Hyundai Tiburon (2003 year). Manual — part 152
TIBURON(GK) > 2003 > G 2.7 V6 DOHC > Heating,Ventilation, Air Conditioning > Controller > Manual Controller >
Schematic Diagrams, TIBURON(GK) > 2003 > G 2.7 V6 DOHC > Heating,Ventilation, Air Conditioning > Controller
> Manual Controller > Schematic Diagrams
CONNECTOR CONFIGURATIONS
I/NO PIN
CIRCUIT
REMARK
I/NO PIN
CIRCUIT
REMARK
A
1
RHEOSTAT
ILL (-)
B
1
INCAR SENSOR IN
2
TAIL LAMP
ILL (+)
2
A/C SELECT
HI OUTPUT
3
BATTERY
3
AMB SENSOR (+)
4
POWER TR(B)
4
EVA. SENSOR (+)
5
POWER TR(C)
5
-
6
-
6
-
7
HUMDITY
7
-
8
-
8
SENSOR REF (+5V)
9
TEMP ACT'R (CCW)
COOL
9
INCAR SENSOR OUT
10
INTAKE ACT'R (CCW)
FRESH
10
TEMP F/B SIGNAL
11
HTD
11
MODE F/B SIGNAL
12
IGN 2
12
-
13
GND
13
-
14
MODE ACT'R (CW)
VENT
14
-
15
MODE ACT'R (CCW)
OFF
15
-
16
-
16
SENSOR GND
17
A/CON OUTPUT
HI OUTPUT
18
HI SPEED RELAY
LOW OUTPUT
19
PHOTO SENSOR (+)
20
PHOTO SENSOR (GND)
21
REAR DEFOG
LOW OUTPUT
22
TEMP ACT'R (CW)
WARM
23
INTAKE ACT'R (CW)
REC
24
AQS SIGNAL
25
IGN 2
26
GND
WIRING DIAGRAM
TIBURON(GK) > 2003 > G 2.7 V6 DOHC > Heating,Ventilation, Air Conditioning > Controller > Manual Controller >
Description and Operation, TIBURON(GK) > 2003 > G 2.7 V6 DOHC > Heating,Ventilation, Air Conditioning >
Controller > Manual Controller > Description and Operation
DESCRIPTION
BUTTON CONTROL AND OPERATION LOGIC
1. All buttons should be back-up.
2. Push the button, then the operation sound is made for 0.1 sec. When a S/W is selected, and operation sound is made
as well).
NO
BUTTON
BUTTON
FUNCTION
DISPLAY
SYSTEM OPERATION
1
TEMP
TEMP
UP/DOWN
Set
temperature:
Display
1. Control the discharge air temperature by adjusting the
mixture ratio of cold & hot air with the TEMP DOOR.
2. Whenever press the SWITCH, temperature is changed
0.5°C up/down each time. (Each time the operation
sound is made for 0.1 sec.)
3. Set 17°C (62°F) as MAX COOL, 32°C (90°F) as MAX
HOT.
4. When the switch is turned ON from OFF, the set
temperature is displayed as the same before OFF.
5. When changing the set temperature from 17.5°C to
17°C or from 31.5°C to 32°C, the operation sound is
made.
6. At 17°C, if the temperature is set below than 17° C or
at 32°C , if it is above than 32°C , the operation sound
is made 5times at an interval of 0.15 sec.
7. When pushing the TEMP button several times, the set
temperature is shifted to another step at an interval of
0.7sec., When engaging the button continuously (keep
pushing), only the first shift takes 0.7 sec. but the next
shifts take 0.3 sec.
OFF SW AND SYSTEM OPERATION
- OFF: SYSTEM OFF
- TEMP: SET TEMPERATURE UP/DOWN
2
AUTO
AUTO
CONTROL
"AUTO": Display 1. Automatically control the following items
corresponding to theset temperature.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.