Nissan Murano Z51. Instruction — part 631
EC-532
< PERIODIC MAINTENANCE >
[VQ35DE]
EVAP LEAK CHECK
EVAP LEAK CHECK
Inspection
INFOID:0000000005536915
CAUTION:
• Never use compressed air or a high pressure pump.
• Never exceed 4.12 kPa (0.042 kg/cm
2
, 0.6 psi) of pressure in EVAP system.
NOTE:
• Do not start engine.
• Improper installation of EVAP service port adapter (commercial service tool) to the EVAP service port may
cause a leakage.
WITH CONSULT-III
1.
To locate the EVAP leakage, install EVAP service port adapter
(commercial service tool) and pressure pump to EVAP service
port.
2.
Turn ignition switch ON.
3.
Select the “EVAP SYSTEM CLOSE” of “WORK SUPPORT
MODE” with CONSULT-III.
4.
Touch “START”. A bar graph (Pressure indicating display) will
appear on the screen.
5.
Apply positive pressure to the EVAP system until the pressure
indicator reaches the middle of the bar graph.
6.
Remove EVAP service port adapter (commercial service tool)
and hose with pressure pump.
7.
Locate the leakage using a leakage detector (commercial ser-
vice tool). Refer to
.
WITHOUT CONSULT-III
1.
To locate the EVAP leakage, install EVAP service port adapter
(commercial service tool) and pressure pump to EVAP service
port.
2.
Apply battery voltage between the terminals of EVAP canister
vent control valve to make a closed EVAP system.
3.
To locate the leakage, deliver positive pressure to the EVAP sys-
tem until pressure gauge points reach 1.38 to 2.76 kPa (0.014 to
0.028 kg/cm
2
, 0.2 to 0.4 psi).
4.
Remove EVAP service port adapter (commercial service tool)
and hose with pressure pump.
SEF462UA
SEF200U
SEF462UA
EVAP LEAK CHECK
EC-533
< PERIODIC MAINTENANCE >
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
5.
Locate the leakage using a leak detector (commercial service
tool). Refer to
SEF200U
EC-534
< REMOVAL AND INSTALLATION >
[VQ35DE]
EVAP CANISTER
REMOVAL AND INSTALLATION
EVAP CANISTER
Exploded View
INFOID:0000000005536916
Removal and Installation
INFOID:0000000005536917
REMOVAL
1.
Lift up the vehicle.
2.
Remove EVAP canister fixing bolt.
3.
Remove EVAP canister.
NOTE:
The EVAP canister vent control valve and EVAP canister system pressure sensor can be removed without
removing the EVAP canister.
INSTALLATION
Install in the reverse order of removal.
NOTE:
Tighten EVAP canister fixing bolt to the specified torque.
DISASSEMBLY
1.
Turn EVAP canister vent control valve counterclockwise.
2.
Remove the EVAP canister vent control valve.
ASSEMBLY
Assemble in the reverse order of disassembly.
CAUTION:
Always replace O-ring with a new one.
PBIB1383E
PBIB1384E
EVAP CANISTER
EC-535
< REMOVAL AND INSTALLATION >
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
Inspection
INFOID:0000000005536918
Check EVAP canister as per the following:
1.
Block port (B).
2.
Blow air into port (A) and check that it flows freely out of port (C).
3.
Release blocked port (B).
4.
Apply vacuum pressure to port (B) and check that vacuum pres-
sure exists at the ports (A) and (C).
5.
Block port (A) and (B).
6.
Apply pressure to port (C) and check that there is no leakage.
JMBIA1133ZZ