Nissan Juke F15. Instruction — part 847
OPERATION
HAC-23
< SYSTEM DESCRIPTION >
[AUTOMATIC AIR CONDITIONING]
C
D
E
F
G
H
J
K
L
M
A
B
HAC
N
O
P
• In D-MODE: The following switches and dial cannot be operated.
- A/C switch
- OFF switch
- MODE switch
- Fan control dial
DEF switch
DEF mode turns ON
⇔ OFF each time when switch is pressed.
• When switch is pressed while air conditioning system is in the ON position.
- Air conditioning system operates according to the following setting when DEF mode is turned ON.
• Air outlet: DEF
• Air flow: Previous setting before turning DEF mode ON
• Air inlet: Fresh air intake
• A/C switch*: ON
- Air conditioning system operates according to the following setting when DEF mode is turned OFF.
• Air outlet: Previous setting before turning DEF mode ON
• Air flow: Previous setting before turning DEF mode OFF
• Air inlet: Fresh air intake
• A/C switch: Previous setting before turning DEF mode OFF
• When switch is pressed while air conditioning system is in the OFF position.
- Air conditioning system turns ON and operates according to the following setting when DEF mode
is turned ON.
• Air outlet: DEF
• Air flow: Automatic control
• Air inlet: Fresh air intake
• A/C switch*: ON
- Air conditioning system operates according to the following setting when DEF mode is turned OFF
• Air outlet: Automatic control
• Air flow: Previous setting before turning DEF mode OFF
• Air inlet: Fresh air intake
• A/C switch: Previous setting before turning DEF mode OFF
NOTE:
• When DEF mode is turned ON while “AUTO” is indicated on display, “AUTO” indication turns OFF.
However, air flow automatic control continues.
• *: A/C switch (compressor control) is turned ON when DEF switch is turned ON while A/C switch
indicator is OFF, but A/C switch indicator is not turned ON.
Intake switch
• Air inlet changes between recirculation (REC)
⇔ fresh air intake (FRE) each time this switch is
pressed.
-
switch indicator ON: Recirculation
*1, 2
-
switch indicator ON: Fresh air intake
• Switch indicator blinks 2 times and air inlet is set to automatic control when switch is pressed and
held for 2 seconds or more. (Switch indicator indicates air inlet status during automatic control.)
*1: A/C switch turns ON when recirculation (REC) is selected while air conditioning system is in the
ON position.
*2: A/C switch (compressor control) is turned ON when recirculation (REC) is selected while A/C
switch indicator is OFF, but A/C switch indicator is not turned ON.
NOTE:
• Air inlet can be changed when air conditioning system is in the OFF position.
• Air inlet cannot be changed to recirculation (REC) when air outlet is in the D/F or DEF position.
• Air inlet automatic control is released when A/C switch is in the OFF position.
Fan control dial
• Air flow can be instructionly set within a range of 1st – 7th speed using this dial.
- Clockwise rotation: Air flow increases
- Counterclockwise rotation: Air flow decreases
• Air conditioning system turns ON and operates according to the following setting when this dial is
turned one click to the left or right while air conditioning system is OFF.
- Air outlet: Automatic control
- Air flow: 1st speed
- Air inlet: Automatic control
- A/C switch: Previous setting before turning air conditioning system OFF
NOTE:
Air flow automatic control is released (“AUTO” turns OFF) when this dial is operated while “AUTO” is
indicated on display.
HAC-24
< SYSTEM DESCRIPTION >
[AUTOMATIC AIR CONDITIONING]
DIAGNOSIS SYSTEM (A/C AUTO AMP.)
DIAGNOSIS SYSTEM (A/C AUTO AMP.)
Description
INFOID:0000000012200019
Air conditioning system performs self-diagnosis, operation check, function diagnosis, and various settings
using diagnosis function of each control unit.
CONSULT Function
INFOID:0000000012200020
CONSULT performs the following functions via CAN communication with A/C auto amp.
NOTE:
Diagnosis should be performed with engine running. Door motor operation speeds become slower and NO
results may be returned even for normal operation if battery voltage drops below 12 V during self-diagnosis.
ECU IDENTIFICATION
Part number of A/C auto amp. can be checked.
SELF-DIAGNOSIS RESULTS
Diagnosis result that is judged by A/C auto amp. can be checked. Refer to
.
DATA MONITOR
Input/output signal of A/C auto amp. can be checked.
NOTE:
The following table includes information (items) inapplicable to this vehicle. For information (items) applicable
to this vehicle, refer to CONSULT display items.
ECU
Diagnostic item
(CONSULT)
A/C auto amp.
