Toyota FJ Cruiser (GSJ 10, 15 series). Manual — part 10
1GR-FE EMISSION CONTROL – AIR FUEL RATIO SENSOR
EC–21
EC
REMOVAL
CAUTION:
•
Wear protective gloves when removing the sensor.
•
The exhaust pipe assembly is extremely hot
immediately after the engine has stopped.
•
Confirm that the exhaust pipe assembly has cooled
down before removing it.
1.
DISCONNECT CABLE FROM NEGATIVE BATTERY
TERMINAL
2.
REMOVE AIR FUEL RATIO SENSOR
(a) Remove the 3 bolts, then remove the No. 2 exhaust
manifold stay. (for LH Bank)
(b) Disconnect the 2 air fuel ratio sensor connectors.
(c) Using SST, remove the 2 air fuel ratio sensors from
the exhaust manifold.
SST
09224-00010
INSPECTION
1.
REMOVE AIR FUEL RATIO SENSOR
(a) Check the resistance.
(1) Using an ohmmeter, measure the resistance
between the terminals.
Standard resistance
If the result is not as specified, replace the air
fuel ratio sensor.
A128840
A130153
Ohmmeter
A128842E01
Tester Connection
Specified Condition
1 (HT) - 2 (+B)
1.8 to 3.4
Ω at 20°C (68°F)
1 (HT) - 4 (E)
10 k
Ωor higher
EC–22
1GR-FE EMISSION CONTROL – AIR FUEL RATIO SENSOR
EC
INSTALLATION
1.
INSTALL AIR FUEL RATIO SENSOR
(a) Using SST, install the 2 air fuel ratio sensors onto
the exhaust manifold.
SST
09224-00010
Torque: 44 N*m (449 kgf*cm, 33 ft.*lbf)
(b) Connect the 2 air fuel ratio sensor connectors.
(c) Install the exhaust manifold stay with the 3 bolts. (for
LH Bank)
2.
CONNECT CABLE TO NEGATIVE BATTERY
TERMINAL
Torque: 3.9 N*m (40 kgf*cm, 35 in.*lbf)
For LH side
For LH side
SST
A130153E01
A128840
1GR-FE EMISSION CONTROL – HEATED OXYGEN SENSOR
EC–23
EC
ENGINE
1GR-FE EMISSION CONTROL
HEATED OXYGEN SENSOR
COMPONENTS
OXYGEN SENSOR
OXYGEN SENSOR
N*m (kgf*cm, ft*lbf) : Specified torque
44 (449, 33)
44 (449, 33)
A129978E01
EC–24
1GR-FE EMISSION CONTROL – HEATED OXYGEN SENSOR
EC
REMOVAL
1.
DISCONNECT CABLE FROM NEGATIVE BATTERY
TERMINAL
2.
REMOVE HEATED OXYGEN SENSOR
(a) Disconnect the 2 heated oxygen sensors
connectors.
(b) Using SST, remove the 2 heated oxygen sensors
from the exhaust pipe.
SST
09224-00010
INSPECTION
1.
INSPECT HEATED OXYGEN SENSOR
(a) Check the resistance.
(1) Using an ohmmeter, measure the resistance
between the terminals.
Standard resistance
SST
For RH side:
For LH side:
A128844E01
Ohmmeter
A128845E01
Tester Connection
Specified Condition
1 (HT) - 2 (+B)
11 to 16
Ω at 20°C (68°F)
1 (HT) - 4 (E)
10 k
Ω or higher