Daewoo Korando. Manual — part 318
7B/C-20 MANUAL & SEMIAUTO-HVAC
HEATER AND AIR CONDITIONER CONTROL BOX
1 Blower Switch
2 Recirculation Switch
3 Mode Switch
4 A/C Switch
5 Temperature Control Lever
6 In-vehicle Sensor
MANUAL
SATC
MANUAL & SEMIAUTO-HVAC 7B/C-21
Removal & Installation Procedure
1. Remove the switch panel.
Notice
Be careful not to damage the switch panel.
2. Remove the fixing screws (4 screws) of the control box.
3. Disconnect the wire connectors and remove the control box.
4. Installation is reverse order of the removal.
SECTION 7D
FULL AUTOMATIC TEMPERATURE
CONTROL HEATING, VENTILATION AND
AIR CONDITIONING SYSTEM
Specifications . . . . . . . . . . . . . . . . . . . . . . . . 7D-1
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 7D-1
Service Specifications . . . . . . . . . . . . . . . . . . . 7D-3
Schematic and Routing Diagrams . . . . . . . . 7D-4
Circuit Diagram . . . . . . . . . . . . . . . . . . . . . . . . 7D-4
FATC Block Diagram . . . . . . . . . . . . . . . . . . . . 7D-5
Component Locator . . . . . . . . . . . . . . . . . . . 7D-6
TABLE OF CONTENTS
Ventilation System . . . . . . . . . . . . . . . . . . . . . . 7D-6
Function Description . . . . . . . . . . . . . . . . . . . . 7D-7
Diagnosis . . . . . . . . . . . . . . . . . . . . . . . . . . . 7D-8
Diagnosis Test . . . . . . . . . . . . . . . . . . . . . . . . 7D-8
Maintenance and Repair . . . . . . . . . . . . . . 7D-11
FATC Control Panel . . . . . . . . . . . . . . . . . . . 7D-11
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . 7D-15
FATC (Full Automatic Temperature Control) is full automatic heater and airconditioning system that detects
incar temperature, ambient temperature, sun load and coolant temperature and controls airconditioner system
blowing capacity, outlet temperature and intaking/outlet mode to maintain interior comfort.
SPECIFICATIONS
SPECIFICATIONS
Application
Core Size (LxWxT)
Core Type
Expansion Valve Type
Thermostat
Resister Type
Cooling Capacity
Description
237.0x232.0x92.0
Aluminum plate
Angle
ON:4.5±0.6°C, OFF:1.5±0.6°C
Aluminum plate
4,300 Kcal/h(AT 420 CMH)
Evaporator Unit
Application
Capacity
Type
Description
650-750 g
R134a
Refrigerant
7D-2 FATC-HAVC
Application
Size (WxHxT)
Capacity
Type
Description
650x339.2x22.0
11,000 Kcal/h
Parallel Flow
Condenser
Application
Material
Capacity
Desiccant
Description
Aluminum
250cc
XH-9 or equivalent 35g
Receiver Drier
Application
Motor Type
Motor Size
Description
Magnetic
f
70 x 145
Blower Unit
Application
Replacement
Description
Every 10,000 km (replace earlier if air pollution is heavy)
Air Filter
Application
Model
Type
Displacement (cc/rev.)
Pulley
Oil
Description
FK-II(DKV 14C)
Vane rotary
140.5
f
143.0
ZXL 200 PG (PAG Oil)
Compressor
Application
Heater Core Type
Heating Capacity
Heater Core Size (LxWxT)
Description
2-ROW
4,600 Kcal/h (AT 300 CMH)
219.5 x 151.8 x 52
Heater Unit
Application
Type
High (OFF)
Low (ON)
Description
Direct
OFF : 27±2Kgf/cm
2
, DIFF : 6±2Kgf/cm
2
OFF : 1.8±2Kgf/cm
2
, ON : 1.9±0.3Kgf/cm
2
Pressure Switch