Nissan Rogue. Instruction — part 1014
RF-36
< DTC/CIRCUIT DIAGNOSIS >
DOOR SWITCH
3. Check continuity between door switch harness connector and ground.
Is the inspection result normal?
YES
>> Replace BCM. Refer to
BCS-75, "Removal and Installation"
NO
>> Repair or replace harness.
3.
CHECK DOOR SWITCH
.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Replace malfunctioning door switch. Refer to
DLK-276, "Removal and Installation"
4.
CHECK INTERMITTENT INCIDENT
GI-44, "Intermittent Incident"
>> Inspection End.
Component Inspection
INFOID:0000000011382845
1.
CHECK DOOR SWITCH
1. Turn ignition switch OFF.
2. Disconnect malfunctioning door switch connector.
3. Check continuity between door switch terminals.
Is the inspection result normal?
YES
>> Inspection End.
NO
>> Replace malfunctioning door switch. Refer to
DLK-276, "Removal and Installation"
WITHOUT INTELLIGENT KEY
Description
INFOID:0000000011382856
Detects door open/close condition.
Component Function Check
INFOID:0000000011382857
1.
CHECK FUNCTION
Door switch
BCM
Continuity
Connector
Terminal
Connector
Terminal
Front LH
B71
3
B16
57
Yes
Front RH
B141
53
Rear LH
B70
52
Rear RH
B142
50
Door switch
Ground
Continuity
Connector
Terminal
Front LH
B71
3
No
Front RH
B141
Rear LH
B70
Rear RH
B142
Door switch
Condition
Continuity
Terminal
3
Ground contact is part of the
switch.
Door switch
Pressed
No
Released
Yes
DOOR SWITCH
RF-37
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
RF
N
O
P
1. Select “DOOR LOCK” of “BCM” using CONSULT.
2. Select “DOOR SW-DR”, “DOOR SW-AS”, “DOOR SW-RL”, “DOOR SW-RR”, in “Data Monitor”.
3. Check that the function operates normally according to the following conditions:
Is the inspection result normal?
YES
>> Door switch is OK.
NO
>> Refer to
Diagnosis Procedure
INFOID:0000000011382858
Regarding Wiring Diagram information, refer to
.
1.
CHECK DOOR SWITCH INPUT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect malfunctioning door switch connector.
3. Check signal between malfunctioning door switch harness connector and ground using oscilloscope.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK DOOR SWITCH CIRCUIT
1. Disconnect BCM connector.
2. Check continuity between door switch harness connector and BCM harness connector.
Monitor item
Condition
Status
DOOR SW-DR
Front door LH
Open
On
Closed
Off
DOOR SW-AS
Front door RH
Open
On
Closed
Off
DOOR SW-RL
Rear door LH
Open
On
Closed
Off
DOOR SW-RR
Rear door RH
Open
On
Closed
Off
(+)
(–)
Signal
(Reference value)
Door switch
Connector
Terminal
Front LH
B71
3
Ground
7.0 - 8.0 V
Front RH
B141
Rear LH
B70
Rear RH
B142
PKIB4960J
RF-38
< DTC/CIRCUIT DIAGNOSIS >
DOOR SWITCH
3. Check continuity between door switch harness connector and ground.
Is the inspection result normal?
YES
>> Replace BCM. Refer to
BCS-135, "Removal and Installation"
.
NO
>> Repair or replace harness.
3.
CHECK DOOR SWITCH
.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Replace malfunctioning door switch. Refer to
DLK-396, "Removal and Installation"
4.
CHECK INTERMITTENT INCIDENT
GI-44, "Intermittent Incident"
>> Inspection End.
Component Inspection
INFOID:0000000011382859
1.
CHECK DOOR SWITCH
1. Turn ignition switch OFF.
2. Disconnect door switch connector.
3. Check door switch.
Is the inspection result normal?
YES
>> Inspection End.
NO
>> Replace malfunctioning door switch. Refer to
DLK-396, "Removal and Installation"
Door switch
BCM
Continuity
Connector
Terminal
Connector
Terminal
Front LH
B71
3
B16
57
Yes
Front RH
B141
53
Rear LH
B70
52
Rear RH
B142
50
Door switch
Ground
Continuity
Connector
Terminal
Front LH
B71
3
No
Front RH
B141
Rear LH
B70
Rear RH
B142
Terminal
Door switch condition
Continuity
Door switch
3
Ground part of
door switch
Pressed
No
Released
Yes
MOONROOF DOES NOT OPERATE PROPERLY
RF-39
< SYMPTOM DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
RF
N
O
P
SYMPTOM DIAGNOSIS
MOONROOF DOES NOT OPERATE PROPERLY
Diagnosis Procedure
INFOID:0000000011280152
1.
CHECK BCM POWER SUPPLY AND GROUND CIRCUIT
Check BCM power supply and ground circuit.
Refer to
(with Intelligent Key System),
BCS-128, "Diagnosis Procedure"
(with-
out Intelligent Key System)
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace malfunctioning parts.
2.
CHECK MOONROOF MOTOR ASSEMBLY POWER SUPPLY AND GROUND CIRCUIT
Check moonroof motor assembly power supply and ground circuit.
Is the inspection result normal?
YES
>> Check intermittent incident. Refer to
GI-44, "Intermittent Incident"
.
NO
>> Repair or replace malfunctioning parts.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.