Lexus RX300 (MCU15). Service manual — part 87
AC0S1–02
P19938
Pivot Bolt
Adjusting
Lock Bolt
Adjusting Bolt
AC–16
–
AIR CONDITIONING
DRIVE BELT
LEXUS RX300 (RM785E)
REMOVAL
REMOVE DRIVE BELT
(a)
Loosen the pivot bolt and adjusting lock bolt.
Torque:
Pivot bolt: 56 N·m (570 kgf·cm, 41 ft·lbf)
Adjusting lock bolt: 18 N·m (185 kgf·cm, 13 ft·lbf)
(b)
Loosen the belt tension by adjusting bolt and remove the
drive belt.
AC0S2–02
–
AIR CONDITIONING
DRIVE BELT
AC–17
LEXUS RX300 (RM785E)
INSTALLATION
Installation is in the reverse order of removal (See page AC–16).
AFTER INSTALLATION, CHECK DRIVE BELT’S INSTALLATION CONDITION
I07909
High Pressure
Charging Hose
Low Pressure
Charging Hose
AC0S3–03
N04392
Sleeve
AC–18
–
AIR CONDITIONING
MANIFOLD GAUGE SET
LEXUS RX300 (RM785E)
MANIFOLD GAUGE SET
SET ON
1.
CONNECT CHARGING HOSES TO MANIFOLD
GAUGE SET
Tighten the nuts by hand.
CAUTION:
Do not connect the wrong hoses.
2.
CONNECT QUICK DISCONNECT ADAPTERS TO
CHARGING HOSES
Tighten the nuts by hand.
3.
CLOSE BOTH HAND VALVES OF MANIFOLD GAUGE
SET
4.
REMOVE CAPS FROM SERVICE VALVES ON RE-
FRIGERANT LINE
5.
CONNECT QUICK DISCONNECT ADAPTERS TO SER-
VICE VALVES
HINT:
Push the quick disconnect adapter onto the service valve, then
slide the sleeve of the quick disconnect adapter downward to
lock it.
AC0S4–03
N06553
–
AIR CONDITIONING
MANIFOLD GAUGE SET
AC–19
LEXUS RX300 (RM785E)
SET OFF
1.
CLOSE BOTH HAND VALVES OF MANIFOLD GAUGE
SET
2.
DISCONNECT QUICK DISCONNECT ADAPTERS
FROM SERVICE VALVES ON REFRIGERANT LINE
HINT:
Slide the sleeve of the quick disconnect adapter upward to un-
lock the adapter and remove it from the service valve.
3.
INSTALL CAPS TO SERVICE VALVES ON REFRIGER-
ANT LINE