Nissan Maxima. Instruction — part 344
TRUNK OPENER REQUEST SWITCH
DLK-95
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
Is the inspection result normal?
YES
>> GO TO 3
NO
>> Repair or replace harness between BCM and trunk opener request switch.
3.
CHECK TRUNK OPENER REQUEST SWITCH GROUND CIRCUIT
Check continuity between trunk opener request switch connector and ground.
Is the inspection result normal?
YES
>> GO TO 4
NO
>> Repair or replace trunk opener request switch ground circuit.
4.
CHECK BCM OUTPUT SIGNAL
1. Connect BCM connector.
2. Check voltage between BCM connector and ground.
Is the inspection result normal?
YES
>> GO TO 5
NO
>> Replace BCM. Refer to
BCS-79, "Removal and Installation"
5.
CHECK TRUNK OPENER REQUEST SWITCH
DLK-95, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 6
NO
>> Replace trunk opener request switch.
6.
CHECK INTERMITTENT INCIDENT
GI-41, "Intermittent Incident"
.
>> Inspection End.
Component Inspection
INFOID:0000000009471680
1.
CHECK TRUNK OPENER REQUEST SWITCH
Check trunk opener request switch.
BCM connector
Terminal
Ground
Continuity
M21
141
No
Trunk opener request switch connector
Terminal
Ground
Continuity
T5
2
Yes
Terminals
Voltage (V)
(Approx.)
(+)
(–)
BCM connector
Terminal
M21
141
Ground
ALKIA0397ZZ
JPMIA0016GB
DLK-96
< DTC/CIRCUIT DIAGNOSIS >
TRUNK OPENER REQUEST SWITCH
Is the inspection result normal?
YES
>> Inspection End.
NO
>> Replace trunk opener request switch.
Terminal
Trunk opener request switch
condition
Continuity
Trunk opener request switch
1
2
Pressed
Yes
Released
No
DOOR LOCK ACTUATOR
DLK-97
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
DOOR LOCK ACTUATOR
DRIVER SIDE
DRIVER SIDE : Description
INFOID:0000000009471681
Locks/unlocks the door with the signal from BCM.
DRIVER SIDE : Component Function Check
INFOID:0000000009471682
1.
CHECK FUNCTION
1. Use CONSULT to perform Active Test (“DOOR LOCK”).
2. Touch “ALL LOCK” or “ALL UNLOCK” to check that it works normally.
Is the inspection result normal?
YES
>> Door lock actuator is OK.
NO
>> Refer to
DLK-97, "DRIVER SIDE : Diagnosis Procedure"
DRIVER SIDE : Diagnosis Procedure
INFOID:0000000009471683
Regarding Wiring Diagram information, refer to
.
1.
CHECK OUTPUT SIGNAL
Check voltage between BCM connector and ground.
Is the inspection result normal?
YES
>> GO TO 3
NO
>> GO TO 2
2.
CHECK DOOR LOCK ACTUATOR CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM and front door lock actuator driver side connector.
3. Check continuity between BCM connector and front door lock actuator driver side connector.
4. Check continuity between BCM connector and ground.
Is the inspection result normal?
YES
>> Replace front door lock actuator LH.
NO
>> Repair or replace harness.
Terminals
Condition of door lock and
unlock switch
Voltage (V)
(Approx.)
(+)
(–)
BCM
connector
Terminal
M17
8
Ground
Lock
0
→ Battery voltage → 0
9
Unlock
0
→ Battery voltage → 0
BCM connector
Terminal
Door lock actuator
connector
Terminal
Continuity
M17
8
D10
1
Yes
9
2
BCM connector
Terminal
Continuity
M17
8
Ground
No
9
DLK-98
< DTC/CIRCUIT DIAGNOSIS >
DOOR LOCK ACTUATOR
3.
CHECK INTERMITTENT INCIDENT
GI-41, "Intermittent Incident"
>> Inspection End.
PASSENGER SIDE
PASSENGER SIDE : Description
INFOID:0000000009471684
Locks/unlocks the door with the signal from BCM.
PASSENGER SIDE : Component Function Check
INFOID:0000000009471685
1.
CHECK FUNCTION
1. Use CONSULT to perform Active Test (“DOOR LOCK”).
2. Touch “ALL LOCK” or “ALL UNLOCK” to check that it works normally.
Is the inspection result normal?
YES
>> Door lock actuator is OK.
NO
>> Refer to
DLK-98, "PASSENGER SIDE : Diagnosis Procedure"
.
PASSENGER SIDE : Diagnosis Procedure
INFOID:0000000009471686
Regarding Wiring Diagram information, refer to
.
1.
CHECK DOOR LOCK ACTUATOR SIGNAL
Check voltage between BCM connector and ground.
Is the inspection result normal?
YES
>> GO TO 3
NO
>> GO TO 2
2.
CHECK DOOR LOCK ACTUATOR CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM and front door lock actuator RH connectors.
3. Check continuity between BCM connector and front door lock actuator RH.
4. Check continuity between BCM connector and ground.
Terminals
Condition of door lock
and unlock switch
Voltage (V)
(Approx.)
(+)
(–)
BCM
connector
Terminal
M17
8
Ground
Lock
0
→ Battery voltage → 0
5
Unlock
0
→ Battery voltage → 0
BCM connec-
tor
Terminal
Front door lock
actuator RH
connector
Terminal
Continuity
M17
8
D108
5
Yes
5
6
BCM connector
Terminal
Continuity
M17
8
Ground
No