Jaguar X-Type Sedan and Estate (Wagon). Service manual — part 489
Published: 11-May-2011
Climate Control System - General Information - Refrigerant System Tests
General Procedures
1.
W ARNING: Use extreme care and observe all safety precautions
related to the use of refrigerants. The A/C refrigerant analyzer must be
used before the recovery of any vehicle's A/C refrigerant. Failure to do so
puts shop bulk refrigerant at risk of contamination. If the vehicle A/C
refrigerant is contaminated, refer the customer to return to the repair
facility that carried out the last A/C repair. If the customer wishes to pay
the additional cost, use the A/C recovery equipment that is designated for
recovering contaminated A/C refrigerant. All contaminated A/C refrigerant
must be disposed of as hazardous waste. For all equipment, follow the
equipment manufacturers procedures and instructions. Failure to follow
this instruction may result in personal injury.
• NOTE: Jaguar Cars Ltd supports the efficient usage, recovery and
recycling of the refrigerant used in passenger car air conditioners. Jaguar
Cars Ltd recommends the use of UL-approved recovery/recycling device
such as R-134a A/C refrigerant center (which meets SAE Standard J 1991)
during any A/C system repair and recharge procedure which requires that
the system be evacuated.
Use R-134a A/C refrigerant centre to evacuate and recover the A/C
system.
Follow the equipment manufacture procedures and instructions for
use of equipment.
Published: 11-May-2011
Air Distribution and Filtering - Air Distribution and Filtering
Description and Operation
Item
Part Number
Description
1
—
Left-hand side register
2
—
Center register
3
—
Right-hand side register
4
—
Right-hand side front floor duct
5
—
Right-hand side rear floor duct
6
—
Left-hand side rear floor duct
7
—
Left-hand side front floor duct
The purpose of the air distribution system is to route air to the designated registers. This is accomplished when air enters the plenum
through the fresh/recirculated air inlet and is routed to the desired outlets by use of distribution doors. The incoming stream of fresh air is
passed through a pollen filter.
The air distribution system consists of the heater core, air conditioning (A/C) evaporator core, A/C blower motor and all of the distribution
doors. All of the air is mixed and distributed inside of the plenum chamber, depending on the distribution door positions.
Air ducts route air to specified areas of the air distribution system. These areas are the floor ducts, side window registers, windshield
demister, instrument panel vents and instrument panel center registers.
Published: 11-May-2011
Air Distribution and Filtering - Air Distribution and Filtering
Diagnosis and Testing
For additional information, refer toSection
412-00 Climate Control System - General Information
Published: 11-May-2011
Air Distribution and Filtering - Center Registers
Removal and Installation
Removal
1. Remove the instrument panel veneer trim.
2. Remove the center registers.
Remove the center register retaining screws.
Installation
1. To install, reverse the removal procedure.