JAC S2. Elctrical Wiring diagrams — part 3
Air-conditioning Device
Air-conditioning Device
24
No.
Tool No.
Tool name
Outside drawing
Use
10
Seal protector device
11
50 pounds recycling tanks
12
Pressure test adapter
Connecting A/C
pressure tester and
A/C pipes
13
A/C system lip seal removal tool
Removal A/C
system lip seal
14
O-type seal removal tool
Remove O-type
seal ring
15
Valve core removal and installation tool
Remove and
install valve core
16
O-type seal ring installation tool
Install O-type seal
ring
17
Spring clip pliers
Remove and
install spring clip
-------------------------------------------------------------------------------------------------------------------------------------------------------------
Air-conditioning Device
Air-conditioning Device
25
No.
Tool No.
Tool name
Outside drawing
Use
18
Spring clip pliers
Remove and
install spring clip
19
Refrigerant recycle\ regeneration and
refilling system
Recycle and fill
refrigerant
20
Passive test lamp
A/C system
leakage inspection
-------------------------------------------------------------------------------------------------------------------------------------------------------------
Air-conditioning Device
Air-conditioning Device
26
II、Troubleshooting
Troubleshooting List
No.
Fault Phenomenon
Fault reason analysis
Solution
Remark
1
A/C system has no
refrigerant
System exists leakage
Check with eyes:
1. Observe whether there is oil stain in connection parts of all
components; if any, it indicates there is leakage here. Spread
suds to suspected part and observe whether there is bubble.
2. Observe whether there is abnormal failure, whether there is
scraping, flattening and bruise on surface of condenser and
evaporator core.
With vacuumizing mode, listen to the part position if there is
“zizi” sound, which indicates the leakage.
Check with instrument:
1. Electronic leak detector with high sensitivity;
2. Dye-guided detection method
2
System
refrigeration oil
not right amount
Replace
system
component, fill or
reduce according to
rules
1. Firstly ensure specification of refrigeration oil, can’t
be mixed; generally using specification: PAG
2. After recycling refrigerant, replenish about 30g
refrigeration oil
3. Replace compressor, pour out all refrigeration oil in
compressor and fill the same refrigeration oil with
replaced compressor
4. Replace pipe: replenish about 30g refrigeration oil
5. Replace condenser: replenish about 60g refrigeration
oil
6. Replace evaporator: replenish about50g refrigeration
oil
7. Replace dryer: replenish about 10g refrigeration oil
3
Blowing
rate
abnormal
A/C has no wind
Circuit fault
Refer to “Blower not work”
Machinery fault
1. Blower motor damaged, replace motor
2. Temperature air door mechanism damaged, and
cannot adjust air door to refrigeration state
3. A/C controller damaged, replace A/C control mo dule
4. Speed regulating resistance damaged, replace speed
control module
A/C blowing rate
small
1. Voltage not enough, check power supply
2. Whether air duct is blocked, whether grille is fully
opened
3. Check whether face air blow has leakage
4. Speed control module fault, replace speed control
module
5. Whether air filter has excessive windage, whether
there is dust and foreign matters blocked
6. Blower motor rotates in reverse direction, adjust
positive and negative electrode of connector
4
A/C
not
refrigerate
System
has
no
refrigerant
Refer to “A/C system has no refrigerant ”
Not blow
Refer to “Blowing rate abnormal ”
Compressor
not
work
Circuit fault
Refer to “Compressor not work”
Machinery fault
1. Drive belt broken, replace
2. Compressor internal fault, replace
5
A/C refrigeration
is not good
Refrigerant
not
enough
1. Check whether pressure is in normal value range; if
lack of refrigerant, refill it.
2. Check whether system has micro leakage
Refrigeration oil too
1. Discharge redundant refrigeration oil, and refill the
-------------------------------------------------------------------------------------------------------------------------------------------------------------
Air-conditioning Device
Air-conditioning Device
27
No.
