Nissan Frontier D22. Instruction — part 401
DTC P0031, P0032, P0051, P0052 HO2S1 HEATER
EC-707
[VG33E]
C
D
E
F
G
H
I
J
K
L
M
A
EC
BANK 2
BBWA1078E
EC-708
[VG33E]
DTC P0031, P0032, P0051, P0052 HO2S1 HEATER
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than the ECM terminals, such as the ground.
Diagnostic Procedure
UBS00DFR
1.
CHECK HO2S1 POWER SUPPLY CIRCUIT
1.
Turn ignition switch OFF.
2.
Check heated oxygen sensor 1 harness protector.
3.
Disconnect corresponding heated oxygen sensor 1 harness
connector.
4.
Turn ignition switch ON.
5.
Check voltage between HO2S1 terminal 1 and ground with
CONSULT-II or tester.
OK or NG
OK
>> GO TO 3.
NG
>> GO TO 2.
TER-
MINAL
NO.
WIRE
COLOR
ITEM
CONDITION
DATA (DC Voltage)
121
BR
Heated oxygen sensor 1
heater (bank 2)
[Engine is running]
●
Engine speed is below 2,800 rpm
Approximately 0.4V
[Engine is running]
●
Engine speed is above 2,800 rpm
BATTERY VOLTAGE
(11 - 14V)
PBIB0636E
BBIA0188E
Voltage: Battery voltage
SEF633W
DTC P0031, P0032, P0051, P0052 HO2S1 HEATER
EC-709
[VG33E]
C
D
E
F
G
H
I
J
K
L
M
A
EC
2.
DETECT MALFUNCTIONING PART
Check the following.
●
Harness connectors M59, F27
●
Fuse block (J/B) connector M26
●
10A fuse
●
Harness for open or short between heated oxygen sensor 1 and fuse
>> Repair harness or connectors.
3.
CHECK HO2S1 HEATER OUTPUT CIRCUIT FOR OPEN AND SHORT
1.
Turn ignition switch OFF.
2.
Disconnect ECM harness connector.
3.
Check harness continuity between ECM terminal and HO2S1 terminal as follows.
Refer to Wiring Diagram.
4.
Also check harness for short to ground and short to power.
OK or NG
OK
>> GO TO 4.
NG
>> Repair open circuit or short to ground or short to power in harness or connectors.
4.
CHECK HEATED OXYGEN SENSOR 1 HEATER
Refer to
EC-709, "Component Inspection"
OK or NG
OK
>> GO TO 5.
NG
>> Replace malfunctioning heated oxygen sensor 1.
5.
CHECK INTERMITTENT INCIDENT
Refer to
EC-696, "TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT"
>> INSPECTION END
Component Inspection
UBS00DFS
HEATED OXYGEN SENSOR 1 HEATER
1.
Check resistance between HO2S1 terminals 3 and 1.
2.
Check continuity between HO2S1 terminals 2 and 1, 3 and 2.
3.
If NG, replace heated oxygen sensor 1.
CAUTION:
●
Discard any heated oxygen sensor which has been dropped
from a height of more than 0.5 m (19.7 in) onto a hard sur-
face such as a concrete floor; use a new one.
DTC
Terminals
Bank
ECM
Sensor
P0031
119
3
Bank 1
P0051
121
3
Bank 2
Continuity should exist.
Resistance: 2.3 - 4.3
Ω at 25°C (77°F)
Continuity should not exist.
AEC158A
EC-710
[VG33E]
DTC P0031, P0032, P0051, P0052 HO2S1 HEATER
●
Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread
Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.
Removal and Installation
UBS00DFT
HEATED OXYGEN SENSOR 1