Nissan Primera P11. Instruction — part 291
2.
Convert into specific gravity at 20°C (68°F).
Example:
●
When electrolyte temperature is 35°C (95°F) and specific
gravity of electrolyte is 1.230, converted specific gravity at
20°C (68°F) is 1.240.
●
When electrolyte temperature is 0°C (32°F) and specific
gravity of electrolyte is 1.210, converted specific gravity at
20°C (68°F) is 1.196.
SEL007Z
Converted specific gravity
Electrolyte temperature °C (°F)
Specific
gravity
at
electrolyte
temperature
.
Freezing zone
(−22)
(−4)
(14)
(32)
(50)
(68)
(86)
(104)
(122)
BATTERY
How to Handle Battery (Cont’d)
EL-31
Battery Test and Charging Chart
Chart I
VISUAL INSPECTION
●
Check battery case for cracks or bends.
●
Check battery terminals for damage.
●
If the difference between the max. and min. electrolyte level in cells is within 10 mm (0.39 in), it is OK.
OK
NG
CHECKING SPECIFIC GRAVITY
Refer to “Specific Gravity Check”.
Replace
battery.
Below 1.100
1.100 - 1.220
Above 1.220
SLOW CHARGE
Refer to “A: Slow
Charge”.
*
STANDARD
CHARGE
Refer to “B: Standard
Charge”.
QUICK CHARGE
Refer to “C: Quick Charge”.
CAPACITY TEST
Refer to “Chart II”.
OK
NG
CAPACITY TEST
Refer to “Chart II”.
OK
NG
CAPACITY TEST
Refer to “Chart II”.
OK
NG
Ready for use
●
Mount battery again
and check loose ter-
minals. Also check
other related circuits.
Ready for
use
Replace
battery.
Ready for
use
CHECKING SPECIFIC
GRAVITY
Refer to “Specific Gravity
Check”.
QUICK CHARGE
Refer to “C: Quick Charge”.
●
Time required: 45 min.
RECHARGE
Refer to “C: Quick Charge”.
●
If battery temperature rises above 60°C (140°F),
stop charging. Always charge battery when its tem-
perature is below 60°C (140°F).
CAPACITY TEST
Refer to “Chart II”.
OK
NG
CAPACITY TEST
Refer to “Chart II”.
OK
NG
Ready for use
Replace
battery.
Ready
for use
Replace
battery.
* “STANDARD CHARGE” is recommended if the vehicle is in storage after charging.
왔
왔
왔
왔
왔
왔
왔
왔
왔
왔
왔
왔
왔
왔
왔
왔
왔
왔
왔
왔
왔
왔
왔
왔
BATTERY
EL-32
Chart II
CAPACITY TEST
Test using battery checker.
Test using load tester.
Follow manufacturer’s
instructions to check and
determine if battery is ser-
viceable.
OK
NG
Read load tester voltage
when specified discharging
current (Refer to Fig. 1.)
flows through battery for 15
seconds.
Ready for use
Go to next
step.
Above 9.6
volts
OK
Below 9.6
volts
NG
Ready for use
Go to next
step.
●
Check battery type and determine the specified current
using the following table.
Fig. 1 DISCHARGING CURRENT
(Load Tester)
Type (YUASA type code)
Current (A)
025
240
027
285
096
375
063
210
065
255
075
300
SEL008Z
왔
왔
왔
왔
왔
왔
왔
왔
왔
왔
BATTERY
Battery Test and Charging Chart (Cont’d)
EL-33
A: SLOW CHARGE
Determine initial charging current from specific gravity
referring to Fig. 2.
●
Charge battery.
●
Check charging voltage 30 minutes after starting the
battery charge.
12 to 15 volts
OK
Below 12 volts or above
15 volts
NG
Continue to charge for 12
hours.
Replace battery.
CHECKING SPECIFIC GRAVITY
Refer to “Specific Gravity Check”.
Conduct additional charge as per Fig. 3, if necessary.
Go to “CAPACITY TEST”.
Fig. 2 INITIAL CHARGING CURRENT SETTING (Slow charge)
CONVERTED
SPECIFIC
GRAVITY
BATTERY TYPE
(YUASA type code)
025
027
096
063
065
075
Below 1.100
7.0
(A)
7.0
(A)
8.5
(A)
8.0
(A)
10.0
(A)
10.0
(A)
●
Check battery type and determine the specified current using the
table shown above.
●
After starting charging, adjustment of charging current is not nec-
essary.
Fig. 3 ADDITIONAL CHARGE (Slow charge)
Below 1.150
1.150 - 1.200
1.200 - 1.240
Above 1.240
Charge for 5
hours at
initial charg-
ing current
setting.
Charge for 4
hours at
initial charg-
ing current
setting.
Charge for 2
hours at
initial charg-
ing current
setting.
Go to “CAPACITY TEST”.
왔
CAUTION:
●
Set charging current to value specified in Fig. 2. If
charger is not capable of producing specified current
value, set its charging current as close to that value as
possible.
●
Keep battery away from open flame while it is being
charged.
●
When connecting charger, connect leads first, then turn
on charger. Do not turn on charger first, as this may
cause a spark.
●
If battery temperature rises above 60°C (140°F), stop
charging. Always charge battery when its temperature is
below 60°C (140°F).
●
Remove cell caps during charging.
왔
왔
왔
왔
왔
왔
왔
왔
왔
왔
왔
왔
왔
왔
왔
BATTERY
Battery Test and Charging Chart (Cont’d)
EL-34
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.