Fault Phenomenon
Fault reason analysis
Solution
Remark
much
satisfactory amount of refrigeration oil
Compressor
is
abnormal
1. Compressor belt or clutch slips
Blowing
rate
is
small
Refer to “Abnormal blowing rate”
Abnormal pressure
High pressure is lower than normal value, low pressure
is lower than normal value
1. Expansion valve is blocked, clear obstructions
2. Opening degree of expansion valve is not enough,
adjust expansion valve or replace
3. Refrigerant is little, add refrigerant
High pressure is higher than normal value, low pressure
is higher than normal value
1. Condenser radiating is not good; Check condenser
fan and replace faulted
2. Refrigerant is too much, release some
High pressure is lower than normal value, low pressure
is higher than normal value
1. Compressor malfunctions, lack of capacity, needs to
be replaced
2. Refrigerant not enough, add refrigerant
High pressure is higher than normal value, low pressure
is lower than normal value
1. There is impurity blocking in the system
6
A/C system no
heating
Heater core has no
hot water
Heating pipe gets blocked, clear obstacle
A/C
not
blowing
wind
Refer to “Blowing rate abnormal ”
Controller fault
Temperature regulation of controller damaged, and
can’t adjust temperature air door to maximum heating,
replace controller
7
A/C
system
heating is not
good
Heating
water
circulation
not
enough
Check whether engine coolant supply is insufficient,
engine failure
Poor
circulation
inside heater core
Clear obstacle in heater core, or replace heater
Blowing
rate
is
small
Refer to “Blowing rate abnormal ”
Mode air door is
wrong
Temperature air door’s rotation is not in place, and
there is a mix of cold and hot
8
A/C system has
abnormal sound
Compressor
has
abnormal sound
Open A/C, compressor works; check whether there is
fractive sound in clutch; if an y, please replace
compressor
Pipe
expansion
valve has abnormal
sound
Start the A/C, check if there is flowing “chirps” sound
in the expansion valve. Adjust the expansion valve and
replace it.
Air door mechanism
has abnormal sound
If there is resistance when adjusting the damper bodies;
whether there is "ticking" or "giggle" sound; if there is
such phenomenon, smear lubrication oil in the damper
body or replace body parts.
Motor damaged
Replace motor
Temperature
air
Replace temperature air door mechanism
-------------------------------------------------------------------------------------------------------------------------------------------------------------
Air-conditioning Device
Air-conditioning Device
28
No.
Fault Phenomenon
Fault reason analysis
Solution
Remark
door
mechanism
damaged, and can’t
adjust air door to
refrigeration state
Blower
has
abnormal sound
There is abnormal sound in blower
1. . A "humming" sound ; confirm if the motor rotates
reversely; adjust plug-line;
2. "Creak" or "Zizi" sound; the motor is damaged, and
replace the motor;
3. "Pop" sound; if there is a foreign body in the volute,
remove and check the volute.
Blower is not installed firmly, resulting in vibration and
abnormal sound.
There is water sound
in heater core
1. 1. Idling and stepping on the accelerator (compressor
does not start) to the degree that the condenser fan
rotates at high speed;
2. Continue to step on the accelerator to the degree that
the engine speed exceeds 5000 rpm with the duration of
one minute;
3. Stop accelerating, idle and drastic acceleration to
confirm whether there is still water flow sound; if so,
follow step ② until no sound of water.
9
A/C
system
has
peculiar smell
Filter mildew
Remove the filter to check if the surface has serious
pollution, and timely replace it when necessary.
Radiator surface has
been polluted
Whether the surface of evaporator and heater contains
oil in production; if it has, remove and clean it.
Poor
drainage
of
condenser water
Condensate water cannot be excluded entirely, and
there is water in the case, resulting in deteriorating;
replace the outlet location.
(I)Troubleshooting Flow Chart
Blower not work
Step
Check content
Solution
Judgement
specification
Next step
Yes
No
1
Check
blower
relay fuse
Remove blower relay fuse IF37, and
measure whether blower relay fuse IF37
is fused by multimeter.
Whether fuse is
fused?
Maintain
fuse
short
circuit fault
and replace
fuse
Go to
step 3
2
Check
voltage
value of blower
relay
control
circuit
Measure voltage value between blower
relay ER2-86 terminal and reliable
ground.
