Nissan Maxima. Instruction — part 1136
TM-8
< BASIC INSPECTION >
[CVT: RE0F09B]
ADDITIONAL SERVICE WHEN REPLACING TCM
ADDITIONAL SERVICE WHEN REPLACING TCM
Description
INFOID:0000000010113228
When replacing the TCM, perform the following work.
TCM PROGRAMMING
• Since vehicle specifications are not yet written in a new TCM, it is necessary to write them with CONSULT.
CAUTION:
When replacing TCM, save TCM data on CONSULT before removing TCM.
LOADING AND STORING OF CALIBRATION DATA
• The TCM acquires calibration data (individual characteristic value) of each solenoid that is stored in the
ROM assembly (in the control valve). This enables the TCM to perform accurate control. After the TCM is
replaced, check that the calibration data is correctly loaded and stored.
CAUTION:
When replacing TCM and transaxle assembly as a set, replace transaxle assembly first and then
replace TCM.
If the TCM is replaced in advance, perform “ADDITIONAL SERVICE WHEN REPLACING TRANSAXLE
ASSEMBLY”. Refer to
Procedure
INFOID:0000000010113229
CAUTION:
Immediately after TCM is replaced or after control valve or transaxle assembly is replaced (after TCM
initialization is complete), self-diagnosis result of “P1701”, “P1709” may be displayed. In this case,
erase self-diagnosis result using CONSULT. After erasing self-diagnosis result, perform DTC P1701
reproduction procedure and check that malfunction is not detected. Refer to
(P1701),
(P1709).
1.
CHECK TCM PART NUMBER
Check TCM part number to see whether it is blank TCM or not.
NOTE:
• Part number of blank TCM is 310F6-XXXXX.
• Check the part number when ordering TCM or with the one included in the label on the container box.
Is the TCM a blank TCM?
YES
>> GO TO 2.
NO
>> GO TO 3.
2.
SAVING TCM DATA
With CONSULT
1. Turn ignition switch OFF.
2. Turn ignition switch ON.
3. Select “Re/programming, Configuration”.
4. Select “AT/CVT”.
NOTE:
If “AT/CVT” is not displayed and TCM data cannot be saved on CONSULT, GO TO 3.
5. Select “Programming”.
6. Save TCM data on CONSULT according to the CONSULT display.
>> GO TO 3.
3.
REPLACE TCM
Replace TCM. Refer to
TM-168, "Removal and Installation"
>> GO TO 4.
4.
LOAD CALIBRATION DATA
1. Shift the selector lever to the “P” position.
2. Turn ignition switch ON.
ADDITIONAL SERVICE WHEN REPLACING TCM
TM-9
< BASIC INSPECTION >
[CVT: RE0F09B]
C
E
F
G
H
I
J
K
L
M
A
B
TM
N
O
P
3. Check that “P” is displayed on shift position indicator on combination meter.
NOTE:
Displayed approximately 1 – 2 seconds after the selector lever is moved to the “P” position.
Does the shift position indicator display “P”?
YES
>> GO TO 6.
NO
>> GO TO 5.
5.
DETECT MALFUNCTIONING ITEM
Check the following items:
• Harness between the TCM and the ROM assembly inside the transaxle assembly is open or shorted.
• Disconnected, loose, bent, collapsed, or otherwise abnormal connector housing terminals
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace the malfunctioning parts.
6.
STORE CALIBRATION DATA
1. Turn ignition switch OFF and wait for 5 seconds.
2. Turn ignition switch ON.
Does the shift position indicator display “P” at the same time when turning ON the ignition switch?
YES-1 (TCM is blank)>>GO TO 7.
YES-2 (TCM is not blank)>>WORK END
NO
>> Check harness between battery and TCM harness connector terminal. Refer to
7.
PROGRAMMING
With CONSULT
1. Select “Programming”.
2. Perform programming according to the CONSULT display.
>> WORK END
TM-10
< BASIC INSPECTION >
[CVT: RE0F09B]
ADDITIONAL SERVICE WHEN REPLACING TRANSAXLE ASSEMBLY
ADDITIONAL SERVICE WHEN REPLACING TRANSAXLE ASSEMBLY
Description
INFOID:0000000010113230
When replacing the transaxle assembly, perform the following work.
