Nissan Primera P11. Instruction — part 188
Wiring Diagram
NCEC0352
YEC072A
DTC P1402 EGR FUNCTION (OPEN) (IF SO EQUIPPED)
QG16
I
18DE
Wiring Diagram
EC-309
Diagnostic Procedure
NCEC0353
1
CHECK POWER SUPPLY
1. Disconnect EGR volume control valve harness connector.
2. Turn ignition switch “ON”.
3. Check voltage between terminals 2, 5 and ground with CONSULT-II or tester.
SEF556W
Voltage: Battery voltage
OK or NG
OK
©
GO TO 2.
NG
©
Check the following.
I
Harness or connectors E90, F73
I
Harness for open or short between EGR volume control valve and engine control
module relay
If NG, repair harness or connectors.
2
CHECK OUTPUT SIGNAL CIRCUIT
1. Turn ignition switch “OFF”.
2. Disconnect ECM harness connector.
3. Check harness continuity between
ECM terminal 8 and EGR volume control valve terminal 1,
ECM terminal 9 and EGR volume control valve terminal 4,
ECM terminal 17 and EGR volume control valve terminal 3,
ECM terminal 18 and EGR volume control valve terminal 6.
Refer to wiring diagram.
Continuity should exist.
If OK, check harness for short to ground and short to power.
OK or NG
OK
©
GO TO 3.
NG
©
Repair open circuit, short to ground or short to power in harness connectors.
3
CHECK EGR TEMPERATURE SENSOR
Refer to “Component Inspection”, EC-QG-304.
OK or NG
OK
©
GO TO 4.
NG
©
Replace EGR temperature sensor.
4
CHECK EGR VOLUME CONTROL VALVE
Refer to “Component Inspection”, EC-QG-251.
OK or NG
OK
©
GO TO 5.
NG
©
Replace EGR volume control valve.
DTC P1402 EGR FUNCTION (OPEN) (IF SO EQUIPPED)
QG16
I
18DE
Diagnostic Procedure
EC-310
5
CHECK INTERMITTENT INCIDENT
Perform “TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT”, EC-QG-102.
©
INSPECTION END
Component Inspection
NCEC0354
EGR TEMPERATURE SENSOR
NCEC0354S01
Check resistance change and resistance value.
<Reference data>
EGR temperature
°C (°F)
Voltage
V
Resistance
M
Ω
0 (32)
4.56
0.62 - 1.05
50 (122)
2.25
0.065 - 0.094
100 (212)
0.59
0.011 - 0.015
If NG, replace EGR temperature sensor.
SEF643Q
SEF068X
DTC P1402 EGR FUNCTION (OPEN) (IF SO EQUIPPED)
QG16
I
18DE
Diagnostic Procedure (Cont’d)
EC-311
EGR VOLUME CONTROL VALVE
NCEC0354S04
With CONSULT-II
1)
Disconnect EGR volume control valve harness connector.
2)
Check resistance between the following terminals.
terminal 2 and terminals 1, 3
terminal 5 and terminals 4, 6
Temperature °C (°F)
Resistance
Ω
20 (68)
20 - 24
3)
Reconnect EGR volume control valve harness connector.
4)
Remove EGR volume control valve from cylinder head.
(The EGR volume control valve harness connector should
remain connected.)
5)
Turn ignition switch “ON”.
6)
Perform “EGR VOL CONT/V” in “ACTIVE TEST” mode with
CONSULT-II. Check that EGR volume control valve shaft
moves smoothly forward and backward according to the valve
opening
If NG, replace the EGR volume control valve.
Without CONSULT-II
1)
Disconnect EGR volume control valve harness connector.
2)
Check resistance between the following terminals.
terminal 2 and terminals 1, 3
terminal 5 and terminals 4, 6
Temperature °C (°F)
Resistance
Ω
20 (68)
20 - 24
3)
Turn ignition switch “ON” and “OFF”. Check that EGR volume
control valve shaft moves smoothly forward and backward
according to the ignition switch position.
If NG, replace the EGR volume control valve.
SEF069X
SEF558W
NEF122A
SEF560W
DTC P1402 EGR FUNCTION (OPEN) (IF SO EQUIPPED)
QG16
I
18DE
Component Inspection (Cont’d)
EC-312