SECTION 1G1
M162 ENGINE INTAKE & EXHAUST
Specifications . . . . . . . . . . . . . . . . . . . . . . . 1G1-1
Fastener Tightening Specifications . . . . . . . . 1G1-1
Maintenance and Repair . . . . . . . . . . . . . . 1G1-2
On-Vehicle Service . . . . . . . . . . . . . . . . . . . . . 1G1-2
Air Cleaner . . . . . . . . . . . . . . . . . . . . . . . . . . 1G1-2
TABLE OF CONTENTS
Intake Air Duct . . . . . . . . . . . . . . . . . . . . . . . 1G1-4
Intake Manifold . . . . . . . . . . . . . . . . . . . . . . . 1G1-5
Resonance Flap . . . . . . . . . . . . . . . . . . . . . . 1G1-7
Exhaust Manifold . . . . . . . . . . . . . . . . . . . . . 1G1-9
SPECIFICATIONS
FASTENER TIGHTENING SPECIFICATIONS
N
l
m
9 - 11
22.5 - 27.5
22.5 - 27.5
9.5 - 12.5
15 - 28
28 - 47
Application
Air Cleaner Housing Cover Nut
Intake Manifold Bolt (M8 x 20)
Intake Manifold Bolt (M8)
Exhaust Mainfold Stud Bolt
Exhaust Pipe Nut (Engine)
Exhaust Pipe Bolt
1G1-2 M162 ENGINE INTAKE & EXHAUST
MAINTENANCE AND REPAIR
ON-VEHICLE SERVICE
AIR CLEANER
1 Air - Cleaner Assembly
2 Air - Cleaner Shield Upper Cover
3 Blot
4 Blot
5 Air Intake Shield
M162 ENGINE INTAKE & EXHAUST 1G1-3
Removal & Installation Procedure
1. Release the clamp securing HFM sensor and air cleaner.
2. Disengage the air cleaner assembly and HFM sensor
assembly.
3. Unserew the mounting bolt(6) from the bracket.
Installation Notice
Tightening Torque
22.5 - 27.5 Nm
4. Release the clamp from air cleaner assembly housing and
remove the cover.
5. Remove the air cleaner assembly.
6. Remove the air cleaner housing from insulator.
Notice
Make sure the air cleaner to be seated in insulator.
7. Disengage the air duct hose and air cleaner housing and
remove the housing.
8. Remove the air duct hose.
9. Unscrew the two bolts(7) from air inlet duct.
Installation Notice
10. Remove the air inlet duct.
11. Installation should follow the removal procedure in the
reverse order.
Tightening Torque
8 - 9 Nm
1G1-4 M162 ENGINE INTAKE & EXHAUST
INTAKE AIR DUCT
1 Clamp
2 Sleeve
3 Nut
4 Clamp
5 Intake Air Duct
3. Remove the clamp (4).
4. Remove the intake air duct (5) carefully.
Installation Notice
Exactly seat the pin of intake air duct onto the crankcase
ventilation rubber mount.
5. Installation should follow the removal procedure in the
reverse order.
Removal & Installation Procedure
1. Remove the clamp (1) and disconnect the HFM sensor.
2. Remove the nut (3) (arrow).
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.