HVAC
Self Diagnostic Result
Data Monitor
Active Test
Work support
Multi display unit
MDU
Self Diagnostic Result
Data Monitor
Active Test
BCM
BCM-AIR CONDITIONER
Self Diagnostic Result
Data Monitor
ECM
ENGINE
Self Diagnostic Result
Data Monitor
IPDM E/R
IPDM E/R
Self Diagnostic Result
Data Monitor
Auto active test
Diagnostic mode
Description
Ecu Identification
Displays the part number of A/C auto amp.
Self Diagnostic Result
Displays the diagnosis results judged by A/C auto amp.
Data Monitor
Displays the input/output signal of A/C auto amp.
Active Test
The signals used to activate each device are forcibly supplied from A/C auto amp.
Work support
Changes the setting for each setting function and performs automatic adjustment of
components.
DIAGNOSIS SYSTEM (A/C AUTO AMP.)
HAC-25
< SYSTEM DESCRIPTION >
[AUTOMATIC AIR CONDITIONING]
C
D
E
F
G
H
J
K
L
M
A
B
HAC
N
O
P
Display item list
*: “DUTY” is displayed, but voltage is indicated. Or unit is not displayed but unit is (V).
ACTIVE TEST
The signals used to activate each device forcibly supplied from A/C auto amp. operation check of air condi-
tioning system can be performed.
Check each output device
*: Position of mode door motor is set to the status of automatic control that is selected by foot position setting
trimmer. Refer to
HAC-51, "Foot Position Setting Trimmer"
.
NOTE:
Perform the inspection of each output device after starting the engine because the compressor is operated.
WORK SUPPORT
Setting change of each setting functions and automatic adjustment of components can be performed.
Monitor item [Unit]
Description
AMB TEMP SEN
[
°C (°F)]
Ambient temperature value converted from ambient sensor signal received from ambi-
ent sensor
IN-VEH TEMP
[
°C (°F)]
In-vehicle temperature value converted from in-vehicle sensor signal received from in-
vehicle sensor
INT TEMP SEN
[
°C (°F)]
Evaporator fin temperature value converted from intake sensor signal received from in-
take sensor
SUNLOAD SEN
[w/m
2
] Sunload value converted from sunload sensor signal received from sunload sensor
AMB SEN CAL
[
°C (°F)] Ambient temperature value calculated by A/C auto amp.
IN-VEH CAL
[
°C (°F)] In-vehicle temperature value calculated by A/C auto amp.
INT TEMP CAL
[
°C (°F)] Evaporator fin temperature value calculated by A/C auto amp.
SUNL SEN CAL
[w/m
2
] Sunload value calculated by A/C auto amp.
COMP REQ SIG
[On/Off] Displays A/C ON signal ON/OFF status transmitted to BCM.
FAN REQ SIG
[On/Off] Displays blower fan ON signal ON/OFF status transmitted to BCM.
FAN DUTY
*
Target value of voltage (applied voltage) applied to blower motor by A/C auto amp.
XM
Target discharge air temperature judged by A/C auto amp. depending on the tempera-
ture setting and the value from each sensor
ENG COOL TEMP
[
°C (°F)] Engine coolant temperature signal value received from ECM via CAN communication
Test item
Description
HVAC TEST
The operation check of air conditioning system can be performed by selecting the mode.
Refer to the following table for the conditions of each mode.
Test item
MODE 1
MODE 2
MODE 3
MODE 4
MODE 5
MODE 6
MODE 7
Mode door motor position
VENT
VENT
B/L
B/L
FOOT
*
D/F
DEF
Intake door motor position
REC
REC
REC
20% FRE
80% FRE
FRE
FRE
Air mix door motor position
FULL COLD FULL COLD FULL COLD
MIDDLE
MIDDLE
FULL HOT
FULL HOT
Blower motor (Applied voltage)
5 V
8.5 V
10.5 V
8.5 V
8.5 V
8.5 V
13 V
Magnet clutch
ON
ON
ON
ON
OFF
OFF
ON
Blower motor (Blower fan ON
signal transmitted to BCM)
ON
ON
ON
ON
OFF
OFF
ON
HAC-26
< SYSTEM DESCRIPTION >
[AUTOMATIC AIR CONDITIONING]
DIAGNOSIS SYSTEM (A/C AUTO AMP.)
NOTE:
When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V
or less, the setting of WORK SUPPORT may be cancelled.
Work item
Description
Refer to
TEMP SET CORRECT
Setting change of temperature setting trimmer can be performed.
HAC-50, "Temperature
Setting Trimmer"
REC MEMORY SET
Setting change of inlet port memory function (REC) can be per-
formed.
HAC-50, "Inlet Port Mem-
ory Function (REC)"
FRE MEMORY SET
Setting change of inlet port memory function (FRE) can be per-
formed.
HAC-51, "Inlet Port Mem-
ory Function (FRE)"
BLOWER SET
Setting change of foot position setting trimmer can be performed.
HAC-51, "Foot Position
Setting Trimmer"
Door Motor Starting Position Reset
Starting position reset of air mix door motor and mode door motor can
be performed.