Nissan Titan A60. Instruction — part 793

PWC-76

< ECU DIAGNOSIS INFORMATION >

POWER WINDOW MAIN SWITCH

Reference Value (King Cab)

INFOID:0000000006161108

TERMINAL LAYOUT

PHYSICAL VALUES

MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH

10

(W/L)

Ground RAP signal

Input

IGN SW ON

Battery voltage

Within 45 second after ig-
nition switch is turned to
OFF.

Battery voltage

When front LH or RH door
is opened during retained
power operation.

0

11

(G/W)

8

Front door power window mo-
tor LH DOWN signal

Output

When front LH switch in
power window main switch
is operated DOWN.

Battery voltage

13

(G/Y)

2

Encoder pulse signal 1

Input

When power window mo-
tor operates.

14

(LG/W)

Ground Power window serial link

Input/

Output

IGN SW ON or power win-
dow timer operating.

15

(BR)

Ground Encoder power supply

Output

When ignition switch ON or
power window timer oper-
ates.

10

17

(B)

Ground Ground

0

19

(W/R)

Ground Battery power supply

Input

Battery voltage

Terminal No.

(Wire color)

Description

Condition

Voltage [V]

(Approx.)

+

Signal name

Input/

Output

JMKIA0070GB

JPMIA0013GB

LIIA2454E

POWER WINDOW MAIN SWITCH

PWC-77

< ECU DIAGNOSIS INFORMATION >

C

D

E

F

G

H

I

J

L

M

A

B

PWC

N

O

P

Terminal No.

(Wire color)

Description

Condition

Voltage [V]

(Approx.)

+

Signal name

Input/

Output

1

(W/R)

Ground

Battery power supply

Input

Battery voltage

5

(BR)

Ground

Encoder power supply

Output

When ignition switch ON or
power window timer operates

10

6

(L)

Ground

Door key cylinder switch
LH LOCK signal

Input

Key position
(Neutral

→ Locked)

5

→ 0

7

(R)

Ground

Door key cylinder switch
LH
UNLOCK signal

Input

Key position
(Neutral

→ Unlocked)

5

→ 0

8

(G/R)

11

Front door power window
motor LH UP signal

Output

When front LH switch in
power window main switch is
operated UP.

Battery voltage

9

(O)

3

Encoder pulse signal 2

Input

When power window motor op-
erates.

10

(W/L)

Ground

RAP signal

Input

IGN SW ON

Battery voltage

Within 45 second after ignition
switch is turned to OFF.

Battery voltage

When front LH or RH door is
opened during retained power
operation.

0

11

(G/W)

8

Front door power window
motor LH DOWN signal

Output

When front LH switch in
power window main switch is
operated DOWN.

Battery voltage

12

(LG/W)

Ground

Power window serial link

Input/

Output

IGN SW ON or power window
timer operating.

13

(G/Y)

3

Encoder pulse signal 1

Input

When power window motor op-
erates.

14

(W/B)

Ground

Encoder ground

0

15

(B)

Ground

Ground

0

JMKIA0070GB

JPMIA0013GB

JMKIA0070GB

PWC-78

< ECU DIAGNOSIS INFORMATION >

POWER WINDOW MAIN SWITCH

Fail Safe

INFOID:0000000006161111

FAIL-SAFE CONTROL

Switches to fail-safe control when malfunction is detected in encoder signal that detects up/down speed and

direction of door glass. Switches to fail-safe control when error beyond regulation value is detected between

the fully closed position and the actual position of the glass.

It changes to condition before initialization and the following functions do not operate when switched to fail-

safe control.

• Auto-up operation

• Anti-pinch function

• Retained power function

Perform initial operation to recover when switched to fail-safe mode. However, it switches back to fail-safe

control when malfunction is found in power window switch or in motor.

Error

Error condition

Pulse sensor malfunction

When only one side of pulse signal is being detected for more than the specified value.

Both pulse sensors mal-
function

When both pulse signals have not been detected for more than the specified value during glass open/
close operation.

Pulse direction malfunction

When the pulse signal that is detected during glass open/close operation detects the opposite condition
of power window motor operating direction.

Glass recognition position
malfunction 1

When it detects the error between glass fully closed position in power window switch memory and actual
fully closed position during glass open/close operation is more than the specified value.

Glass recognition position
malfunction 2

When it detects pulse count more than the value of glass full stroke during glass open/close operation.

Malfunction of not yet up-
dated closed position of
glass

When glass open/close operation is continuously performed without fully closing more than the specified
value (approximately 10 strokes).

FRONT POWER WINDOW SWITCH

PWC-79

< ECU DIAGNOSIS INFORMATION >

C

D

E

F

G

H

I

J

L

M

A

B

PWC

N

O

P

FRONT POWER WINDOW SWITCH

Reference Value

INFOID:0000000006161112

TERMINAL LAYOUT

PHYSICAL VALUES

POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH

LIIA2454E

Terminal No.

(Wire color)

Description

Condition

Voltage [V]

(Approx.)

+

Signal name

Input/

Output

3

(W/B)

Ground

Encoder ground

0

4

(G/R)

Ground

Encoder power supply

Output

When ignition switch ON or
power window timer operates

10

8

(L)

9

Power window motor
UP signal

Output

When power window motor is
UP at operated.

Battery voltage

9

(G)

8

Power window motor
DOWN signal

Output

When power window motor is
DOWN at operated.

Battery voltage

10

(W/R)

Ground

Battery power supply

Input

Battery voltage

11

(B)

Ground

Ground

0

12

(G/Y)

3

Encoder pulse signal 1

Input

When power window motor op-
erates.

JMKIA0070GB