Lexus GS300/400 (2000 year). Service manual — part 19
I03739
I03737
I03738
I03740
–
AIR CONDITIONING
SENSOR
AC–73
2758
3.
REMOVE AMBIENT TEMPERATURE SENSOR
(a)
Disconnect the connector.
(b)
Using a clip remover, pull out the sensor from bumper re-
inforcement.
4.
REMOVE EVAPORATOR TEMPERATURE SENSOR
(a)
Remove these parts:
(1)
No.1 under cover
(2)
No.1 safety pad
(See page
)
(b)
Remove the evaporator temperature sensor.
(1)
Using a screwdriver, pull out the sensor with bracket
plate.
HINT:
Tape the screwdriver tip before use.
(2)
Release the 2 claws and remove the sensor from
bracket plate.
5.
REMOVE SMOG VENTILATION SENSOR
(a)
Disconnect the connector.
(b)
Remove the bolt and sensor.
AC0XL–01
AC–74
–
AIR CONDITIONING
SENSOR
2759
INSPECTION
1.
INSPECT SOLAR SENSOR CIRCUIT
Driver Side: (See page
Passnger Side: (See page
2.
INSPECT ROOM TEMPERATURE SENSOR CIRCUIT
(See page
3.
INSPECT AMBIENT TEMPERATURE SENSOR CIRCUIT
(See page
4.
INSPECT EVAPORATOR TEMPERATURE SENSOR
(See page
5.
INSPECT SMOG VENTILATION SENSOR CIRCUIT
(See page
AC0XM–01
–
AIR CONDITIONING
SENSOR
AC–75
2760
INSTALLATION
Installation is in the reverse order of removal (See page
I03741
2
1
3
4
AC0XN–01
Z13470
Magnetic Clutch Control
Low Pressure Side
ON (Continuity)
181 kpa
(1.85 kgf·cm
2
, 28 psi)
OFF (No Continuity)
High Pressure Side
3,140 kpa
(32.0 kgf·cm
2
, 455 psi)
OFF (No Continuity)
Z13471
Cooling Fan Control
ON
1,520 kpa
(15.5 kgf·cm
2
, 220 psi)
(No Continuity)
(Continuity)
OFF
1,230 kpa
(12.5 kgf·cm
2
, 178 psi)
AC–76
–
AIR CONDITIONING
PRESSURE SWITCH
2761
PRESSURE SWITCH
ON–VEHICLE INSPECTION
1.
SET ON MANIFOLD GAUGE SET
(See page
2.
DISCONNECT CONNECTOR FROM PRESSURE
SWITCH
3.
RUN ENGINE AT APPROX. 1,500 RPM
4.
Magnetic Clutch Control:
INSPECT PRESSURE SWITCH OPERATION
(a)
Connect the positive (+) lead from the ohmmeter to termi-
nal 4 and the negative (–) lead to terminal 1.
(b)
Check continuity between terminals when refrigerant
pressure is changed, as shown in the illustration.
If operation is not as specified, replace the pressure switch.
5.
Cooling Fan Control:
INSPECT PRESSURE SWITCH OPERATION
(a)
Connect the positive (+) lead from the ohmmeter to termi-
nal 2 and the negative (–) lead to terminal 3.
(b)
Check continuity between terminals when refrigerant
pressure is changed, as shown in the illustration.
If operation is not as specified, replace the pressure switch.
6.
STOP ENGINE AND SET OFF MANIFOLD GAUGE SET
7.
CONNECT CONNECTOR TO PRESSURE SWITCH