Nissan Juke F15. Instruction — part 711
EXL-64
< DTC/CIRCUIT DIAGNOSIS >
[XENON TYPE]
DAYTIME RUNNING LIGHT RELAY CIRCUIT
DAYTIME RUNNING LIGHT RELAY CIRCUIT
Component Function Check
INFOID:0000000012201650
1.
CHECK DAYTIME RUNNING LIGHT OPERATION
With CONSULT
1. Select “HEAD LAMP” of “BCM” using CONSULT.
2. Select “DAYTIME RUNNING LIGHT” in “Active Test” mode.
3. With operating the test items, check that the daytime running light is turned ON [Headlamp (HI) at approx-
imately half illumination].
Is the inspection result normal?
YES
>> Daytime running light relay circuit is normal.
NO
>> Refer to
.
Diagnosis Procedure
INFOID:0000000012201651
1.
CHECK DAYTIME RUNNING LIGHT RELAY FUSE
1. Turn ignition switch OFF.
2. Check that the following fuses are not blown (open).
Is the fuse blown (open)?
YES
>> Replace the blown fuse after repairing the affected circuit if a fuse is blown (open).
NO
>> GO TO 2.
2.
CHECK DAYTIME RUNNING LIGHT RELAY POWER SUPPLY
1. Remove daytime running light relay.
2. Check voltage between daytime running light relay harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace harness.
3.
CHECK DAYTIME RUNNING LIGHT RELAY
Check daytime running light relay. Refer to
EXL-65, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Replace daytime running light relay.
4.
CHECK DAYTIME RUNNING LIGHT RELAY CONTROL SIGNAL
With CONSULT
1. Install daytime running light relay.
2. Turn ignition switch ON.
3. Select “HEAD LAMP” of “BCM” using CONSULT.
4. Select “DAYTIME RUNNING LIGHT” in “Active Test” mode.
On
: Daytime running light ON [Headlamp (HI) at approximately half illumination]
Off
: Daytime running light OFF
Unit
Fuse No.
Capacity
Daytime running light relay
#24
10 A
+
-
Voltage
(Approx.)
Daytime running light relay
Connector
Terminal
E65
1
Ground
Battery voltage
5
DAYTIME RUNNING LIGHT RELAY CIRCUIT
EXL-65
< DTC/CIRCUIT DIAGNOSIS >
[XENON TYPE]
C
D
E
F
G
H
I
J
K
M
A
B
EXL
N
O
P
5. With operating the test item, check voltage between IPDM E/R harness connector and ground.
Is the inspection result normal?
YES
>> Daytime running light relay circuit is normal.
NO-1 >> Fixed at 0 – 1 V: GO TO 6.
NO-2 >> Fixed at 9 – 16 V: GO TO 5.
5.
CHECK DAYTIME RUNNING LIGHT REQUEST SIGNAL
With CONSULT
1. Select “DTRL REQ” in “Data Monitor” mode of “IPDM E/R” using CONSULT.
2. With operating the daytime running light ON condition, check the monitor status.
Is the inspection result normal?
YES
>> Replace IPDM E/R. Refer to
PCS-37, "Removal and Installation"
.
NO
>> Replace BCM. Refer to
BCS-94, "Removal and Installation"
6.
CHECK DAYTIME RUNNING LIGHT RELAY CONTROL SIGNAL CIRCUIT
1. Turn ignition switch OFF.
2. Remove daytime running light relay.
3. Disconnect IPDM E/R harness connector.
4. Check continuity between IPDM E/R harness connector and daytime running light relay harness connec-
tor.
Is the inspection result normal?
YES
>> Replace IPDM E/R. Refer to
PCS-37, "Removal and Installation"
.
NO
>> Repair or replace harness.
Component Inspection
INFOID:0000000012201652
1.
CHECK DAYTIME RUNNING LIGHT RELAY
1. Turn ignition switch OFF.
2. Remove daytime running light relay.
3. Apply battery voltage to daytime running light relay between terminals 1 and 2.
4. Check continuity of daytime running light relay terminals.
Is the inspection result normal?
YES
>> INSPECTION END
+
-
Test item
Voltage
IPDM E/R
Connector
Terminal
E13
28
Ground
DAYTIME RUNNING LIGHT
On
0 – 1 V
Off
9 – 16 V
Monitor item
Condition
Monitor status
DTRL REQ
Daytime running light
ON condition
On
OFF condition
Off
IPDM E/R
Daytime running light relay
Continuity
Connector
Terminal
Connector
Terminal
E13
28
E65
2
Existed
Daytime running light relay
Condition
Continuity
Terminal
5
3
Battery voltage
Apply
Existed
Not apply
Not existed
EXL-66
< DTC/CIRCUIT DIAGNOSIS >
[XENON TYPE]
DAYTIME RUNNING LIGHT RELAY CIRCUIT
NO
>> Replace daytime running light relay.
DAYTIME RUNNING LIGHT CIRCUIT
EXL-67
< DTC/CIRCUIT DIAGNOSIS >
[XENON TYPE]
C
D
E
F
G
H
I
J
K
M
A
B
EXL
N
O
P
DAYTIME RUNNING LIGHT CIRCUIT
Component Function Check
INFOID:0000000012201653
1.
CHECK DAYTIME RUNNING LIGHT OPERATION
With CONSULT
1. Select “EXTERNAL LAMPS” in “Active Test” mode of “IPDM E/R” using CONSULT.
2. With operating the test items, check that the daytime running light is turned ON.
Without CONSULT
1. Start IPDM E/R auto active test. Refer to
PCS-12, "Diagnosis Description"
2. Check that the daytime running light is turned ON.
Is the measurement normal?
YES
>> Daytime running light circuit is normal.
NO
>> Refer to
.
Diagnosis Procedure
INFOID:0000000012201654
1.
CHECK DAYTIME RUNNING LIGHT FUSE
1. Turn ignition switch OFF.
2. Check that the following fuse is not blown (open).
Is the fuse blown (open)?
YES
>> Replace the blown fuse after repairing the affected circuit if a fuse is blown (open).
NO
>> GO TO 2.
2.
CHECK DAYTIME RUNNING LIGHT POWER SUPPLY
With CONSULT
1. Turn ignition switch ON.
2. Select “EXTERNAL LAMPS” in “Active Test” mode of “IPDM E/R” using CONSULT.
3. With operating the test items, check the voltage between IPDM E/R harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Replace IPDM E/R. Refer to
PCS-37, "Removal and Installation"
.
3.
CHECK DAYTIME RUNNING LIGHT POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R connector and daytime running light connector.
3. Check continuity between IPDM E/R harness connector and daytime running light harness connector.
Fog
: Daytime running light ON
Off
: Daytime running light OFF
Unit
Location
Fuse No.
Capacity
Daytime running light
IPDM E/R
#50
15 A
+
-
Test item
Voltage
IPDM E/R
Connector
Terminal
RH
E12
19
Ground
EXTERNAL
LAMPS
Fog
9 – 16 V
Off
0 – 1 V
LH
20
Fog
9 – 16 V
Off
0 – 1 V
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.