Hyundai Tiburon (2003 year). Manual — part 132
FAIL SAFE FUNCTION
00
Normal
-
11
Open INCAR Sensor circuit
• Incar sensor
• Harness or connector between incar sensor and A/C
control assembly
• A/C control assembly
12
Shorted INCAR Sensor circuit
13
Open Ambient sensor circuit
• Ambient sensor
• Harness or connector between ambient sensor and A/C
control assembly
• A/C control assembly
14
Shorted Ambient sensor circuit
15
Open water temp. sensor
• Water temp. sensor
• Harness or connector between water temp. sensor and
A/C control assembly
• A/C control assembly
16
Shorted water temp. sensor
17
Open thermistor
• Pin thermistor
• Harness or connector between evap. sensor and A/C
control assembly
• A/C control assembly
18
Shorted thermistor
19
Open or shorted temp. door potentiometer
• Harness or connector between temp. door potentiometer
and A/C control assembly
20
Defective temp. door potentiometer
• Temp. door potentiometer
21
Open or shorted mode door potentiometer
• Harness or connector between mode door potentiometer
and A/C control assembly
22
Defective mode door potentiometer
• Mode door potentiometer
No.
Item
Failure
FAIL SAFE Function
1
IN-CAR temperature sensor
Open/Short
25°C alternate value control
2
Ambient temperature sensor
Open/Short
20°C alternate valu e control
3
Thermistor sensor
Open/Short
-2°C alternate value contr ol
4
Water temperature sensor
Open/Short
-20°C alternate valu e control
5
Temperature door potentiometer
Open/Short setup
temperature
For 17°C to 24.5°C, set to maximum cooling
position.
For 25°C to 32°C, set to maximum heating
position.
6
Mode door potentimeter
Open/Short setup
mode
Vent mode, at vent mode
Def mode, at except vent mode
Use the table below to help you find the cause of the problem. The numbers indicate the priority of the likely
cause of the problem. Check each part in order. If necessary, replace these parts
STANDARD
TIBURON(GK) > 2003 > G 2.7 V6 DOHC > Heating,Ventilation, Air Conditioning > General Information >
Troubleshooting, TIBURON(GK) > 2003 > G 2.7 V6 DOHC > Heating,Ventilation, Air Conditioning >
General Information > Troubleshooting
TROUBLESHOOTING
PROBLEM SYMPTOMS TABLE
Symptom
Suspect Area
Remedy
No blower operation
1. HTR Fuse
2. Blower relay
3. Blower motor
4. Blower resistor
5. Blower speed control switch
6. Wire harness
Replace
Replace
Replace
Replace
Replace
Replace
No air temperature control
1. Engine coolant capacity
2. Heater control assembly
Add coolant
Replace
No compressor operation
1. Refrigerant capacity
2. A/C Fuse
3. Magnetic clutch
4. Compressor
5. Triple pressure switch
6. A/C switch
7. Thermistor
8. Wire harness
Add refrigerant
Replace
Replace
Replace
Replace
Replace
Replace
Replace
No cool comes out
1. Refrigerant capacity
2. Refrigerant pressure
3. Drive belt
4. Magnetic clutch
5. Compressor
6. Triple pressure switch
7. Thermistor
8. A/C switch
9. Heater control assembly
10. Wire harness
Add refrigerant
Apply a vacuum and add
refrigerant
Adjust
Replace
Replace
Replace
Replace
Replace
Replace
Replace
Insufficient cooling
1. Refrigerant capacity
2. Drive belt
3. Magnetic clutch
4. Compressor
5. Condenser
6. Expansion valve
7. Evaporator
8. Refrigerant lines
9. Triple pressure switch
10. Heater control assembly
Add refrigerant
Adjust
Replace
Replace
Replace
Replace
Replace
Replace
Replace
Replace
No engine idle-up when A/C switch
ON
1. Engine (and ECT) ECU
2. Wire harness
-
Replace
No air inlet control
Heater control assembly, cable, door
Replace
No mode control
Heater control assembly, cable, door
Replace
No condenser fan operation
1. ECU-IG Fuse
2. Fan motor
3. Engine (and ECT) ECU
4. Wire harness
Replace
Replace
-
Replace
This is a method in which the trouble is located by using a manifold gauge set. Read the manifold gauge pressure when the
these conditions are established.
TIBURON(GK) > 2003 > G 2.7 V6 DOHC > Heating,Ventilation, Air Conditioning > General Information > Repair
procedures, TIBURON(GK) > 2003 > G 2.7 V6 DOHC > Heating,Ventilation, Air Conditioning > General Information >
Repair procedures
ON-VEHICLE INSPECTION
TEST CONDITIONS
• Temperature at the air inlet with the switch set at RECIRC is 30~35°C (86~95°F)
• Engine running at 1,500rpm
• Blower speed control knob on "4" position
• Temperature control knob on "COOL" position
It should be noted that the gauge indications may vary slightly due to ambient temperature conditions.
1. Normally functioning refrigeration system.
Gauge reading :
Low pressure side :
0.15~0.25 MPa (21.8~36.3 psi, 1.5~2.5 kgf/cm²)
High pressure side :
1.37~1.57 MPa (199~228 psi, 14~16 kgf/cm²)
2. Moisture present in refrigeration system.
Symptom seen in
refrigeration system
Probable cause
Diagnosis
Remedy
During operation, pressure
on low pressure side
sometimes become a
vacuum and sometime
normal
Moisture entered in
refrigeration system freezes
at expansion valve orifice
and temporarily stops cycle,
but normal state is restored
after a time when the ice
melts
• Drier in oversaturected
state
• Moisture in refrigeration
system freezes at
expansion valve orifice
and block circulation of
refrigerant
- Raplace drier
- Remove moisture in
cycle through repeatedly
evacuating air
- Charge proper amount of
new refrigerant
3. Insufficient cooling