Lexus SC300 / Lexus SC400. Service manual — part 947
Lexus Supports ASE Certification
Page 1 of 12
Title:
SENSOR INSPECTION FOR AIR
CONDITIONING SYSTEM
Models:
’90 – Current All Models
Technical Service
Information Bulletin
December 16, 2004
A
C
005-04
This service bulletin contains inspection procedures to more precisely confirm proper
operation of the following temperature sensors of the air conditioning system. Follow the
procedures in this service bulletin when inspecting these sensors. These contents will be
reflected in future repair manuals.
S
Room Temperature Sensor
S
Ambient Temperature Sensor
S
Air Duct Sensor
S
Evaporator Temperature Sensor
S
Solar Sensor
S
Room Humidity Sensor
S
All 1990 – Current model year Lexus vehicles.
OP CODE
DESCRIPTION
TIME
OFP
T1
T2
N/A
Not Applicable to Warranty
–
–
–
–
HEA
TING & AIR CONDITIONING
Introduction
Applicable
Vehicles
Warranty
Information
SENSOR INSPECTION FOR AIR CONDITIONING SYSTEM – AC005-04
December 16, 2004
Page 2 of 12
1. Inspect Room Temperature Sensor.
A. Measure the sensor resistance.
Resistance Value at 77
°
F
(25
°
C)
1700 +/– 85
Ω
NOTE:
S
Even slightly touching the sensor
may change the resistance value.
Be sure to hold the connector of
the sensor.
S
When measuring, the sensor
temperature must be the same as
the ambient temperature.
HINT:
As the temperature increases, the
resistance decreases.
TEMPERATURE
°
F (
°
C)
SPECIFICATION k
Ω
50 (10)
3.00 to 3.73
59 (15)
2.45 to 2.88
68 (20)
1.95 to 2.30
77 (25)
1.60 to 1.80
86 (30)
1.28 to 1.47
95 (35)
1.00 to 1.22
104 (40)
0.80 to 1.00
113 (45)
0.65 to 0.85
122 (50)
0.50 to 0.70
131 (55)
0.44 to 0.60
140 (60)
0.36 to 0.50
Inspection
Procedure
Resistance
k
Ω
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
32
(0)
68
(20)
104
(40)
140
(60)
Temperature
°
F (
°
C)
Max
Min
SENSOR INSPECTION FOR AIR CONDITIONING SYSTEM – AC005-04
December 16, 2004
Page 3 of 12
2. Inspect Ambient
Temperature Sensor.
A. Measure the sensor resistance
according to the selected graph
(specification).
Resistance Value at 77
°
F
(25
°
C)
1700 +/– 85
Ω
NOTE:
S
Even slightly touching the sensor
may change the resistance value.
Be sure to hold the connector of
the sensor.
S
When measuring, the sensor
temperature must be the same as
the ambient temperature.
HINT:
As the temperature increases, the
resistance decreases.
TEMPERATURE
°
F (
°
C)
SPECIFICATION k
Ω
50 (10)
3.00 to 3.73
59 (15)
2.45 to 2.88
68 (20)
1.95 to 2.30
77 (25)
1.60 to 1.80
86 (30)
1.28 to 1.47
95 (35)
1.00 to 1.22
104 (40)
0.80 to 1.00
113 (45)
0.65 to 0.85
122 (50)
0.50 to 0.70
131 (55)
0.44 to 0.60
140 (60)
0.36 to 0.50
Inspection
Procedure
(Continued)
Resistance
k
Ω
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
32
(0)
68
(20)
104
(40)
140
(60)
Temperature
°
F (
°
C)
Max
Min
SENSOR INSPECTION FOR AIR CONDITIONING SYSTEM – AC005-04
December 16, 2004
Page 4 of 12
3. Inspect Air Duct Sensor.
A. Measure the sensor resistance
according to the table and
graph (specification).
NOTE:
S
Even slightly touching the sensor
may change the resistance value.
Be sure to hold the connector of
the sensor.
S
When measuring, the sensor
temperature must be the same as
the ambient temperature.
HINT:
As the temperature increases, the
resistance decreases.
TEMPERATURE
°
F (
°
C)
SPECIFICATION k
Ω
50 (10)
9.48 to 10.49
59 (15)
7.50 to 8.28
68 (20)
5.95 to 6.57
77 (25)
4.77 to 5.25
86 (30)
3.85 to 4.21
95 (35)
3.12 to 3.40
104 (40)
2.53 to 2.79
113 (45)
2.06 to 2.30
122 (50)
1.69 to 1.91
131 (55)
1.39 to 1.59
140 (60)
1.15 to 1.33
Inspection
Procedure
(Continued)
Resistance
k
Ω
15.0
10.0
5.0
0.0
32
(0)
68
(20)
104
(40)
140
(60)
Temperature
°
F (
°
C)
Max
Min
176
(80)
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.