Nissan Note E12. Instruction — part 682
WCS
WARNING CHIME SYSTEM
WCS-23
< WIRING DIAGRAM >
C
D
E
F
G
H
I
J
K
L
M
B
A
O
P
ABNIA4579GB
WCS-24
< BASIC INSPECTION >
DIAGNOSIS AND REPAIR WORK FLOW
BASIC INSPECTION
DIAGNOSIS AND REPAIR WORK FLOW
Work Flow
INFOID:0000000009014789
OVERALL SEQUENCE
DETAILED FLOW
1.
OBTAIN INFORMATION ABOUT SYMPTOM
Interview the customer to obtain as much information as possible about the conditions and environment under
which the malfunction occurred.
>> GO TO 2.
2.
CHECK SYMPTOM
• Check the symptom based on the information obtained from the customer.
• Check if any other malfunctions are present.
>> GO TO 3.
3.
CHECK CONSULT SELF-DIAGNOSIS RESULTS
1. Connect CONSULT and perform self-diagnosis. Refer to
.
JSNIA4485GB
WCS
DIAGNOSIS AND REPAIR WORK FLOW
WCS-25
< BASIC INSPECTION >
C
D
E
F
G
H
I
J
K
L
M
B
A
O
P
2. When DTC is detected, follow the instructions below:
-
Record DTC and Freeze Frame Data.
Are self-diagnosis results normal?
YES
>> GO TO 4.
NO
>> GO TO 5.
4.
NARROW DOWN MALFUNCTIONING PARTS BY SYMPTOM DIAGNOSIS
Perform symptom diagnosis and narrow down the malfunctioning parts.
>> GO TO 5.
5.
REPAIR OR REPLACE MALFUNCTIONING PARTS
Repair or replace malfunctioning parts.
NOTE:
If DTC is displayed, erase DTC after repairing or replacing malfunctioning parts.
>> GO TO 6.
6.
FINAL CHECK
Check that the warning buzzer in the combination meter operates normally.
Does it operate normally?
YES
>> Inspection End.
NO
>> GO TO 1.
WCS-26
< DTC/CIRCUIT DIAGNOSIS >
POWER SUPPLY AND GROUND CIRCUIT
DTC/CIRCUIT DIAGNOSIS
POWER SUPPLY AND GROUND CIRCUIT
COMBINATION METER
COMBINATION METER : Diagnosis Procedure
INFOID:0000000009549388
Regarding Wiring Diagram information, refer to
.
1.
CHECK FUSE
Check that the following fuses are not blown.
Is the fuse blown?
YES
>> GO TO 2.
NO
>> Replace the blown fuse after repairing the affected circuit.
2.
POWER SUPPLY CIRCUIT CHECK
1. Disconnect combination meter connector.
2. Check voltage between combination meter harness connector M24, terminals 27, 28, 15 and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace harness or connector.
3.
GROUND CIRCUIT CHECK
1. Turn ignition switch OFF.
2. Disconnect combination meter connector.
3. Check continuity between combination meter harness connector M24, terminals 21, 22, 23 and ground.
Is the inspection result normal?
YES
>> Inspection End.
Power source
Fuse No.
Battery
8
Ignition switch ON or START
3
Ignition switch ACC or ON
18
Terminals
Ignition switch position
(+)
(–)
OFF
ACC
ON
START
Connector
Terminal
M24
27
Ground
Battery voltage
Battery voltage
Battery
voltage
Battery voltage
28
0V
0V
Battery
voltage
Battery voltage
15
0V
Battery voltage
Battery
voltage
0V
Terminals
Continuity
(+)
(–)
Connector
Terminal
M24
21
Ground
Yes
22
23
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.