Nissan Rogue. Instruction — part 1215
VTL-6
< SYSTEM DESCRIPTION >
VENTILATION SYSTEM
SYSTEM DESCRIPTION
VENTILATION SYSTEM
System Description
INFOID:0000000011280000
OUTLINE
Automatic A/C
The ventilation system is controlled by the A/C switch assembly. For details of the automatic air conditioner
system, refer to
Instruction A/C
The ventilation system is controlled by the front air control. For details of the instruction air conditioner system,
AIR FLOW
Front
Rear
ALIIA0875ZZ
AWIIA1778ZZ
VENTILATION SYSTEM
VTL-7
< SYSTEM DESCRIPTION >
C
D
E
F
G
H
J
K
L
M
A
B
VTL
N
O
P
• *1: Air flow is also supplied to front foot until passenger room temperature stabilizes when temperature set-
ting is other than 18
°C (60°F). At that time, air flowing is the same as 18°C (60°F) setting.
• *2: During automatic defogging control.
Discharge air flow
Mode posi-
tion
Condition
Air outlet / distribution
DEF
(1)
VENT
FOOT
Side (2) Center (3)
Front (4)
Center (5)
Upper Vent:
ON
Temperature con-
trol switch
18
°C (60°F)
—
×
×
—
—
Other than 18
°C
(60
°F)
*1
—
×
×
—
—
—
—
×
×
×
×
—
—
—
—
×
×
—
×
—
—
×
×
—
×
—
—
—
—
*2
—
×
—
—
—
—
VTL-8
< REMOVAL AND INSTALLATION >
DUCTS AND GRILLES
REMOVAL AND INSTALLATION
DUCTS AND GRILLES
Exploded View
INFOID:0000000011280001
DEFROSTER NOZZLE
DEFROSTER NOZZLE : Removal and Installation
INFOID:0000000011280002
REMOVAL
1.
Side defroster duct (RH)
2.
Defroster nozzle
3.
Side defroster duct (LH)
4.
Center ventilator duct
5.
Heating and cooling unit assembly
6.
Front foot duct (LH)
7.
Front floor connecting duct (LH)
8.
Front floor duct (LH)
9.
Rear center ventilator duct
10. Adaptor duct
11. Front floor duct (RH)
12. Front floor connecting duct (RH)
13. Front foot duct (RH)
AWIIA1792ZZ
DUCTS AND GRILLES
VTL-9
< REMOVAL AND INSTALLATION >
C
D
E
F
G
H
J
K
L
M
A
B
VTL
N
O
P
1. Remove side defroster ducts (LH/RH). Refer to
VTL-9, "SIDE DEFROSTER DUCT : Removal and Instal-
.
2. Remove screws (A) and defroster nozzle (1).
INSTALLATION
Installation is in the reverse order of removal.
SIDE DEFROSTER DUCT
SIDE DEFROSTER DUCT : Removal and Installation
INFOID:0000000011280003
REMOVAL
1. Remove the instrument panel assembly. Refer to
IP-14, "INSTRUMENT PANEL ASSEMBLY : Removal
2. Remove the screws (A) and the side defroster duct (1).
NOTE:
LH side shown; RH similar.
INSTALLATION
Installation is in the reverse order of removal.
CENTER VENTILATOR DUCT
CENTER VENTILATOR DUCT : Removal and Installation
INFOID:0000000011280004
REMOVAL
1. Remove instrument panel assembly. Refer to
IP-14, "INSTRUMENT PANEL ASSEMBLY : Removal and
.
2. Remove screws (A) and center ventilator duct (1).
INSTALLATION
Installation is in the reverse order of removal.
ALIIA0953ZZ
ALIIA0954ZZ
ALIIA0955ZZ