Nissan Rogue. Instruction — part 513
EC-320
< DTC/CIRCUIT DIAGNOSIS >
[QR25DE]
P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R harness connector.
3. Check the continuity between EVAP canister purge volume control solenoid valve harness connector and
IPDM E/R harness connector.
4. Also check harness for short to ground.
Is the inspection result normal?
YES
>> Perform the trouble diagnosis for power supply circuit.
NO
>> Repair or replace error-detected parts.
3.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check the continuity between EVAP canister purge volume control solenoid valve harness connector and
ECM harness connector.
4. Also check harness for short to power.
Is the inspection result normal?
YES-1 >> With CONSULT: GO TO 4.
YES-2 >> Without CONSULT: GO TO 5.
NO
>> Repair or replace error-detected parts.
4.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
With CONSULT
1. Reconnect all harness connectors disconnected.
2. Start engine.
3. Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode of “ENGINE” using CONSULT.
4. Check that engine speed varies according to the valve opening.
Does engine speed vary according to the valve opening?
YES
>> GO TO 6.
NO
>> GO TO 5.
5.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
+
−
Voltage
EVAP canister purge volume
control solenoid valve
Connector
Terminal
F16
2
Ground
Battery voltage
+
−
Continuity
EVAP canister purge volume
control solenoid valve
IPDM E/R
Connector
Terminal
Connector
Terminal
F16
2
F35
73
Existed
+
−
Continuity
EVAP canister purge volume
control solenoid valve
ECM
Connector
Terminal
Connector
Terminal
F16
1
F51
17
Existed
P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE
EC-321
< DTC/CIRCUIT DIAGNOSIS >
[QR25DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
Check the EVAP canister purge volume control solenoid valve. Refer to
EC-318, "Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> Replace EVAP canister purge volume control solenoid valve. Refer to
.
6.
CHECK INTERMITTENT INCIDENT
GI-44, "Intermittent Incident"
.
>> INSPECTION END
Component Inspection
INFOID:0000000011278035
1.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT
1. Turn ignition switch OFF.
2. Reconnect all harness connectors disconnected.
3. Disconnect EVAP purge hoses connected to EVAP canister purge volume control solenoid valve.
4. Start engine.
5. Select “PURG VOL CONT/V” in “ACTIVE TEST” mode of “ENGINE” using CONSULT.
6. Touch “Qd” and “Qu” on CONSULT screen to adjust “PURG
VOL C/V” opening and check air passage continuity of EVAP
canister purge volume control solenoid valve as per the follow-
ing conditions.
Without CONSULT
1. Turn ignition switch OFF.
2. Disconnect EVAP canister purge volume control solenoid valve harness connector.
3. Disconnect EVAP purge hoses connected to EVAP canister purge volume control solenoid valve.
4. Check air passage continuity of EVAP canister purge volume
control solenoid valve as per the following conditions.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace EVAP canister purge volume control solenoid valve. Refer to
.
Condition
(PURG VOL C/V value)
Air passage continuity
between
and
100%
Existed
0%
Not existed
JMBIA0068ZZ
Condition
Air passage continuity
between
and
12 V direct current supply between
terminals 1 and 2
Existed
No supply
Not existed
JMBIA0068ZZ
EC-322
< DTC/CIRCUIT DIAGNOSIS >
[QR25DE]
P0447 EVAP CANISTER VENT CONTROL VALVE
P0447 EVAP CANISTER VENT CONTROL VALVE
DTC Description
INFOID:0000000011278036
DTC DETECTION LOGIC
POSSIBLE CAUSE
• Harness or connectors (EVAP canister vent control valve circuit is open or shorted.)
• EVAP canister vent control valve
FAIL-SAFE
Not applicable
DTC CONFIRMATION PROCEDURE
1.
PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure
before conducting the next test.
1. Turn ignition switch OFF and wait at least 10 seconds.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
Before performing the following procedure, confirm battery voltage is more than 11 V at idle.
>> GO TO 2.
2.
PERFORM DTC CONFIRMATION PROCEDURE
1. Start engine and wait at least 8 seconds.
2. Check 1st trip DTC.
Is 1st trip DTC detected?
YES
>> Proceed to
.
NO
>> INSPECTION END
Diagnosis Procedure
INFOID:0000000011278037
1.
INSPECTION START
Do you have CONSULT?
Do you have CONSULT?
YES
>> GO TO 2.
NO
>> GO TO 3.
2.
CHECK EVAP CANISTER VENT CONTROL VALVE CIRCUIT
With CONSULT
1. Turn ignition switch OFF and then turn ON.
2. Select “VENT CONTROL/V” in “ACTIVE TEST” mode of “ENGINE” using CONSULT.
3. Touch “ON/OFF” on CONSULT screen.
4. Check for operating sound of the valve.
Is the inspection result normal?
YES
>> GO TO 7.
NO
>> GO TO 3.
DTC No.
CONSULT screen terms
(Trouble diagnosis content)
DTC detecting condition
P0447
VENT CONTROL VALVE
(Evaporative emission system vent control
circuit open)
An improper voltage signal is sent to ECM through EVAP canister vent con-
trol valve.
Clicking sound should be heard.
P0447 EVAP CANISTER VENT CONTROL VALVE
EC-323
< DTC/CIRCUIT DIAGNOSIS >
[QR25DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
3.
CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY
1. Turn ignition switch OFF.
2. Disconnect EVAP canister vent control valve harness connector.
3. Turn ignition switch ON.
4. Check the voltage between EVAP canister vent control valve harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> GO TO 4.
4.
CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R harness connector.
3. Check the continuity between EVAP canister vent control valve harness connector and IPDM E/R harness
connector.
4. Also check harness for short to ground.
Is the inspection result normal?
YES
>> Perform the trouble diagnosis for power supply circuit.
NO
>> Repair or replace error-detected parts.
5.
CHECK EVAP CANISTER VENT CONTROL VALVE OUTPUT SIGNAL CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check the continuity between EVAP canister vent control valve harness connector and ECM harness con-
nector.
4. Also check harness for short to power.
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> Repair or replace error-detected parts.
6.
CHECK RUBBER TUBE FOR CLOGGING
1. Disconnect rubber tube connected to EVAP canister vent control valve.
2. Check the rubber tube for clogging.
Is the inspection result normal?
YES
>> GO TO 7.
NO
>> Clean the rubber tube using an air blower.
+
−
Voltage
EVAP canister vent control valve
Connector
Terminal
B108
1
Ground
Battery voltage
+
−
Continuity
EVAP canister vent control
valve
IPDM E/R
Connector
Terminal
Connector
Terminal
B108
1
F35
78
Existed
+
−
Continuity
EVAP canister vent control
valve
ECM
Connector
Terminal
Connector
Terminal
B108
2
E16
97
Existed