REMOTE KEYLESS ENTRY AND ANTI-THEFT SYSTEM 9T-9
Characteristic Signal
l
Prepare The Burglar Alarm
1. It is possible to prepare the burglar alarm only when the
door is locked by REKES transmitter.
If the door is lock by key, the burglar alarm can’t operate.
2. When the ignition key is removed and all doors and hood
are closed, all lock switches on doors must be changed
from “ON” to “OFF” within 0.5 second after the locking signal
turns back from “LOW” to “HIGH”.
3. The system must prepare the burglar alarm within 0.35
second after all lock switches were changed from “ON” to
“OFF”.
4. If the system prepare the burglar alarm, siren will operate
for 0.05second and the tail lamp will light up twice for 0.5
second.
5. Character Signal : Right Picture
6. Time Interval
T1 : 0.05 ± 0.02sec.
T2 : within 0.25sec.
T3 : 0.5 ± 0.1sec.
T4 : within 0.5sec.
T5 : within 0.35sec.
T6 : 0.05 ± 0.01sec.
T7,T8 : 0.5 ± 0.1sec.
l
Operate The Burglar Alarm
1. Burglar alarm must operate immediately when the door,
tailgate or hood is opened with improper ways after all doors
and hood were closed and continued this status for 2
seconds.
2. Siren will operate three series of warning for 30 second’s
“ON” and 10 second’s “OFF”.
3. If this warning condition is completed, the system block up
the current for starting motor by running the start protection
relay.
4. If the tailgate is opened by key when the system is on the
burglar alarm condition, the system must be changed to
the second burglar alarm condition from normal condition.
9T-10 REMOTE KEYLESS ENTRY AND ANTI-THEFT SYSTEM
5. Characteristic Signal : Right Picture
6. Time Interval
T1 : 2 ± 0.2sec.
T2 : three series of 30sec. “ON”, 10sec. “OFF”
T3 : 10min. ± 1min.
T4 : 0.25 ± 0.05sec.
T5 : 0.25 ± 0.05sec.
l
Cancellation of The Burglar Alarm
1. It is only possible to release the burglar alarm when unlocking
the driver’s door key cylinder switch, unlocking by REKES
transmitter or turning on the IGN 1,2.
2. Cancellation by an ignition key
3. Characteristic Signal : Right Picture
4. Time Interval
T1 : 1 ± 0.25sec.
5. Cancellation by REKES transmitter
6. Characteristic Signal : Light Picture
7. Time Interval
T1 : 1 ± 0.2sec.
SECTION 9U
CONTROL UNITS AND SYSTEM
Caution: Disconnect the negative battery cable before removing or installing any electrical unit or when a
tool or equipment could easily come in contact with exposed electrical terminals. Disconnecting this cable
will help prevent personal injury and damage to the vehicle. The ignition must also be in LOCK unless otherwise
noted.
TABLE OF CONTENTS
Specifications . . . . . . . . . . . . . . . . . . . . . . . . 9U-1
STICS Specifications . . . . . . . . . . . . . . . . . . . 9U-1
Schematic and Routing Diagrams . . . . . . . . 9U-2
STICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9U-2
Function Description . . . . . . . . . . . . . . . . . . 9U-3
SPECIFICATIONS
STICS SPECIFICATIONS
Description
DC 12V
Dc 9V - 16V
Less than 1mA(key is removed and all doors locked)
-30
°
C - +80
°
C
Between terminal No.5 and 3,4,8,12,18,25
Between terminal No. 5 and 2,6,7,16,17
Between terminal No.5 and 11, 27
Application
Voltage Rating
Voltage Rating
Current Consumption
Operating Temperature
Voltage Drop
(at DC 12V)
Max. 1.2V
Max. 1.8V
Max. 2.0V
STICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9U-3
Maintenance and Repair . . . . . . . . . . . . . . 9U-10
On-Vehicle Service . . . . . . . . . . . . . . . . . . . . . 9U-10
STICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9U-10