Dacia Pick-Up 1304/1305/1307. Manual — part 43
19
COOLING - EXHAUST - FUEL TANK
19 - 1
Cooling system with under pressure liquid in the circuit, mechanical fan driven by belt
and radiator core type, with vertical basins.
COOLING FLUID QUANTITY
E
NG INE
Q
UANTITY
Q
UALITY
P
ARTICULARITIES
R
EMARK S
( litres )
102; 106
6
Type C
Mixture:
Protection up to - 40
0
50% concentrated antifreeze
Type D
+
GLACEOL RX
50% water distilled
C
O UNTRY
TYPE
O
PENING
START
(
0
C ) O
PENING
END
(
0
C ) B
O RE
( mm )
Warm countries
76
87
7
Cold and temperate
87
100
7,5
countries
NOTE:
The vehicles, which are using the type D cooling fluid, have a label stacked on the
expansion vessel as follows:
ATTENTION !
Use only cooling fluid type DACIA GLACEOL RX type D.
The D-type antifreeze has a yellow colour.
For the engines variants (with type C antifreeze) it is forbidden the use of type D antifreeze
because the type D antifreeze is damaging the cooper gaskets from the cylinders jackets
lower part and compromising the sealing.
It is forbidden the use of type C antifreeze for the engines with cooling fluid type D.
THERMOSTAT
CHARACTERISTICS
COOLING - EXHAUST - FUEL TANK
19
19 - 2
FILLING AND AERATION OF THE COOLING SYSTEM
Check :
- the tightness of the rings;
- the tightness of the draining plugs from the engine block and from the radiator.
Dismount the radiator plug and mount in its place the MOT 401 filling device.
Completely open the air conditioning radiator tap.
Open the water pump and the air conditioning radiator hose purges.
Fill the expansion vessel 30 mm over the maximum level mark.
Lock the radiator - expansion vessel hose by means of the MOT 453 device.
Pour fluid in the device and fill the radiator and the circuit.
Start the engine ,accelerate it up to about 1500 rpm.
Continue the filling of the circuit till the fluid flows in a continuous jet without air
bubbles, through the aeration purges.
In this situation,close the two purges.
Dismount the device,fill the radiator and mount the plug.
Dismount the MOT 453 device.
Check the fluid level in the expansion vessel.
19
COOLING - EXHAUST - FUEL TANK
19 - 3
The cooling circuit is filled with a fluid which ensures the protection against frost,up to
- 40º C.
The fluid is made up of a mixture of distilled or de mineralised water and antifreeze
fluid as follows:
- for a protection up to - 21º = 35 % concentrate antifreeze fluid + 65 % distilled
water.
- for a protection up to - 40º = 50 % concentrate antifreeze fluid + 50 % distilled
water.
The protection temperature of the fluid is decreasing in case antifreeze fluid rate is
over 60%.
Remove the radiator plug and take out a certain quantity of the liquid.
Read on densimeter or refractometer scale,the protection temperature of the liquid.
Depending the liquid temperature,perform the necessary corrections as per bellow table:
CONTROL
COOLING - EXHAUST - FUEL TANK
19
19 - 4
E
XEMPLE
The cooling fluid temperature during the measurements must be aprox. 40
0
C
.
- the cooling fluid temperature: 40
0
C
.
- the protection temperature red on thermal densimeter: - 15
0
C
.
In order to have a protection of up to - 21
0
C
, take out 0,7 l of fluid and put in 0,7 l of
pure a antifreeze.
In order to have a protection of up to - 40
0
C
, take out 1,9 l of fluid and put in 1,9 l of
pure antifreeze.
IMPORTANT:
Do not use for cooling purpose water without antifreeze fluid addition. The water
pump may be thus damaged.
Protection up to - 21
0
C
Warm countries
The value of protection
temperature red on
thermal densimeter
The fluid quantity
(liters) which is replaced
with concentrated
antifreeze
- 5
0
C
- 10
0
C
- 15
0
C
- 20
0
C
1,6
1,1
0,7
0,2
Protection up to - 40
0
C
Cold countries
- 5
0
C
- 10
0
C
- 15
0
C
- 20
0
C
- 25
0
C
- 30
0
C
- 35
0
C
2,6
2,3
1,9
1,6
1,2
1,0
0,5
CHECKING OF THE COOLING FLUID CONCENTRATION
The fluid quantity
(liters) which is
replaced with
concentrated antifreeze
The value of protec-
tion temperature red
on thermal densimeter
CONTROL
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.