Voltage standard
value: 11~14V
Next step
Replac
e relay
3
Check blower fuse
Remove blower relay fuse ESF04, and
measure whether blower relay fuse ESF04
is fused by multimeter.
Whether fuse is
fused?
Maintain
fuse
short
circuit fault
and replace
fuse
Go to
step 3
4
Check
voltage
value of blower
relay
controlled
circuit
Measure voltage value between blower
relay ER2-30 terminal and reliable
ground.
Voltage standard
value: 11~14V
Next step
Mainta
in
failure
circuit
-------------------------------------------------------------------------------------------------------------------------------------------------------------
Air-conditioning Device
Air-conditioning Device
29
Step
Check content
Solution
Judgement
specification
Next step
Yes
No
5
Check
connected
circuit
between
blower relay and
blower
wiring
harness
Measure resistance value between blower
wiring harness connector M44 -2 terminal
and ER2-87 terminal.
Standard
resistance value:
less than 1Ω
Next step
Mainta
in
failure
circuit
6
Check
connected
circuit
between
blower
wiring
harness and A/C
control
panel
wiring
harness
connector
Measure resistance value between blower
wiring harness connector M44 -1 terminal
and A/C control panel wiring harness
connector M30-4 terminal.
Standard
resistance value:
less than 1Ω
Next step
Mainta
in
failure
circuit
7
Replace blower
Remove blower, and install new blower.
Adjust blowing rate button to check
whether blower works normally.
Blower
works
normal
System
is
normal
Next
step
8
Ensure system is
normal
Compressor not work
Step
Check content
Solution
Judgement
specification
Next step
Yes
No
1
Check
A/C
compressor
relay
fuse
Remove A/C compressor relay fuse EF02,
and check whether blower relay fuse
EF02 is fused.
Whether fuse is
fused?
Maintain
fuse circuit
short circuit
fault,
and
replace fuse
Go
to
step 3
2
Check
voltage
value
of
A/C
compressor
relay
control circuit
Check voltage value between blower
relay ER2-86 terminal and reliable
ground.
Voltage standard
value: 11~14V
Next step
Replac
e relay
3
Check
A/C
compressor fuse
Remove A/C compressor fuse EF04, and
check whether blower relay fuse EF04 is
fused.
Whether fuse is
fused?
Maintain
fuse circuit
short circuit
fault,
and
replace fuse
Go
to
step 3
4
Check
voltage
value
of
A/C
compressor
relay
controller circuit
Check voltage value between blower
relay ER05-30 terminal and reliable
ground.
Voltage standard
value: 11~14V
Next step
Mainta
in
failure
circuit
5
Check
circuit
between
A/C
compressor
relay
and
A/C
compressor wiring
harness connector
Measure resistance value between A/C
compressor connector B05 -1 terminal and
ER05-87 terminal by multimeter .
Standard
resistance value:
less than 1Ω
Next step
Mainta
in
failure
circuit
6
Check
circuit
between
A/C
compressor
relay
and ECU wiring
harness connector
Measure resistance value between A/C
compressor relay ER05 -86 terminal and
ECU wiring harness connector A22 -10
terminal by multimeter.
Standard
resistance value:
less than 1Ω
Next step
Mainta
in
failure
circuit
7
Replace ECU
Disconnect ECU wiring harness, remove
ECU, and replace new ECU. Check
whether A/C compressor works normally.
Whether
compressor
works normally?
System
is
normal
Next
step
-------------------------------------------------------------------------------------------------------------------------------------------------------------
Air-conditioning Device
Air-conditioning Device
30
Step
Check content
Solution
Judgement
specification
Next step
Yes
No
8
Replace
A/C
pressure switch
Disconnect
pressure
switch
wiring
harness connector, and replace A/C
pressure switch/
Whether
compressor
works normally?
