Chrysler Sebring, Stratus sedan, Sebring Convertible. Manual — part 76
TEST
ACTION
APPLICABILITY
7
Turn the ignition off
Ensure the Body Control Module C2 harness connector is connected.
Reconnect the C200 in-line connector (HVAC) located in the center of the instrument
panel above the accelerator pedal.
Disconnect the Mode Door Actuator harness connector.
Turn the ignition on.
With the DRBIII
t, record and erase Body Computer DTC’s.
Cycle the ignition switch.
Start the engine.
With the DRBIII
t in Miscellaneous, actuate Calibrate HVAC Door Motors.
With the DRBIII
t, read the Body Computer DTCs.
Does the DRBIII
t display: XXXX Door Output Short To Batt?
All
Yes
→ Go To 8
No
→ Replace the Mode Door Actuator in accordance with the Service
Information.
Calibration must be performed after repair/replacement is com-
pleted.
Perform BODY VERIFICATION TEST - VER 1.
8
Turn the ignition off.
Disconnect the C200 in-line connector (HVAC) located in the center of the instrument
panel above the accelerator pedal.
Disconnect the Blend Door Actuator harness connector.
Measure the resistance between the Common Door Driver circuit and the Blend Door
Driver circuit.
Is the resistance below 10K ohms?
All
Yes
→ Repair the Blend Door Driver circuit for a short to the Common
Door Driver circuit.
Calibration must be performed after repair/replacement is com-
pleted.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Go To 9
9
Turn the ignition off
Ensure the Body Control Module C2 harness connector is connected.
Reconnect the C200 in-line connector (HVAC) located in the center of the instrument
panel above the accelerator pedal.
Disconnect the Blend Door Actuator harness connector.
Turn the ignition on.
With the DRBIII
t, record and erase Body Computer DTC’s.
Cycle the ignition switch.
Start the engine.
With the DRBIII
t in Miscellaneous, actuate Calibrate HVAC Door Motors.
With the DRBIII
t, read the Body Computer DTCs.
Does the DRBIII
t display: XXXX Door Output Short To Batt?
All
Yes
→ Go To 10
No
→ Replace the Blend Door Actuator in accordance with the Service
Information.
Calibration must be performed after repair/replacement is com-
pleted.
Perform BODY VERIFICATION TEST - VER 1.
289
HEATING & A/C
BLEND DOOR OUTPUT SHORT TO BATTERY - ATC & MTC —
Continued
TEST
ACTION
APPLICABILITY
10
Disconnect the C200 in-line connector (HVAC) located in the center of the instrument
panel above the accelerator pedal.
Disconnect the Recirculation Door Actuator harness connector.
Measure the resistance between the Recirculation Door Driver circuit and the
Common Door Driver circuit.
Is the resistance below 10K ohms?
All
Yes
→ Repair the Recirculation Door Driver circuit for a short to the
Common Door Driver circuit.
Calibration must be performed after repair/replacement is com-
pleted.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Replace the Recirculation Door Actuator in accordance with the
Service Information.
Calibration must be performed after repair/replacement is com-
pleted.
Perform BODY VERIFICATION TEST - VER 1.
11
Turn the ignition off.
NOTE: Visually inspect the related wiring harness and circuits. Look for
any chafed, pierced, pinched, or partially broken wires.
NOTE: Visually inspect the related wiring harness connectors. Look for
broken, bent, pushed out, or corroded terminals.
NOTE: Refer to any Technical Service Bulletins (TSB) that may apply.
Were any problems found?
All
Yes
→ Repair as necessary.
Calibration must be performed after repair/replacement is com-
pleted.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Test Complete.
290
HEATING & A/C
BLEND DOOR OUTPUT SHORT TO BATTERY - ATC & MTC —
Continued
Symptom List:
BLEND DOOR OUTPUT SHORT TO GROUND - ATC & MTC
COMMON OUTPUT SHORT TO GROUND - ATC & MTC
MODE DOOR OUTPUT SHORT TO GROUND - ATC & MTC
RECIRC DOOR OUTPUT SHORT TO GROUND - ATC & MTC
Test Note:
All symptoms listed above are diagnosed using the same tests.