ERASING, LOADING AND STORING OF CALIBRATION DATA
• The TCM acquires calibration data (individual characteristic value) of each solenoid that is stored in the
ROM assembly (in the control valve). This enables the TCM to perform accurate control. For this reason,
after the transaxle assembly/control valve is replaced, it is necessary to erase the calibration data previously
stored in TCM, to load new calibration data, and to stored them.
ERASING OF CVT FLUID DEGRADATION LEVEL DATA
• TCM records the degradation level of the CVT fluid calculated from the vehicle driving status. Therefore, if
the transaxle assembly/control valve is replaced, it is necessary to erase the CVT fluid degradation level
data recorded by TCM.
Procedure
INFOID:0000000010113231
CAUTION:
Immediately after TCM is replaced or after transaxle assembly is replaced (after TCM initialization is
complete), self-diagnosis result of “P1701”, “P1709” may be displayed. In this case, erase self-diagno-
sis result using CONSULT. After erasing self-diagnosis result, perform DTC P1701 reproduction proce-
dure and check that malfunction is not detected. Refer to
(P1701),
1.
PREPARATION BEFORE WORK
With CONSULT
1. Start the engine.
CAUTION:
Never drive the vehicle.
2. Select “Data Monitor” in “TRANSMISSION”.
3. Select “ATFTEMP COUNT”.
Is “ATFTEMP COUNT” 47 [equivalent to 20
°C (68°F)] or more?
YES
>> GO TO 2.
NO
>> 1. Warm up the transaxle assembly until “ATFTEMP COUNT” reaches “47” [equivalent to 20
°C
(68
°F)] or more.
2. GO TO 2.
2.
PERFORM TCM INITIALIZATION
With CONSULT
1. Turn ignition switch OFF.
2. Turn ignition switch ON.
CAUTION:
Never start the engine.
3. Select “Self Diagnostic Results” in “TRANSMISSION”.
4. Shift selector lever to “R” position.
5. Depress slightly the accelerator pedal (Pedal angle: 2.0/8) while depressing the brake pedal.
6. Select “Erase” with step 5.
7. Release brake pedal and accelerator pedal.
8. Select “Special Function” in “TRANSMISSION”.
9. Select “CALIB DATA”.
10. Check that “CALIB DATA” value is as shown as in the following table.
Item name
Display value
UNIT CLB ID 1
00
UNIT CLB ID 2
00
UNIT CLB ID 3
00
UNIT CLB ID 4
00
ADDITIONAL SERVICE WHEN REPLACING TRANSAXLE ASSEMBLY
TM-11
< BASIC INSPECTION >
[CVT: RE0F09B]
C
E
F
G
H
I
J
K
L
M
A
B
TM
N
O
P
Is “CALIB DATA” value it?
YES
>> GO TO 3.
NO
>> GO TO 1.
3.
LOAD CALIBRATION DATA
1. Shift selector lever to “P” position.
2. Check that “P” is displayed on shift position indicator on combination meter.
NOTE:
It indicates approximately 1 – 2 seconds after shifting the selector lever to “P” position.
Does shift position indicator display “P”?
YES
>> GO TO 5.
NO
>> GO TO 4.
4.
DETECT MALFUNCTIONING ITEM
Check the following items:
• Harness between the TCM and the ROM assembly inside the transaxle assembly is open or shorted.
• Disconnected, loose, bent, collapsed, or otherwise abnormal connector housing terminals
• Power supply and ground of TCM. (Refer to
Is the inspection result normal?
YES
>> GO TO 1.
NO
>> Repair or replace the malfunctioning parts.
5.
STORE CALIBRATION DATA
1. Turn ignition switch OFF and wait for 5 seconds.
2. Turn ignition switch ON.
Does the shift position indicator display “P” at the same time when turning ON the ignition switch?
YES
>> GO TO 6.
NO
>> Check harness between battery and TCM harness connector terminal. Refer to
6.
ERASE CVT FLUID DEGRADATION LEVEL DATA
With CONSULT
1. Select “WORK SUPPORT” in “TRANSMISSION”.
2. Select “CONFORM CVTF DETERIORTN”.
3. Touch “Clear”.
>> WORK END