Chrysler Sebring, Stratus sedan, Sebring Convertible. Manual — part 225
Symptom List:
P1603-PCM INTERNAL DUAL-PORT RAM COMMUNICATION
P1604-PCM INTERNAL DUAL-PORT RAM READ/WRITE INTEG-
RITY FAILURE
P1607-PCM INTERNAL SHUTDOWN TIMER RATIONALITY
Test Note:
All symptoms listed above are diagnosed using the same tests.
The title for the tests will be P1603-PCM INTERNAL DUAL-
PORT RAM COMMUNICATION.
When Monitored and Set Condition:
P1607-PCM INTERNAL SHUTDOWN TIMER RATIONALITY
When Monitored:
During cold start.
Set Condition:
Compares shut down time to coolant temperature.
POSSIBLE CAUSES
FUSED IGNITION SWITCH OUTPUT (OFF-RUN-START)
PCM INTERNAL FAULURE
TEST
ACTION
APPLICABILITY
1
Turn the ignition off.
Disconnect the PCM harness connector.
CAUTION: DO NOT PROBE THE PCM HARNESS CONNECTORS. PROBING
THE PCM HARNESS CONNECTORS WILL DAMAGE THE PCM TERMI-
NALS RESULTING IN POOR TERMINAL TO PIN CONNECTION. INSTALL
MILLER SPECIAL TOOL #8815 TO PERFORM DIAGNOSIS.
Turn the ignition to run.
Using a 12-volt test light connected to ground, probe the Fused Ignition Switch
Output (Off-Run-Start) cavity C1-12 circuit at the appropriate terminal of the special
tool #8815.
NOTE: If the test light illuminates, wiggle the wiring harness to ensure that
the problem is not an intermittent wiring problem.
Does the test light illuminate brightly?
All
Yes
→ Replace the Powertrain Control Module in accordance with the
Service Information.
Perform POWERTRAIN VERIFICATION TEST VER - 1.
No
→ Check all related fuses. Repair the Fused Ignition Switch Output
circuit.
Perform POWERTRAIN VERIFICATION TEST VER - 1.
277
DRIVEABILITY - NGC
Symptom List:
P1696-EEPROM MEMORY WRITE DENIED/INVALID
P1697-EMR (SRI) MILEAGE NOT STORED
Test Note:
All symptoms listed above are diagnosed using the same tests.
The title for the tests will be P1696-EEPROM MEMORY
WRITE DENIED/INVALID.
When Monitored and Set Condition:
P1696-EEPROM MEMORY WRITE DENIED/INVALID
When Monitored:
Ignition key on continuous.
Set Condition:
An attempt to program/write to the internal EEPROM failed. Also checks
at powerdown.
P1697-EMR (SRI) MILEAGE NOT STORED
When Monitored:
Ignition key on continuous.
Set Condition:
An attempt to program/write to the internal EEPROM failed. Also checks
at powerdown.
POSSIBLE CAUSES
DRB DISPLAYS WRITE FAILURE
DRB DISPLAYS WRITE REFUSED 2ND TIME
DRB DISPLAYS SRI MILEAGE INVALID
COMPARE SRI MILEAGE WITH ODOMETER
TEST
ACTION
APPLICABILITY
1
With the DRBIII
t, perform the SRI Memory Test.
Does the DRBIII
t display Write Failure?
All
Yes
→ Replace and program the Powertrain Control Module in accor-
dance with the Service Information.
Perform POWERTRAIN VERIFICATION TEST VER - 1.
No
→ Go To 2
2
With the DRBIII
t, perform the SRI Memory Test.
Does the DRBIII
t display Write Refused?
All
Yes
→ Go To 3
No
→ Go To 4
278
DRIVEABILITY - NGC
TEST
ACTION
APPLICABILITY
3
With the DRBIII
t, perform the SRI Memory Test a second time.
NOTE: Retest the SRI Memory two more times.
Does the DRBIII
t display Write Refused again?
All
Yes
→ Replace and program the Powertrain Control Module in accor-
dance with the Service Information.
Perform POWERTRAIN VERIFICATION TEST VER - 1.
No
→ Test Complete.
4
With the DRBIII
t, perform the SRI Memory Test.
Does the DRBIII
t display SRI Mileage Invalid?
All
Yes
→ Update the mileage and retest the SRI Memory.
Perform POWERTRAIN VERIFICATION TEST VER - 1.
No
→ Go To 5
5
Compare the SRI Mileage stored with the Instrument Panel Odometer.
Is the mileage within the specified range displayed on the DRBIII
t?
All
Yes
→ Test Complete.
No
→ Update the mileage and retest the SRI Memory.
Perform POWERTRAIN VERIFICATION TEST VER - 1.
279
DRIVEABILITY - NGC
P1696-EEPROM MEMORY WRITE DENIED/INVALID —
Continued
Symptom:
P2074-MANIFOLD PRESSURE/THROTTLE POSITION CORRELA-
TION - HIGH FLOW/VACUUM LEAK
When Monitored and Set Condition:
P2074-MANIFOLD PRESSURE/THROTTLE POSITION CORRELATION - HIGH
FLOW/VACUUM LEAK
When Monitored:
Engine Running, during all drive modes.
Set Condition:
If vacuum drops below 1.5 Hg with engine RPM greater than 2000 RPM
at closed throttle.
POSSIBLE CAUSES
GOOD TRIP EQUAL TO ZERO
VACUUM LEAK
HIGH RESISTANCE IN MAP (K6) 5 VOLT SUPPLY CIRCUIT
RESISTANCE TO GROUND IN MAP (K6) 5 VOLT SUPPLY CIRCUIT
MAP SENSOR
HIGH RESISTANCE IN (K1) MAP SIGNAL CIRCUIT
RESISTANCE TO GROUND IN (K1) MAP SIGNAL CIRCUIT
HIGH RESISTANCE IN (K4) MAP GROUND CIRCUIT
PCM
TP SENSOR OPERATION
HIGH RESISTANCE IN TP SENSOR (K6) 5 VOLT SUPPLY CIRCUIT
RESISTANCE TO GROUND IN TP SENSOR (K6) 5 VOLT SUPPLY CIRCUIT
TP SENSOR
HIGH RESISTANCE IN (K22) TP SIGNAL CIRCUIT
RESISTANCE TO GROUND IN (K22) TP SENSOR SIGNAL CIRCUIT
HIGH RESISTANCE IN TP (K4) SENSOR GROUND CIRCUIT
PCM
280
DRIVEABILITY - NGC