Nissan Frontier D22. Instruction — part 72
DTC P0710 A/T FLUID TEMPERATURE SENSOR CIRCUIT
AT-257
[RE4R01A]
D
E
F
G
H
I
J
K
L
M
A
B
AT
Wiring Diagram — AT — FTS
ECS007M9
WCWA0147E
AT-258
[RE4R01A]
DTC P0710 A/T FLUID TEMPERATURE SENSOR CIRCUIT
Diagnostic Procedure
ECS007MA
1.
CHECK A/T FLUID TEMPERATURE SENSOR WITH TERMINAL CORD ASSEMBLY
1.
Turn ignition switch to OFF position.
2.
Disconnect terminal cord assembly connector in engine compartment.
3.
Check resistance between terminal cord assembly connector E72 terminals 6 and 7 when A/T is cold
[20
°C (68°F)].
Is resistance approx. 2.5 k
Ω?
Yes
>> GO TO 2.
No
>> 1. Remove oil pan.
2. Check the following items:
–
A/T fluid temperature sensor
Refer to
AT-260, "A/T FLUID TEMPERATURE SENSOR"
.
–
Harness of terminal cord assembly for short or open
AAT483A
DTC P0710 A/T FLUID TEMPERATURE SENSOR CIRCUIT
AT-259
[RE4R01A]
D
E
F
G
H
I
J
K
L
M
A
B
AT
2.
CHECK INPUT SIGNAL OF A/T FLUID TEMPERATURE SENSOR
With CONSULT-II
1.
Start engine.
2.
Select “TCM INPUT SIGNALS” in “DATA MONITOR” mode for “A/T” with CONSULT-II.
3.
Read out the value of “FLUID TEMP SE”.
Without CONSULT-II
1.
Start engine.
2.
Check voltage between TCM harness connector M78 terminal 47 and ground while warming up A/T.
OK or NG
OK
>> GO TO 3.
NG
>> Check the following item:
●
Harness for short or open between TCM and terminal cord assembly (Main harness)
3.
CHECK DTC
Perform Diagnostic Trouble Code (DTC) confirmation procedure. Refer to
CODE (DTC) CONFIRMATION PROCEDURE"
OK or NG
OK
>> INSPECTION END.
NG
>> 1. Perform TCM input/output signal inspection.
2. If NG, recheck TCM pin terminals for damage or loose connection with harness connector.
Voltage
Cold [20
°C (68°F)] →
Hot [80
°C (176°F)]
: Approximately 1.5V
→
0.5V
SAT614J
Voltage
Cold [20
°C (68°F)] →
Hot [80
°C (176°F)]
: Approximately 1.5V
→
0.5V
AAT484A
AT-260
[RE4R01A]
DTC P0710 A/T FLUID TEMPERATURE SENSOR CIRCUIT
Component Inspection
ECS007MB
A/T FLUID TEMPERATURE SENSOR
●
For removal, refer to “
●
Check resistance between A/T fluid temperature sensor termi-
nals 6 and 7 while changing temperature as shown at left.
Temperature
°C (°F)
Resistance (Approx.)
20 (68)
2.5 k
Ω
80 (176)
0.3 k
Ω
AAT485A