Nissan Xterra. Instruction — part 162
CHG
POWER GENERATION VOLTAGE VARIABLE CONTROL SYSTEM OPERATION
INSPECTION
CHG-11
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
POWER GENERATION VOLTAGE VARIABLE CONTROL SYSTEM OPER-
ATION INSPECTION
Diagnosis Procedure
INFOID:0000000009484982
Regarding Wiring Diagram information, refer to
CAUTION:
When performing this inspection, always use a charged battery that has completed the battery inspec-
tion. (When the charging rate of the battery is low, the response speed of the voltage change will
become slow. This can cause an incorrect inspection.)
1.
CHECK ECM (CONSULT)
Perform ECM self-diagnosis with CONSULT. Refer to
.
Self-diagnostic results content
No malfunction detected>> GO TO 2
Malfunction detected>> Check applicable parts, and repair or replace corresponding parts.
2.
CHECK OPERATION OF POWER GENERATION VOLTAGE VARIABLE CONTROL SYSTEM
1. Connect CONSULT and start the engine.
2. The selector lever is in “P” or “N” position and all of the electric loads and A/C, etc. are turned OFF.
3. Select “ALTERNATOR DUTY” in “Active Test” of “ENGINE”, and then check the value of “BATTERY
VOLT” monitor when DUTY value of “ALTERNATOR DUTY” is set to 40.0 %.
4. Check the value of “BATTERY VOLT” monitor when DUTY value of “ALTERNATOR DUTY” is set to
80.0%.
Is the measurement value within specification?
YES
>> Inspection End.
NO
>> GO TO 3
3.
CHECK IPDM E/R (CONSULT)
Perform IPDM E/R self-diagnosis with CONSULT. Refer to
.
Self-diagnostic results content
No malfunction detected>> GO TO 4
Malfunction detected>> Check applicable parts, and repair or replace corresponding parts.
4.
CHECK HARNESS BETWEEN GENERATOR AND IPDM E/R
“BATTERY VOLT”
2 seconds after setting the
DUTY value of “ALTERNA-
TOR DUTY” to 40.0 %
: 12 - 13.6 V
“BATTERY VOLT”
20 seconds after setting
the DUTY value of “ALTER-
NATOR DUTY” to 80.0 %
: +0.5 V or more against
the value of “BATTERY
VOLT” monitor when
DUTY value is 40.0 %
CHG-12
< DTC/CIRCUIT DIAGNOSIS >
POWER GENERATION VOLTAGE VARIABLE CONTROL SYSTEM OPERATION
INSPECTION
1. Turn ignition switch OFF.
2. Disconnect generator connector E205 and IPDM E/R connector
E122.
3. Check continuity between generator harness connector E205
(A) terminal 4 and IPDM E/R harness connector E122 (B) termi-
nal 37.
4. Check continuity between generator harness connector E205
(A) terminal 4 and ground.
Are the continuity test results as specified?
YES
>> Replace IPDM E/R. Refer to
PCS-27, "Removal and Installation"
NO
>> Repair harness or connector between IPDM E/R and generator.
A
B
Continuity
Connector
Terminal
Connector
Terminal
E205
4
E122
37
Yes
A
—
Continuity
Connector
Terminal
E205
4
Ground
No
ALMIA0196ZZ
CHG
B TERMINAL CIRCUIT
CHG-13
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
B TERMINAL CIRCUIT
Description
INFOID:0000000009484983
The terminal “1” (B) circuit supplies power to charge the battery and operate the vehicles electrical system.
Diagnosis Procedure
INFOID:0000000009484984
Regarding Wiring Diagram information, refer to
1.
CHECK TERMINAL “1” CONNECTION
1. Turn ignition switch OFF.
2. Verify terminal “1” is clean and tight.
Is the inspection result normal?
YES
>> GO TO 2
NO
>> Repair terminal “1” connection. Confirm repair by performing complete Charging system test
using EXP-800 NI or GR8-1200 NI (if available). Refer to applicable Instruction Instruction for proper
testing procedures.
2.
CHECK TERMINAL “1” CIRCUIT
Check voltage between generator connector E206 terminal 1 and
ground.
Is voltage reading as specified?
YES
>> GO TO 3.
NO
>> Check harness for open between generator and fusible
link.
3.
CHECK TERMINAL “1” CONNECTION (VOLTAGE DROP TEST)
1. Start engine, then engine running at idle and warm.
2. Check voltage between battery positive terminal and generator
connector E206 terminal 1.
Is the voltage reading as specified?
YES
>> Terminal “1” circuit is normal. Refer to
Flow (With EXP-800 NI or GR8-1200 NI)"
"Work Flow (Without EXP-800 NI or GR8-1200 NI)"
NO
>> Check harness between battery and generator for high resistance.
(+)
(-)
Voltage
Connector
Terminal
E206
1
Ground
Battery voltage
ALMIA0197ZZ
(+)
(-)
Voltage
Connector
Terminal
E206
1
Battery positive terminal
Less than 0.2V
ALMIA0198ZZ
CHG-14
< DTC/CIRCUIT DIAGNOSIS >
L TERMINAL CIRCUIT (OPEN)
L TERMINAL CIRCUIT (OPEN)
Description
INFOID:0000000009484985
The terminal “2” (L) circuit controls the charge warning lamp. The charge warning lamp illuminates when the
ignition switch is set to ON or START. When the generator is providing sufficient voltage with the engine run-
ning, the charge warning lamp will go off. If the charge warning lamp illuminates with the engine running, a
malfunction is indicated.
Diagnosis Procedure
INFOID:0000000009484986
Regarding Wiring Diagram information. Refer to
1.
CHECK “L” TERMINAL CONNECTION
1. Turn ignition switch OFF.
2. Check if “L” terminal is clean and tight.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair “L” terminal connection. Confirm repair by performing complete Charging system test
using EXP-800 NI or GR8-1200 NI (if available). Refer to applicable Instruction Instruction for proper
testing procedures.
2.
CHECK “L” TERMINAL CIRCUIT (OPEN)
1. Disconnect the generator connector.
2. Apply ground to generator harness connector terminal.
3. Check condition of the charge warning lamp with the ignition switch in the ON position.
Does it illuminate?
YES
>> “L” terminal circuit is normal. Refer to
CHG-2, "Work Flow (With EXP-800 NI or GR8-1200 NI)"
or
CHG-5, "Work Flow (Without EXP-800 NI or GR8-1200 NI)"
.
NO
>> GO TO 3.
3.
CHECK HARNESS CONTINUITY (OPEN CIRCUIT)
1. Disconnect the battery cable from the negative terminal.
2. Disconnect the combination meter connector.
3. Check continuity between generator harness connector and combination meter harness connector.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace the harness or connectors.
4.
CHECK HARNESS CONTINUITY (OPEN CIRCUIT)
Check continuity between combination meter harness connector and fuse block (J/B).
Generator
Ground
Condition
Connector
Terminal
Ignition switch position
Charge warning lamp
E205
2
ON
Illuminate
Generator
Combination meter
Continuity
Connector
Terminal
Connector
Terminal
E205
2
M24
2
Yes
Combination meter
Fuse box (J/B)
Continuity
Connector
Terminal Connector Terminal
M24
16
M4
5P
Yes
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст