SsangYong Korando III (2010 year). Service manual — part 423
03-14
2) Voltage Check (with load)
1
Push the load switch to ON (to arrow
direction) direction for less than 5 seconds.
1.
Read the measurement.
2.
Specified
value
7 ~ 9V (Red): Over discharged
or faulty
9 ~ 11V (Yellow): Charging
required
11 ~ 13V: Normal
To identify the battery capacity with the
voltage drop (V) value, discharge the fixed
load capacity (120A) for a certain period (5
seconds).
03-15
0000-00
8. DTC SETTING CONDITIONS
Charge warning lamp ON condition
▶
Turn the ignition ON (Engine stopped)
Open or short circuit of L terminal wiring, open or short internal circuit of alternator (fixed control of
13.8V)
Open or short circuit of F terminal wiring, no feedback output signal
1.
2.
3.
03-16
1. LAYOUT
D20DTF(Low CO2) D20DTF
ECU
Battery sensor (EBS)
Alternator (ALT)
Meter cluster (charge
warning lamp)
03-17
0000-00
2. OPERATING PROCESS
System diagram
▶
Operation
▶
EEM monitors the electric loads and battery conditions and controls the voltage to improve the fuel
economy and battery charging efficiency.
EBS on “-“ terminal of battery sends the battery information (voltage, current, temperature and
SOC) to engine ECU with LIN communication.
Engine ECU outputs the information from EBS and regulating control signal (PWM) according to the
engine load conditions to “L” terminal on alternator.
Engine ECU controls the magnetic resistance between stator coil and rotor coil by controlling the
current in rotor coil according to PWM duty value.
The alternating voltage induced to stator coil is converted to direct voltage by rectifier. And, EBS
outputs the charging voltage to “B” terminal on alternator.
-
-
-
-
-