System
is
normal
Next
step
9
Check
circuit
between
A/C
pressure
switch
wiring
harness
connector and ECU
wiring
harness
connector
Use multimeter to respectively measure
resistance value of A/C pressure switch
wiring harness connector E15 -2 terminal
and ECU wiring harness connector A22 -
79 terminal, A/C pressure switch wiring
harness connector E15 -4 terminal and
ECU wiring harness connector A22 -40
terminal.
Standard
resistance value:
less than 1Ω
Next step
Mainta
in
failure
circuit
10
Check
circuit
between
A/C
pressure
switch
wiring
harness
connector and A/C
control
panel
wiring
harness
connector
Use multimeter to respectively measure
resistance value of A/C pressure switch
wiring harness connector E15 -1/E15-3
terminal and A/C control panel wiring
harness connector M29 -23 terminal.
Standard
resistance value:
less than 1Ω
Next step
Mainta
in
failure
circuit
11
Check
circuit
between evaporator
temperature sensor
wiring
harness
connector and A/C
control
panel
wiring
harness
connector
Use multimeter to respectively measure
resistance
value
of
evaporator
temperature
sensor
wiring
harness
connector M40-1 terminal and A/C
control panel wiring harness connector
M29-8 terminal, evaporator temperature
sensor wiring harness connector M40 -2
terminal and A/C control panel wiring
harness connector M29 -9 terminal.
Standard
resistance value:
less than 1Ω
Next step
Mainta
in
failure
circuit
12
Check
evaporator
temperature sensor
Measure resistance value of evaporator
temperature sensor by multimeter.
Judge
whether
resistance value
corresponding to
evaporator
temperature
sensor
temperature-
resistance list?
Next step
Replace
evaporator
temperature
sensor
13
Replace
A/C
control panel
Remove fixed bolts of A/C control panel,
disconnect A/C control panel wiring
harness connector, and replace new A/C
control panel
Whether
compressor
works normally?
System
is
normal
Next step
14
Replace
A/C
compressor
Disconnect A/C pipe, remove fixed bol ts
of
compressor,
and
replace
A/C
compressor
Whether
compressor
works normally?
System
is
normal
Next step
15
Ensure system is
normal
-------------------------------------------------------------------------------------------------------------------------------------------------------------
Air-conditioning Device
Air-conditioning Device
31
III、A/C Check and Filling Refrigerant
(I)Special Tool
No.
Tool No.
Tool name
Tool diagram
1
Refrigerant recycling/ regeneration, refilling
system
2
Passive test lamp
3
R-134A manifold gauge
4
50 pounds recycling tank
5
Pressure test adapter
6
Microthermometer
-------------------------------------------------------------------------------------------------------------------------------------------------------------
Air-conditioning Device
Air-conditioning Device
32
(II)Refrigerant Filling and Discharging
1. Install refrigerant filling instrument
1). Close manual valves at both ends of refrigerant filling instrument.
2). The filling pipe of the refrigerant filling instrument is installed in joints. Low-pressure pipe to the low pressure nozzle and
high pressure pipe to the high-pressure nozzle. Tighten the nut by hands after connection.
Low
High
Close
Open
2. Operations of discharging refrigerant
1). Connect the refrigerant filling instrument to the system.
2). Put a clean rag in the open part of central hose.
3). Gradually open the high pressure manual valve to discharge refrigerant.
△ Caution Exhausting gas velocity too fast may result in the discharging of the refrigeration oil from the compressor.
4). Check if there is the trace of refrigeration oil on the rag. If there is the trace, slightly close the manual valve.
5). When the filling instrument ruler decreases to 3.5kg/c㎡, slowly open the low pressure manual valve.
6). To reduce the system pressure, slowly open the high pressure and low pressure manual valve until the ruler indicates 0kg/c
㎡.
3. Vacuum operation for refrigeration system
△ Caution System must be vacuumized after discharging refrigerant. This operation is supposed to exclude the air and
moisture in the system, and it should be started in 15 minutes after all the parts are installed.
1). Confirm if the engine stays in “shut down”.
2). Connect the filling instrument to the compressor contact joint, and
close the two ends.
3). Confirm if the refrigerant is excluded from the system.
