Nissan Silvia. Instruction — part 265
HFC-134a (R-134a) Service Tools and
Equipment
=NMHA0068
Never mix HFC-134a refrigerant and/or its specified lubricant with CFC-12 (R-12) refrigerant and/or its lubri-
cant.
Separate and non-interchangeable service equipment must be used for handling each type of refrigerant/
lubricant.
Refrigerant container fittings, service hose fittings and service equipment fittings (equipment which handles
refrigerant and/or lubricant) are different between CFC-12 (R-12) and HFC-134a (R-134a). This is to avoid
mixed use of the refrigerants/lubricant.
Adapters that convert one size fitting to another must never be used: refrigerant/lubricant contamination will
occur and compressor failure will result.
Tool number
(Kent-Moore No.)
Tool name
Description
HFC-134a (R-134a)
refrigerant
NT196
Container color: Light blue
Container marking: HFC-134a (R-134a)
Fitting size: Thread size
I
Large container 1/2
″
-16 ACME
KLH00-PAGR0
Nissan A/C System Oil
Type R
NT197
Type: Poly alkylene glycol oil (PAG), type R
Application: HFC-134a (R-134a) swash plate (pis-
ton) compressors (Nissan only)
Lubricity: 40 m
(1.4 US fl oz, 1.4 Imp fl oz)
Recovery/Recycling
Recharging equipment
(ACR4)
NT195
Function: Refrigerant Recovery and Recycling and
Recharging
Electrical leak detector
NT198
Power supply:
I
DC 12V (Cigarette lighter)
GI
MA
EM
LC
EC
FE
CL
MT
AT
PD
AX
SU
BR
ST
RS
BT
SC
EL
IDX
PREPARATION
HFC-134a (R-134a) Service Tools and Equipment
HA-11
Tool number
(Kent-Moore No.)
Tool name
Description
(J-43926)
Refrigerant dye leak
detection kit
Kit includes:
(J-42220) UV lamp and
UV safety glasses
(J-41459) Refrigerant
dye injector
(J-41447) qty. 24
R-134a refrigerant dye
(J-43872) Refrigerant
dye cleaner
SHA437F
Power supply:
DC 12V (Battery terminal)
(J-42220)
Fluorescent dye leak
detector
UV lamp
UV safety glasses
SHA438F
Power supply: DC12V (Battery terminal)
For checking refrigerant leak when fluorescent dye
is installed in A/C system.
Includes: UV lamp and UV safety glasses
(J-41447)
R134a Fluorescent Leak
Detection Dye (Box of
24, 1/4 ounce bottles)
Dye
SHA439F
Application: For R-134a PAG oil
Container: 1/4 ounce (7.4 cc) bottle
(Includes self-adhesive dye identification labels for
affixing to vehicle after charging system with dye.)
(J-41459)
R134a Dye Injector
Use with J-41447, 1/4
ounce bottle
Dye injector
SHA440F
For injecting 1/4 ounce of Fluorescent Leak Detec-
tion Dye into A/C system.
(J-43872)
Dye cleaner
SHA441F
For cleaning dye spills.
Manifold gauge set (with
hoses and couplers)
NT199
Identification:
I
The gauge face indicates R-134a.
Fitting size: Thread size
I
1/2
″
-16 ACME
PREPARATION
HFC-134a (R-134a) Service Tools and Equipment (Cont’d)
HA-12
Tool number
(Kent-Moore No.)
Tool name
Description
Service hoses
I
High side hose
I
Low side hose
I
Utility hose
NT201
Hose color:
I
Low hose: Blue with black stripe
I
High hose: Red with black stripe
I
Utility hose: Yellow with black stripe or green
with black stripe
Hose fitting to gauge:
I
1/2
″
-16 ACME
Service couplers
I
High side coupler
I
Low side coupler
NT202
Hose fitting to service hose:
I
M14 x 1.5 fitting is optional or permanently
attached.
Refrigerant weight scale
NT200
For measuring of refrigerant
Fitting size: Thread size
I
1/2
″
-16 ACME
Vacuum pump
(Including the isolator
valve)
NT203
Capacity:
I
Air displacement: 4 CFM
I
Micron rating: 20 microns
I
Oil capacity: 482 g (17 oz)
Fitting size: Thread size
I
1/2
″
-16 ACME
GI
MA
EM
LC
EC
FE
CL
MT
AT
PD
AX
SU
BR
ST
RS
BT
SC
EL
IDX
PREPARATION
HFC-134a (R-134a) Service Tools and Equipment (Cont’d)
HA-13
Refrigeration System
REFRIGERATION CYCLE
NMHA0069
Refrigerant Flow
NMHA0069S01
The refrigerant flows in the standard pattern, that is, through the compressor, the condenser, the liquid tank,
through the evaporator, and back to the compressor. The refrigerant evaporation through the evaporator coil
is controlled by an externally equalized expansion valve, located inside the evaporator case.
Refrigerant System Protection
NMHA0069S03
Dual-pressure Switch
NMHA0069S0303
The refrigerant system is protected against excessively high or low pressures by the dual-pressure switch,
located on the liquid tank. If the system pressure rises above or falls below the specifications, the dual-pres-
sure switch opens to interrupt the compressor operation.
Fusible Plug
NMHA0069S0304
Opens at temperatures above 105°C (221°F), thereby discharging refrigerant to the atmosphere. If this plug
is melted, check the refrigerant line and replace liquid tank.
ZHA086H
DESCRIPTION
Refrigeration System
HA-14