-46

< ECU DIAGNOSIS INFORMATION >

[WITH ADP]

AUTOMATIC DRIVE POSITIONER CONTROL UNIT

22

(V)

Ground

Door mirror motor (pas-
senger side) down out-
put signal

Output

Door mirror (RH)

Operate
(down)

Battery voltage

Other than
above

0

Door mirror motor (pas-
senger side) right output
signal

Operate
(right)

Battery voltage

Other than
above

0

23

(L)

Ground

Door mirror motor (driv-
er side)up output signal

Output

Door mirror (LH)

Operate
(up)

Battery voltage

Other than
above

0

24

(SB)

Ground

Door mirror motor (driv-
er side)left output signal

Output

Door mirror (LH)

Operate
(left)

Battery voltage

Other than
above

0

25

(W)

Ground

Power source

Input

Battery voltage

26

(L)

Ground

Telescopic motor back-
ward output signal

Output

Steering tele-
scopic

Operate
(back-
ward)

Battery voltage

Other than
above

0

27

(P)

Ground

Tilt&telescopic motor
power source

Battery voltage

28

(G)

Ground

Tilt motor down output
signal

Output

Steering tilt

Operate
(down)

Battery voltage

Other than
above

0

29

(LG)

Ground

Tilt motor up output sig-
nal

Output

Steering tilt

Operate
(up)

Battery voltage

Other than
above

0

Telescopic motor for-
ward output signal

Steering tele-
scopic

Operate
(forward)

Battery voltage

Other than
above

0

30

(B)

Ground

Ground

0

Terminal No.

(wire color)

Description

Condition

Voltage (V)

(Approx.)

+

-

Signal name

Input/

Output

AUTOMATIC DRIVE POSITIONER CONTROL UNIT

MIR-47

< ECU DIAGNOSIS INFORMATION >

[WITH ADP]

C

D

E

F

G

H

I

J

K

M

A

B

MIR

N

O

P

Wiring Diagram - AUTOMATIC DRIVE POSITIONER CONTROL SYSTEM -

INFOID:0000000005716145

JCJWM0709GB

Была ли эта страница вам полезна?
Да!Нет
9 посетителей считают эту страницу полезной.
Большое спасибо!
Ваше мнение очень важно для нас.

Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.

Текст

Политика конфиденциальности