Nissan Xterra. Instruction — part 199
DLK-38
< DTC/CIRCUIT DIAGNOSIS >
DOOR LOCK ACTUATOR
2.
CHECK DOOR LOCK ACTUATOR HARNESS
1. Disconnect BCM and front door lock actuator RH.
2. Check continuity between BCM connector (A) M20 terminals 65,
66 and front door lock actuator RH (B) D114 terminals 1, 2.
Is the inspection result normal?
YES
>> Replace front door lock actuator RH. Refer to
DLK-112, "Removal and Installation"
.
NO
>> Repair or replace harness.
3.
CHECK DOOR LOCK ACTUATOR HARNESS
1. Disconnect BCM and front door lock actuator RH.
2. Check continuity between BCM connector M20 terminals 65, 66
and ground.
Is the inspection result normal?
YES
>> Replace BCM. Refer to
BCS-50, "Removal and Installation"
NO
>> Repair or replace harness.
REAR LH
REAR LH : Description
INFOID:0000000009485043
Locks/unlocks the door with the signal from BCM.
REAR LH : Component Function Check
INFOID:0000000009485044
1.
CHECK FUNCTION
1. Use CONSULT to perform Active Test "DOOR LOCK".
2. Touch “ALL LCK” or “ALL ULK” to check that it works normally.
Is the inspection result normal?
YES
>> Door lock actuator is OK.
NO
>> Refer to
DLK-38, "REAR LH : Diagnosis Procedure"
.
REAR LH : Diagnosis Procedure
INFOID:0000000009485045
Regarding Wiring Diagram information, refer to
.
1.
CHECK DOOR LOCK ACTUATOR SIGNAL
Terminal
Continuity
65
2
Yes
66
1
ALKIA1192ZZ
Terminals
Continuity
65
Ground
No
66
ALKIA0631ZZ
DOOR LOCK ACTUATOR
DLK-39
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
1. Turn ignition switch OFF.
2. Check voltage between BCM connector M20 terminals 65, 66
and ground.
Is the inspection result normal?
YES
>> GO TO 2
NO
>> GO TO 3
2.
CHECK DOOR LOCK ACTUATOR HARNESS
1. Disconnect BCM and rear door lock actuator LH.
2. Check continuity between BCM connector (A) M20 terminals 65,
66 and rear door lock actuator LH connector (B) D205 terminals
1, 2.
Is the inspection result normal?
YES
>> Replace rear door lock actuator LH.
NO
>> Repair or replace harness.
3.
CHECK DOOR LOCK ACTUATOR HARNESS
1. Disconnect BCM and each door lock actuator.
2. Check continuity between BCM connector M20 terminals 65, 66
and ground.
Is the inspection result normal?
YES
>> Replace BCM. Refer to
BCS-50, "Removal and Installation"
NO
>> Repair or replace harness.
REAR RH
REAR RH : Description
INFOID:0000000009485046
Locks/unlocks the door with the signal from BCM.
Connector
Terminals
Condition
Voltage (V)
(Approx.)
(+)
(-)
M20
65
Ground
Door lock/unlock switch
is turned to LOCK
0
→ Battery voltage
for 300 ms
66
Door lock/unlock switch
is turned to UNLOCK
LIIA1048E
Terminals
Continuity
65
2
Yes
66
1
ALKIA1192ZZ
Terminals
Continuity
65
Ground
No
66
No
ALKIA0631ZZ
DLK-40
< DTC/CIRCUIT DIAGNOSIS >
DOOR LOCK ACTUATOR
REAR RH : Component Function Check
INFOID:0000000009485047
1.
CHECK FUNCTION
1. Use CONSULT to perform Active Test "DOOR LOCK".
2. Touch “ALL LCK” or “ALL ULK” to check that it works normally.
Is the inspection result normal?
YES
>> Door lock actuator is OK.
NO
>> Refer to
DLK-40, "REAR RH : Diagnosis Procedure"
.
REAR RH : Diagnosis Procedure
INFOID:0000000009485048
Regarding Wiring Diagram information, refer to
.
1.
CHECK DOOR LOCK ACTUATOR SIGNAL
1. Turn ignition switch OFF.
2. Check voltage between BCM connector M20 terminals 65, 66
and ground.
Is the inspection result normal?
YES
>> GO TO 2
NO
>> GO TO 3
2.
CHECK DOOR LOCK ACTUATOR HARNESS
1. Disconnect BCM and rear door lock actuator RH.
2. Check continuity between BCM connector (A) M20 terminals 65,
66 and rear door lock actuator RH connector (B) D305 terminals
1, 2.
Is the inspection result normal?
YES
>> Replace rear door lock actuator RH.
NO
>> Repair or replace harness.
3.
CHECK DOOR LOCK ACTUATOR HARNESS
1. Disconnect BCM and rear door lock actuator RH.
Connector
Terminals
Condition
Voltage (V)
(Approx.)
(+)
(-)
M20
65
Ground
Door lock/unlock switch
is turned to LOCK
0
→ Battery voltage
for 300 ms
66
Door lock/unlock switch
is turned to UNLOCK
LIIA1048E
Terminals
Continuity
65
2
Yes
66
1
ALKIA1192ZZ
DOOR LOCK ACTUATOR
DLK-41
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
2. Check continuity between BCM connector (A) M20 terminals 65,
66 and ground.
Is the inspection result normal?
YES
>> Replace BCM. Refer to
BCS-50, "Removal and Installation"
NO
>> Repair or replace harness.
BACK DOOR
BACK DOOR : Description
INFOID:0000000009485049
Locks/unlocks the door with the signal from BCM.
BACK DOOR : Component Function Check
INFOID:0000000009485050
1.
CHECK FUNCTION
1. Use CONSULT to perform Active Test DOOR LOCK.
2. Touch “ALL LCK” or “ALL ULK” to check that it works normally.
Is the inspection result normal?
YES
>> Door lock actuator is OK.
NO
>> Refer to
DLK-41, "BACK DOOR : Diagnosis Procedure"
BACK DOOR : Diagnosis Procedure
INFOID:0000000009485051
Regarding Wiring Diagram information, refer to
.
1.
CHECK DOOR LOCK ACTUATOR SIGNAL
1. Turn ignition switch OFF.
2. Check voltage between BCM connector M20 terminals 65, 66
and ground.
Is the inspection result normal?
YES
>> GO TO 2
NO
>> GO TO 3
2.
CHECK DOOR LOCK ACTUATOR HARNESS
1. Disconnect BCM and back door lock actuator.
Terminals
Continuity
65
Ground
No
66
ALKIA0631ZZ
Connector
Terminals
Condition
Voltage (V)
(Approx.)
(+)
(-)
M20
65
Ground
Door lock/unlock switch
is turned to LOCK
0
→ Battery voltage
for 300 ms
66
Door lock/unlock switch
is turned to UNLOCK
LIIA1048E