SsangYong Stavic / SsangYong Rodius (2005 year). Service manual — part 232
33
CHANGED BY
EFFECTIVE DATE
AFFECTED VIN
RK STICS
STAVIC - 2004.09
2C
12) Time Lag Power Window Control
1. The power window is turned off when turning the ignition key to “ON” position.
2. The power window relay is turned “ON” for 90 seconds (T1) when turning the ignition key to “OFF” position.
However, the power window relay stays on for 90 seconds (T2) when the ignition key is turned to “OFF” position
while the door is opened.
3. The power window relay is turned “ON” again for 90 seconds (T2) just for once when opening the door during its
extended operation period of 90 seconds (T1).
4. The power window relay is turned “OFF” when closing the door during its extended operation period of 90 seconds
(T2).
34
CHANGED BY
EFFECTIVE DATE
AFFECTED VIN
RK STICS
STAVIC - 2004.09
2C
13) REKES (Remote Keyless Entry System)
Transmitter
PANIC function is added on the previous version of REKES.
Specification:
Quantity:
CR 2032
1 ea
Door unlock (2-step operation)
Step 1: Unlocking driver’s door
Step 2: Unlocking all doors and tailgate
Door lock button
1. Door locking and theft deterrent armed mode
2. Press door lock button to release.
Panic button: Operates under the theft deterrent
armed mode
Theft deterrent horn: Sounds approx. 27 seconds
35
CHANGED BY
EFFECTIVE DATE
AFFECTED VIN
RK STICS
STAVIC - 2004.09
2C
Receiver
1. Operating requirements
- IGN key = OUT (removed)
2. Code registration requirement
- After connecting the B+ to external coding terminal (applying battery voltage)
Transmitter Code Registration
- Only one transmitter code can be registered.
- The received code cannot be output during the registration.
1. Coding terminal: OFF à ON (applying battery voltage)
2. Press LOCK, UNLOCK or PANIC switch on the transmitter.
3. Outputs hazard warning flasher for 0.5 seconds (once) and horn for 0.04 seconds (once) during registration.
4. Code output requirements
- The system outputs the function code when the CUSTOM and ID code are correct and the Rolling code is within
operating range while the ignition key is removed and the coding terminal is turned off (grounded).
- Available function code: LOCK / UNLOCK / PANIC
36
CHANGED BY
EFFECTIVE DATE
AFFECTED VIN
RK STICS
STAVIC - 2004.09
2C
14) Theft Deterrent
Description of Burglar Alarm Function
1) Armed mode activation requirements
1. The “LOCK” output is “ON” when receiving the “LOCK” signal from transmitter while the ignition key is removed and
all doors are closed. The armed mode is activated when the door lock switch is locked (theft deterrent horn output:
once, hazard relay output: twice).
2. The theft deterrent horn and hazard relay outputs are “ON” when receiving the “LOCK” signal from the remote
control key again in armed mode (theft deterrent horn output: once, hazard relay output: twice).
3. When receiving “LOCK” signal from the remote control key while any of doors is not closed, only the “LOCK” output
can be done and then activates the armed ready mode (without theft deterrent horn and hazard warning flasher). At
this moment, if the ignition key is in the ignition switch, the door unlock switch is turned “ON” or the door lock
switch is unlocked (after 0.6 seconds), cancels the armed mode and activates the normal mode. However, in these
cases, if closing the door and locking the door lock switch, the theft deterrent horn outputs once and the hazard
warning flasher outputs twice and then activates armed mode.
4. When the door is not opened or the ignition key is not inserted into ignition switch for 30 seconds after receiving
“UNLOCK” signal, outputs “LOCK” and then activates armed mode (RELOCK operation). Also, at this moment, the
system outputs the theft deterrent horn and hazard warning flasher.
5. The armed mode will not be activated except above conditions.
Ex) The armed mode will not be activated when the door is locked by the ignition key.
Tx SIGNAL
NO SIGNAL
ENTRANCE
DOOR SW
ENTRANCE
DOOR
LOCK SW
ARMED MODE
OTHERS
OPERATION