Nissan Rogue. Instruction — part 617
B1231 DAYTIME RUNNING LIGHT RH POWER SUPPLY CIRCUIT
EXL-97
< DTC/CIRCUIT DIAGNOSIS >
[HALOGEN HEADLAMP]
C
D
E
F
G
H
I
J
K
M
A
B
EXL
N
O
P
B1231 DAYTIME RUNNING LIGHT RH POWER SUPPLY CIRCUIT
DTC Logic
INFOID:0000000011280748
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
CHECK SELF DIAGNOSTIC RESULT
With
CONSULT.
1. Turn ignition switch ON.
2. Perform “Self Diagnostic Result”.
Is DTC B1231 detected?
YES
>> Proceed to diagnosis procedure. Refer to
NO
>> Inspection End.
Diagnosis Procedure
INFOID:0000000011280749
1.
CHECK FRONT COMBINATION LAMP SHORT CIRCUIT TO GROUND
1. Disconnect front combination lamp connector and IPDM E/R connector.
2. Check continuity between IPDM E/R harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace harness.
2.
CHECK FRONT COMBINATION LAMP SHORT CIRCUIT TO GROUND
1. Reconnect IPDM E/R connector.
2. Check continuity between front combination lamp harness connector and ground.
Is the inspection result normal?
YES
>> Refer to
GI-44, "Intermittent Incident"
.
NO
>> Replace IPDM E/R. Refer to
PCS-40, "Removal and Installation"
.
DTC
Display Item
Malfunction detected condition
Possible causes
B1231
DTRL RH PWR SPLY CIRC
[CIRC SHORT TO GRND]
When a short circuit to ground in the daytime running
lamp circuit is detected.
• IPDM E/R
• Short to ground
IPDM E/R
Ground
Continuity
Connector
Terminal
E218
58
No
Front combination lamp
Ground
Continuity
Connector
Terminal
RH
E234
10
No
EXL-98
< DTC/CIRCUIT DIAGNOSIS >
[HALOGEN HEADLAMP]
B1256 FRONT FOG LAMP RH POWER SUPPLY CIRCUIT
B1256 FRONT FOG LAMP RH POWER SUPPLY CIRCUIT
DTC Logic
INFOID:0000000011280750
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
CHECK SELF DIAGNOSTIC RESULT
With
CONSULT.
1. Turn ignition switch ON.
2. Perform “Self Diagnostic Result”.
Is DTC B1256 detected?
YES
>> Proceed to diagnosis procedure. Refer to
NO
>> Inspection End.
Diagnosis Procedure
INFOID:0000000011280751
1.
CHECK FOG LAMP SHORT CIRCUIT TO GROUND
1. Disconnect fog lamp connector and IPDM E/R connector.
2. Check continuity between IPDM E/R harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace harness.
2.
CHECK FOG LAMP SHORT CIRCUIT TO GROUND
1. Reconnect IPDM E/R connector.
2. Check continuity between fog lamp harness connector and ground.
Is the inspection result normal?
YES
>> Refer to
GI-44, "Intermittent Incident"
.
NO
>> Replace IPDM E/R. Refer to
PCS-40, "Removal and Installation"
DTC
Display Item
Malfunction detected condition
Possible causes
B1256
FR FOG LAMP RH PWR SPLY CIRC
[CIRC SHORT TO GRND]
When a short circuit to ground is detected.
• IPDM E/R
• Short to ground
IPDM E/R
Ground
Continuity
Connector
Terminal
E218
57
No
Fog lamp
Ground
Continuity
Connector
Terminal
RH
E221
1
No
B20CB DAYTIME RUNNING LIGHT LH POWER SUPPLY CIRCUIT
EXL-99
< DTC/CIRCUIT DIAGNOSIS >
[HALOGEN HEADLAMP]
C
D
E
F
G
H
I
J
K
M
A
B
EXL
N
O
P
B20CB DAYTIME RUNNING LIGHT LH POWER SUPPLY CIRCUIT
DTC Logic
INFOID:0000000011280752
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
CHECK SELF DIAGNOSTIC RESULT
With
CONSULT.
1. Turn ignition switch ON.
2. Perform “Self Diagnostic Result”.
Is DTC B02CB detected?
YES
>> Proceed to diagnosis procedure. Refer to
NO
>> Inspection End.
Diagnosis Procedure
INFOID:0000000011280753
1.
CHECK FRONT COMBINATION LAMP SHORT CIRCUIT TO GROUND
1. Disconnect front combination lamp connector and IPDM E/R connector.
2. Check continuity between IPDM E/R harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace harness.
2.
CHECK FRONT COMBINATION LAMP SHORT CIRCUIT TO GROUND
1. Reconnect IPDM E/R connector.
2. Check continuity between fog lamp harness connector and ground.
Is the inspection result normal?
YES
>> Refer to
GI-44, "Intermittent Incident"
.
NO
>> Replace IPDM E/R. Refer to
PCS-40, "Removal and Installation"
.
DTC
Display Item
Malfunction detected condition
Possible causes
B02CB
DTRL LH PWR SPLY CIRC
[CIRC SHORT TO GRND]
When a short circuit to ground is detected.
• IPDM E/R
• Short to ground
IPDM E/R
Ground
Continuity
Connector
Terminal
E217
49
No
Front combination lamp
Ground
Continuity
Connector
Terminal
LH
E236
10
No
EXL-100
< DTC/CIRCUIT DIAGNOSIS >
[HALOGEN HEADLAMP]
B20CE HEADLAMP (HI) LH POWER SUPPLY CIRCUIT
B20CE HEADLAMP (HI) LH POWER SUPPLY CIRCUIT
DTC Logic
INFOID:0000000011280754
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
CHECK SELF DIAGNOSTIC RESULT
With
CONSULT.
1. Turn ignition switch ON.
2. Perform “Self Diagnostic Result”.
Is DTC B20CE detected?
YES
>> Proceed to diagnosis procedure. Refer to
EXL-100, "Diagnosis Procedure"
NO
>> Inspection End.
Diagnosis Procedure
INFOID:0000000011280755
1.
CHECK HEAD LAMP SHORT CIRCUIT TO GROUND
1. Disconnect front combination lamp connector and IPDM E/R connector.
2. Check continuity between IPDM E/R harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace harness.
2.
CHECK HEAD LAMP SHORT CIRCUIT TO GROUND
1. Reconnect IPDM E/R connector.
2. Check continuity between front combination lamp harness connector and ground.
Is the inspection result normal?
YES
>> Refer to
GI-44, "Intermittent Incident"
.
NO
>> Replace IPDM E/R. Refer to
PCS-40, "Removal and Installation"
DTC
Display Item
Malfunction detected condition
Possible causes
B20CE
DTRL LH PWR SPLY CIRC
[CIRC SHORT TO GRND]
Short to ground
• IPDM E/R
• Short to ground
IPDM E/R
Ground
Continuity
Connector
Terminal
E218
59
No
Front combination lamp
Ground
Continuity
Connector
Terminal
LH
E236
15
No
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.