Lexus SC300 / Lexus SC400. Service manual — part 14
Air Inlet Control System
(When the AUTO Switch is ON)
(a) The desired temperature is set using the TEMP switch.
(b) From the input signals (room temperature sensor, ambient temperature sensor and solar sensor) and the
temperature setting, the air conditioner control ECU determines the air inlet and outputs signals to the air
inlet servomotor assembly.
(c) When it receives signals from the ECU, the air inlet servomotor opens or closes the damper to change the
air inlet. When the air inlet is changed to the desired setting, it is detected by the air inlet damper position
sensor and the ECU stops the servomotor.
HINT: If the Mode switch is set on DEF, the ECU forcedly changes the air inlet to FRS.
(When the AUTO Switch is OFF)
The ECU fixes the air inlet according to the position of the manual switch.
AC–12
–
AIR CONDITIONING SYSTEM
Description
Part No.
Part Name
Note
07110-58011
(07117-58010)
(07117-78011)
(07117-88013)
(07117-88022)
(07117-88040)
07110-58040
07112-66040
07112-76060
07114-82020
07117-48050
Air Conditioner
Service Tool Set
(Refrigerant Drum
Service Valve)
(Refrigerant
Charging Gauge)
(Refrigerant
Charging Hose)
(Refrigerant
Charging Hose)
(Refrigerant
Charging Hose)
(Stop Valve)
Charging Hose Kit.
w/Stop Valve
Magnetic Clutch
Stopper
Magnetic Clutch
Remover
Snap Ring Pliers
Vacuum Pump Assy
Orange Color
If you require a stop valve, please order this kit.
Rated voltage AC220V
Illustration
Illustration
Part No.
Part Name
Note
09082-00015
TOYOTA
Electrical Tester
Measure voltage currant and resistance
Blue Color
Green Color
PREPARATION
SST (SPECIAL SERVICE TOOLS)
–
AIR CONDITIONING SYSTEM
Preparation
AC–13
EQUIPMENT
ÑÑÑÑÑÑÑÑÑÑÑÑÑÑ
ÑÑÑÑÑÑÑÑÑÑÑÑÑÑ
Part Name
ÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑ
ÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑ
Note
ÑÑÑÑÑÑÑÑÑÑÑÑÑÑ
ÑÑÑÑÑÑÑÑÑÑÑÑÑÑ
ÑÑÑÑÑÑÑÑÑÑÑÑÑÑ
Voltmeter
ÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑ
ÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑ
ÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑ
Measures voltage
ÑÑÑÑÑÑÑÑÑÑÑÑÑÑ
ÑÑÑÑÑÑÑÑÑÑÑÑÑÑ
ÑÑÑÑÑÑÑÑÑÑÑÑÑÑ
Ammeter
ÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑ
ÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑ
ÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑ
Measures current
ÑÑÑÑÑÑÑÑÑÑÑÑÑÑ
ÑÑÑÑÑÑÑÑÑÑÑÑÑÑ
Ohmmeter
ÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑ
ÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑ
Measures resistance
LUBRICANT
Item
Capacity
Classification
Item
cc
fl. oz
Classification
Compressor oil
When replacing receiver
When replacing condenser
When replacing evaporator
20
40–50
40–50
0.7
1.4–1.7
1.4–1.7
ND OIL 6,
SUNISO No. 5GS or equivalent
AC–14
–
AIR CONDITIONING SYSTEM
Preparation Cooling System
USE OF MANIFOLD GAUGE SET
INSTALLATION OF MANIFOLD GAUGE
SET
HINT: To prevent releasing refrigerant, use charging hoses
with a stop valve when installing the manifold gauge set to
service valves on the refrigerant line.
1.
CONNECT CHARGING HOSES WITH A STOP VALVE TO
MANIFOLD GAUGE SET
Tighten the nuts by hand.
CAUTION:
•
Do not connect the wrong hoses to the high
pressure and the low pressure sides.
•
To prevent loosening the nuts, do not apply
compressor oil to seat of the connection.
2.
CLOSE HAND VALVES OF BOTH STOP VALVES
3. CLOSE BOTH HAND VALVES OF MANIFOLD GAUGE
SET
4. REMOVE CAPS FROM SERVICE VALVES ON
REFRIGERANT LINE
5. CONNECT
STOP
VALVES
TO
SERVICE
VALVES
Tighten the nuts by hand.
CAUTION:
•
Do not connect the wrong hoses to the high
pressure and the low pressure sides.
•
To prevent loosening the nuts, do not apply
compressor oil to seat of the connection.
6.
OPEN HAND VALVES OF BOTH STOP VALVES
REMOVAL OF MANIFOLD GAUGE SET
1. CLOSE BOTH HAND VALVES OF MANIFOLD GAUGE
SET
2.
CLOSE HAND VALVES OF BOTH STOP VALVES
3.
DISCONNECT STOP VALVES FROM SERVICE VALVES
ON REFRIGERANT LINE
4.
INSTALL CAPS TO SERVICE VALVES ON REFRIGERANT
LINE
–
AIR CONDITIONING SYSTEM
Use of Manifold Gauge Set
AC–15