Nissan Rogue. Instruction — part 986
PWC-26
< BASIC INSPECTION >
DIAGNOSIS AND REPAIR WORKFLOW
BASIC INSPECTION
DIAGNOSIS AND REPAIR WORKFLOW
Work Flow
INFOID:0000000011278683
OVERALL SEQUENCE
DETAILED FLOW
1.
INTERVIEW CUSTOMER
Interview the customer to obtain as much information as possible about the conditions and environment under
which the malfunction occurred.
ALKIA1982GB
DIAGNOSIS AND REPAIR WORKFLOW
PWC-27
< BASIC INSPECTION >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
>> GO TO 2.
2.
REPRODUCE THE MALFUNCTION
Reproduce the malfunction on the vehicle that the customer describes.
Inspect the relation of the symptoms and the condition when the symptoms occur.
>> GO TO 3.
3.
SYMPTOM DIAGNOSIS
Use Symptom diagnosis from the symptom inspection result in step 2 and then identify where to start perform-
ing the diagnosis based on possible causes and symptoms.
>> GO TO 4.
4.
COMPONENT DIAGNOSIS
Perform the diagnosis with Component diagnosis of the applicable system.
>> GO TO 5.
5.
REPAIR OR REPLACE THE MALFUNCTIONING PART
Repair or replace the specified malfunctioning parts.
>> GO TO 6.
6.
PERFORM FINAL OPERATIONAL CHECK
Check that malfunctions are not reproduced when obtaining the malfunction information from the customer,
referring to the symptom inspection result in step 2.
Are the malfunctions corrected?
YES
>> Inspection End.
NO
>> GO TO 3.
PWC-28
< BASIC INSPECTION >
INSPECTION AND ADJUSTMENT
INSPECTION AND ADJUSTMENT
ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL
ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : De-
scription
INFOID:0000000011278684
If any of the following work has been done Initial setting is necessary:
• Power supply to the main power window and door lock/unlock switch or power window motor is cut off by the
removal
of battery terminal or the battery fuse is blown.
• Disconnection and connection of main power window and door lock/unlock switch harness connector.
• Removal and installation of motor from regulator assembly.
• Operation of regulator assembly as an independent unit.
• Removal and installation of glass.
• Removal and installation of door glass run.
The following specified operations can not be performed under the non-initialized condition:
• Auto-up operation
• Anti-pinch function
ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Spe-
cial Repair Requirement
INFOID:0000000011278685
INITIALIZATION PROCEDURE
1. Disconnect battery minus terminal or main power and window door lock/unlock switch connector. Recon-
nect it after a minute or more.
2. Turn ignition switch ON.
3. Operate power window switch to fully open the window. (This operation is unnecessary if the window is
already fully open)
4. Continue pulling the power window switch UP (AUTO-UP operation). Even after glass stops at fully closed
position, keep pulling the switch for 2 seconds or more.
5. Initializing procedure is completely.
6. Inspect anti-pinch function.
CHECK ANTI-PINCH FUNCTION
1. Fully open the door window.
2. Place a piece of wood near fully closed position.
3. Close door glass completely with AUTO-UP.
• Check that glass lowers for approximately 150 mm (5.9 in) without pinching piece of wood and stops.
• Check that glass does not rise when operating the main power and door lock/unlock switch while lowering.
CAUTION:
• Perform initial setting when auto-up operation or anti-pinch function does not operate normally.
• Check that AUTO-UP operates before inspection when system initialization is performed.
• Do not check with hands and other body parts because they may be pinched. Do not get pinched.
• It may switch to fail-safe mode if open/close operation is performed continuously without full close.
Perform initial setting in that situation. Refer to
• Finish initial setting. Otherwise, next operation cannot be done.
1. Auto-up operation
2. Anti-pinch function
ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT
ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Description
INFOID:0000000011278686
Refer to
PWC-28, "ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Descrip-
.
ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Re-
INSPECTION AND ADJUSTMENT
PWC-29
< BASIC INSPECTION >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
quirement
INFOID:0000000011278687
PWC-28, "ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Special
for initialization procedure and check anti-pinch function.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.