Lexus ES300 (1997 year). Service manual — part 121
BE05H–01
N19978
N19979
N19980
N19981
N19982
BE–90
–
BODY ELECTRICAL
COMBINATION METER
1474
1997 LEXUS ES300 (RM511U)
DISASSEMBLY
1.
REMOVE BACK COVER
(a)
Remove the 4 screws.
(b)
Remove the back cover from the meter case.
2.
REMOVE METER GLASS
(a)
Remove the 6 claws.
(b)
Remove the meter glass from the meter case.
3.
REMOVE METER PLATE
(a)
Remove the 3 claws.
(b)
Remove the meter plate from the meter case.
4.
REMOVE METER CIRCUIT PLATE
(a)
Remove the 27 bulbs.
(b)
Remove the 22 screws.
(c)
Remove the meter circuit plate from the meter case.
N19983
–
BODY ELECTRICAL
COMBINATION METER
BE–91
1475
1997 LEXUS ES300 (RM511U)
5.
REMOVE SPEEDOMETER ASSEMBLY
6.
REMOVE FUEL GAUGE
7.
REMOVE ENGINE COOLANT TEMPERATURE
GAUGE
BE05I–03
N20924
Connector ”A”
Connector ”B”
Connector ”C”
Connector ”D”
J–13–1–A
J–16–I
J–10–I
J–13–1
1
2
3
4
5
6
7
1
2
3
4
5
6
7
8
10 11 12 13
9
8
10 11 12 13
9
14 15 16
1
2
3
4
5 6
7 8
9 10
1
2
3
4
5
6
7
8
9 10 11 12 13
BE–92
–
BODY ELECTRICAL
COMBINATION METER
1476
1997 LEXUS ES300 (RM511U)
INSPECTION
1.
INSPECT COMBINATION METER WIRING CIRCUIT
Disconnect the connector ”A”, connector ”B”, connector ”C” and
connector ”D” from the combination meter and inspect the con-
nectors on the wire harness side.
Park/Neutral Position Switch:
Tester connection
Condition
Specified condition
B12 – Ground
Ignition switch ON and shift lever position ”P”
Battery positive voltage
B14 – Ground
Ignition switch ON and shift lever position ”R”
Battery positive voltage
C1 – Ground
Ignition switch ON and shift lever position ”N”
Battery positive voltage
C2 – Ground
Ignition switch ON and shift lever position ”D”
Battery positive voltage
B10 – Ground
Ignition switch ON and shift lever position ”2”
Battery positive voltage
B9 – Ground
Ignition switch ON and shift lever position ”L”
Battery positive voltage
Turn Signal Switch and Hazard Warning Switch:
Tester connection
Condition
Specified condition
B13 – Ground
Hazard warning switch ON
Battery positive voltage
↔
0V
B13 – Ground
Ignition switch ON and turn signal switch to
”Right”
Battery positive voltage
↔
0V
B11 – Ground
Hazard warning switch ON
Battery positive voltage
↔
0V
B11 – Ground
Ignition switch ON and turn signal switch to
”Left”
Battery positive voltage
↔
0V
Headlight:
Tester connection
Condition
Specified condition
C3 – C5
Light control switch ”HEAD”
(Dimmer switch ”LO”)
No voltage
C3 – C5
Light control switch ”HEAD”
(Dimmer switch ”HI” or ”Flash”)
Battery positive voltage
GAUGE Fuse:
Tester connection
Condition
Specified condition
D3 – Ground
Ignition switch position ACC, START
No voltage
D3 – Ground
Ignition switch position ON
Battery positive voltage
–
BODY ELECTRICAL
COMBINATION METER
BE–93
1477
1997 LEXUS ES300 (RM511U)
IGN Fuse:
Tester connection
Condition
Specified condition
B2 – Ground
*
2
Ignition switch position LOCK, ACC,
START
No voltage
B2 – Ground
*
2
Ignition switch position ON
Battery positive voltage
Fuel Sender Gauge:
Tester connection
Condition
Specified condition
D12 – D13
Float position Full, Approx. 91.1 mm
(3.587 in.)
Approx. 4.6V
D12 – D13
Float position 1/2, Approx. 34.2 mm
(1.346 in.)
Approx. 2.4V
D12 – D13
Float position Empty, Approx. 30.8 mm
(1.213 in.)
Approx. 0.3V
D11 – D12
Ignition switch ON
Approx. 5V
Ground (Signal):
Tester connection
Condition
Specified condition
D13 – Ground
Constant
Continuity
Ground (Engine):
Tester connection
Condition
Specified condition
A1 – Ground
Constant
Continuity
Ground (Power):
Tester connection
Condition
Specified condition
B15 – Ground
Constant
Continuity
Generator ”L” Terminal:
Tester connection
Condition
Specified condition
A10 – Ground
Engine stop
Continuity
A10 – Ground
Engine running
Battery positive voltage
Engine Oil Level Warning Switch:
Tester connection
Condition
Specified condition
C7 – Ground
Oil temperature above approx. 55
°
C
(131
°
F) and switch position OFF (float down)
No continuity
C7 – Ground
Oil temperature below approx. 55
°
C
(131
°
F)
Continuity
C7 – Ground
Oil temperature above approx. 55
°
C
(131
°
F) and switch position ON (float up)
Continuity
DOME fuse:
Tester connection
Condition
Specified condition
C8 – Ground
Constant
Battery positive voltage
Rheostat Light Control:
Tester connection
Condition
Specified condition
D1 – Ground
Light control switch TAIL or HEAD and
turn rheostat volume knob.
Voltage changes no voltage or voltage
fluctuates
*
2
Shift lever position is ”N” or ”P” position.
If circuit is not as specified, refer to BE–60 wiring diagram and inspect the circuit connected to other parts.