The title for the tests will be BLEND DOOR OUTPUT SHORT
TO GROUND - ATC & MTC.
When Monitored and Set Condition:
BLEND DOOR OUTPUT SHORT TO GROUND - ATC & MTC
When Monitored:
Whenever the BCM attempts to drive one of the HVAC actuators.
Set Condition:
This DTC will set if the BCM detects one or more of the following outputs
shorted to ground: mode door driver, blend door driver, recirculation door driver or the
common door driver.
COMMON OUTPUT SHORT TO GROUND - ATC & MTC
When Monitored:
Whenever the BCM attempts to drive one of the HVAC actuators.
Set Condition:
This DTC will set if the BCM detects one or more of the following outputs
shorted to ground: mode door driver, blend door driver, recirculation door driver or the
common door driver.
MODE DOOR OUTPUT SHORT TO GROUND - ATC & MTC
When Monitored:
Whenever the BCM attempts to drive one of the HVAC actuators.
Set Condition:
This DTC will set if the BCM detects one or more of the following outputs
shorted to ground: mode door driver, blend door driver, recirculation door driver or the
common door driver.
RECIRC DOOR OUTPUT SHORT TO GROUND - ATC & MTC
When Monitored:
Whenever the BCM attempts to drive one of the HVAC actuators.
Set Condition:
This DTC will set if the BCM detects one or more of the following outputs
shorted to ground: mode door driver, blend door driver, recirculation door driver or the
common door driver.
POSSIBLE CAUSES
DOOR DRIVER CIRCUIT(S) SHORTED TO GROUND
DOOR DRIVER CIRCUIT(S) SHORTED TO SENSOR GROUND
DOOR DRIVER CIRCUIT SHORTED TO OTHER DOOR DRIVER CIRCUIT(S)
COMMON DOOR DRIVER CKT SHORTED TO OTHER DOOR DRIVER CKT(S) - IP HARNESS
SIDE
291
HEATING & A/C
POSSIBLE CAUSES
BODY CONTROL MODULE
MODE DOOR DRIVER CIRCUIT SHORTED TO COMMON DOOR DRIVER CIRCUIT
MODE DOOR ACTUATOR
BLEND DOOR DRIVER CIRCUIT SHORTED TO COMMON DOOR DRIVER CIRCUIT
BLEND DOOR ACTUATOR
RECIRCULATION DOOR DRIVER CIRCUIT SHORTED TO COMMON DOOR DRIVER CIRCUIT
RECIRCULATION DOOR ACTUATOR
WIRING CAUSING INTERMITTENT CONDITION
TEST
ACTION
APPLICABILITY
1
Turn the ignition on.
With the DRBIII
t, record and erase Body Computer DTC’s.
Cycle the ignition switch.
Start the engine.
With the DRBIII
t in Miscellaneous, actuate Calibrate HVAC Door Motors.
With the DRBIII
t, read the Body Computer DTCs.
Does the DRBIII
t display: XXXX Door Output Short To Ground?
All
Yes
→ Go To 2
No
→ Go To 12
2
Turn the ignition off.
Disconnect the Body Control Module C2 harness connector.
Measure the resistance between ground and each of the Door Driver circuits (Blend,
Mode, Recirc, & Common).
Is the resistance below 10K ohms on any of the circuits?
All
Yes
→ Repair all Door Driver circuits with a resistance below 10K ohms
for a short to ground.
Calibration must be performed after repair/replacement is com-
pleted.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Go To 3
3
Turn the ignition off.
Disconnect the Body Control Module C2 harness connector.
Measure the resistance between Sensor Ground and each of the Door Driver circuits
(Blend, Mode, Recirc, & Common).
Is the resistance below 10K ohms on any of the circuits?
All
Yes
→ Repair all Door Driver circuits with a resistance below 10K ohms
for a short to Sensor Ground.
Calibration must be performed after repair/replacement is com-
pleted.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Go To 4
292
HEATING & A/C
BLEND DOOR OUTPUT SHORT TO GROUND - ATC & MTC —
Continued