4). Central pipe is connected to the intake port of the vacuum pump.
5). Open the high pressure/low pressure valve of the filling instrument
after operating the vacuum pump.
6). After 10 minutes, the low pressure detector scale should be higher
than 0.96kg/c㎡ vacuum. Otherwise, the system has leakage and
should be repaired as following steps.
-Use refrigerant container filling system.
-Use leakage detector to check the leakage. If the leakage if detected,
repair it.
-Exclude the refrigerant and vacuumize the system.
- If the leakage does not occur, continue to vacuumize.
7). Operate the vacuum pump again.
8). Filling instrument scale for both ends should keep 0.96kg/c㎡ vacuum.
9). Continue to vacuumize until the ruler indicates 0.96kg/c㎡.
10). About 15 minutes after the implementation of vacuum operation, close the pressure valve of the filling instrument and stop
vacuumizing; separate pipes from the pump. In this way, refrigerant can be added.
Low
High
Close
Close
Air
Vacuum pump
-------------------------------------------------------------------------------------------------------------------------------------------------------------
Air-conditioning Device
Air-conditioning Device
33
4. Use refrigerant control valve
1). Before the valve is connected to the refrigerant container, completely turn the handle counterclockwise.
2). Turn counterclockwise until the disc reaches the highest position.
3). After connecting of the central pipe to the valve device, rotate the disc clockwise by hand.
4). Turn the handle clockwise and dill hole in the upper portion of
the sealing part.
5). Loosen the nuts connecting the filling instrument center
connector and pipe.
6). After a few seconds of exhaust, tighten the nut.
5. Adding refrigerant (Gaseous state)
△ Caution This operation is by means of the device on low
pressure side to add the gaseous refrigerant into the system. At this time the refrigerant
container should be put vertical so that the gaseous refrigerant would flow into the system.
1). Install the refrigerant container on the adjusting valve.
2). Open the low pressure valve; adjust the valve until the low pressure scale stays below 4.2kg/m
2
.
3). Start the engine and start the air condition.
△ Caution To prevent the liquid refrigerant flows into compressor through the intake port, put the
container vertical.
4). When add the regulated amount of refrigerant, close the low
pressure valve.
Regulated amount of filling refrigerant: 460±20g
5). If the refrigerant filling speed is too slow, you can put the
container into a container of water of about 40 ℃.
△ Caution Under any circumstances, do not keep the water
heated to above 52 ℃, and hot light should not
touch the container.
Low
Close
Open
Refr
iger
ant
Refrig
erant
Refri
gera
nt
Soak into water to
about 40℃
-------------------------------------------------------------------------------------------------------------------------------------------------------------
Air-conditioning Device
Air-conditioning Device
34
6. Adding refrigerant (liquid state)
△ Caution This operation is by means of high pressure side filling. Upend the refrigerant container so that
the refrigerant would flow into the system.
1). After the system is vacuumized, completely close both ends of high/low pressure valve.
2). Install the adjusting valve of refrigerant container.
3). Upend the container after the high pressure valve is fully opened.
4). The exclude pressure will increase when the system is over filled. Therefore, when measure the refrigerant weight, fill with
correct amount and close the high pressure valve.
Regulated amount of filling refrigerant: 460±20g
5). After adding regulated amount of refrigerant, close the filling instrument valve.
6). Use leakage detector to check if there is leakage.
△ Caution When use high pressure side filling, the engine will not be started. By use of liquid refrigerant
filling, low pressure valve cannot be opened. Performance test should be conducted before
separating the filling instrument.
-------------------------------------------------------------------------------------------------------------------------------------------------------------
Air-conditioning Device
Air-conditioning Device
35
IV、A/C Controller Assembly
(I)Removal
1. Open the engine compartment hood.
2. Disconnect the negative cable of the battery. Refer to “Disconnection and connection of battery electrode”
3. Disassemble the air condition control module assembly.
1). Pry out the air condition control module;
2). Disconnect the wiring harness connector of the air condition control module assembly;
3). Remove the air condition control module;
(II)Installation
1.
Install air condition control module assembly
1). Connect the wiring harness connector of the air condition control module assembly;
2). Press the air condition control module with the installation panel assembly into the installation hole and make sure it is in
place;
2. Connect the cable to the negative pole of the battery;
3. Close the engine compartment hood;
-------------------------------------------------------------------------------------------------------------------------------------------------------------
Air-conditioning Device
Air-conditioning Device
36
V、Speed Regulating Resistance
(I)Removal
1. Open engine cabin cover;
2. Disconnect battery negative electrode; refer to “Disconnection and connection of battery electrode”
3. Remove glove box assembly; refer to “Glove box assembly”;
4. Remove speed regulating resistance;
1). Disconnect wiring harness connector ① of speed regulating
resistance;
2). Remove 2 fixed bolts ②;
3). Take down speed regulating resistance;
(II)Installation
1. Install speed regulating resistance
1). Place speed regulating resistance to installation position, and tighten
2 fixed bolts ②;
2). Connect wiring harness connector ① of speed regulating
resistance;
2. Install glove box assembly;
3. Connect battery negative electrode;
4. Close engine cabin cover;
-------------------------------------------------------------------------------------------------------------------------------------------------------------
Air-conditioning Device
Air-conditioning Device
37
VI、Exhausting Pipe Assembly
(I)Removal
1. Open engine cabin cover
2. Remove intake hose; refer to “intake hose assembly”
3. Recycle refrigerant, refrigeration oil; refer to “Refrigerant, refrigeration oil”
4. Remove exhausting pipe assembly
1). Remove 1 fixed nut of exhausting pipe assembly and condenser assembly;
2). Remove 1 fixed bolt of exhausting pipe assembly and
compressor assembly;
3). Take down exhausting pipe assembly;
(II)Installation
1. Install exhausting pipe assembly
1). Place exhausting pipe assembly to installation place, and
tighten 1 fixed bolt of exhausting pipe assembly and
compressor assembly;
2). Tighten fixed nut of exhausting pipe assembly and condenser assembly;
2. Fill refrigerant and refrigeration oil
3. Install intake hose
4. Close engine cabin cover
-------------------------------------------------------------------------------------------------------------------------------------------------------------
Air-conditioning Device
Air-conditioning Device
38
VII、Pipe and Expansion Valve Assembly
(I)Removal
1. Open engine cabin cover
2. Disconnect battery negative electrode; refer to “Disconnection and connection of battery electrode”
3. Remove intake hose; Refer to “Intake hose assembly”
4. Recycle refrigerant, refrigeration oil; Refer to “Refrigerant and refrigeration oil”
5. Remove pipe and expansion valve assembly
1). Disconnect wiring harness connector of ternary pressure switch;
2). Remove 2 fixed bolts of expansion valve assembly and A/C
host;
3). Remove fixed bolt of pipe and expansion valve assembly and
vehicle body;
4). Remove fixed bolt of pipe and expansion valve assembly and
right front suspension;
5). Remove fixed bolt of pipe and expansion valve assembly
and condenser assembly;
6). Remove fixed bolt of pipe and expansion valve assembly and compressor assembly;
7). Take down pipe and expansion valve assembly;
-------------------------------------------------------------------------------------------------------------------------------------------------------------
Air-conditioning Device
Air-conditioning Device
39
(II)Installation
1. Install pipe and expansion valve assembly
1). Place pipe and expansion valve assembly to installation position, and tighten fixed bolt of compressor
assembly;
2). Tighten fixed nut of pipe and expansion valve assembly and condenser assembly;
3). Tighten fixed bolt of pipe and expansion valve assembly and right
front suspension.
4). Tighten fixed bolt of pipe and expansion valve assembly and
vehicle body suspension.
5). Tighten 2 fixed bolts of expansion valve assembly and A/C host.
6). Connect wiring harness of ternary pressure switch.
2. Fill refrigerant, refrigeration oil
3. Install intake hose
4. Connect battery negative electrode
5. Close engine cabin cover
-------------------------------------------------------------------------------------------------------------------------------------------------------------