Symptom:
INCOMPLETE POWER CLOSE - VOLTAGE BELOW MINIMUM
LEVEL
When Monitored and Set Condition:
INCOMPLETE POWER CLOSE - VOLTAGE BELOW MINIMUM LEVEL
When Monitored:
Whenever the power liftgate is performing a power close operation.
Set Condition:
The PLG Module detects that the voltage is below 9.5 volts during the
power close operation.
POSSIBLE CAUSES
DTC PRESENT
MODULE VOLTAGE LOW
BINDING LIFTGATE
DRB OPERATING VOLTAGE LOW
PLG MODULE - HIGH RESISTANCE
POWER LIFTGATE DRIVE MOTOR
TEST
ACTION
APPLICABILITY
1
With the DRBIII
t, record and erase DTC’s.
Turn the ignition off, wait 10 seconds, then turn the ignition on.
Operate the power liftgate several times if possible.
With the DRBIII
t, read DTCs.
Does the DRBIII
t display INCOMPLETE POWER CLOSE - VOLTAGE BELOW
MINIMUM LEVEL?
All
Yes
→ Go To 2
No
→ Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors for an intermittent condition. Operate the
door several times and check for any binding conditions.
Perform BODY VERIFICATION TEST - VER 1.
2
Examine the liftgate for proper fit and alignment, or anything that would cause an
obstruction to proper operation.
Check the prop rods to ensure liftgate will fall closed from the approximately 3/4
closed position.
Does it take more effort to operate the liftgate than it should?
All
Yes
→ Refer to Service information for the related symptom(s).
Perform BODY VERIFICATION TEST - VER 1.
No
→ Go To 3
849
POWER DOORS - LIFTGATE
TEST
ACTION
APPLICABILITY
3
NOTE: Test the battery to ensure it is fully charged and in good condition
before proceeding.
Turn the ignition off.
Turn all lights and accessories off.
With the DRBIII
t in 9Power Liftgate9 9Monitor Display9 9PCI Bus Info9 read the
9Battery Voltage9 and compare it to the 9PLG Bat Volts Input9.
NOTE: If the difference is greater than 0.5 volts, backprobe the Fused B(+)
at the module to verify.
Does the voltage vary more than 0.5 volts?
All
Yes
→ Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors. Locate and repair the reason for the
voltage drop.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Go To 4
4
Turn the ignition off.
Turn all lights and accessories off.
With the DRBIII
t in 9Power Liftgate99 9Monitor Display9 9PCI Bus Info9 read the
9Battery Voltage9 and compare it to the 9PLG Bat Volts Input9.
Operate the power liftgate and observe the voltage difference.
NOTE: If the difference is greater than 1.6 volts, backprobe the Fused B(+)
at the module to verify.
Does the voltage vary more than 1.6 volts when the liftgate is operating?
All
Yes
→ Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors. Locate and repair the reason for the
voltage drop.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Go To 5
5
Turn the ignition off.
Turn all lights and accessories off.
Open the Liftgate.
Remove the left rear trim panel to gain access to the Power Liftgate Module.
Remove the PLG module but leave it connected.
Backprobe voltmeter leads between the Fused B(+) and the Liftgate Close Driver
circuits in the PLG C1 connector.
Operate the power liftgate in the CLOSED position and observe the voltage
difference.
Does the voltage vary more than 1.0 volts when the liftgate is operating??
All
Yes
→ Replace the Power Liftgate Module.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Go To 6
6
If there are no possible causes remaining, view repair.
All
Repair
Check the wiring and connections from the module to the motor
for high resistance. If the wiring is okay, replace the Power
Liftgate Drive Motor.
Perform BODY VERIFICATION TEST - VER 1.
850
POWER DOORS - LIFTGATE
INCOMPLETE POWER CLOSE - VOLTAGE BELOW MINIMUM LEVEL —
Continued
Symptom:
INCOMPLETE POWER CLOSE -TIME OUT
When Monitored and Set Condition:
INCOMPLETE POWER CLOSE -TIME OUT
When Monitored:
Anytime the Power Liftgate is in a power close operation.
Set Condition:
If the unit takes longer than 20 seconds to complete the close cycle, this
code will set.
POSSIBLE CAUSES
DTC PRESENT
BINDING LIFTGATE
LIFTGATE DRIVER CIRCUIT PARTIAL SHORT TO GROUND
MODULE VOLTAGE LOW
DRB OPERATING VOLTAGE LOW
PLG MODULE
TEST
ACTION
APPLICABILITY
1
NOTE: When this code is set, the module will abort the power close cycle
and begin
(Clutch Pulsing(. This is where the module will cycle the Liftgate
Clutch Driver until the gate stops moving (based on Optical Sensor inputs).
With the DRBIII
t, record and erase DTC’s.
Turn the ignition off, wait 10 seconds, then turn the ignition on.
Operate the power liftgate several times if possible.
With the DRBIII
t, read DTCs.
Does the DRBIII
t display INCOMPLETE POWER CLOSE - TIME OUT?
All
Yes
→ Go To 2
No
→ Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors for an intermittent condition. Operate the
liftgate several times and check for any binding conditions.
Perform BODY VERIFICATION TEST - VER 1.
2
Examine the liftgate for proper fit and alignment, or anything that would cause an
obstruction to proper operation.
Check the prop rods to ensure liftgate will self rise from approximately 1/4 open
position.
Manually operate the liftgate several times.
If necessary, manually operate the liftgate of a known good vehicle and notice the
effort needed to open it.
Does it take more effort to operate the liftgate of the disabled vehicle than it should?
All
Yes
→ Refer to Service information for the related symptom(s).
Perform BODY VERIFICATION TEST - VER 1.
No
→ Go To 3
851
POWER DOORS - LIFTGATE
TEST
ACTION
APPLICABILITY
3
Disconnect the Liftgate Drive Unit C1 connector.
Measure the resistance between ground and the Liftgate Close Driver circuit.
Is the resistance below 1000.0 ohms?
All
Yes
→ Locate and repair the liftgate driver circuit for a partial short to
ground. It could be in either the Open or the Close circuit. If the
drive circuits are okay, replace the drive motor.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Go To 4
4
NOTE: Test the battery to ensure it is fully charged and in good condition
before proceeding.
Turn the ignition off.
Turn all lights and accessories off.
NOTE: Ensure all the connectors are connected before proceeding with this
step.
With the DRBIII
t in 9Power Liftgate9 9Monitor Display9 9PCI Bus Info9 read the
9Battery Voltage9 and compare it to the 9PLG Bat Volts Input9.
NOTE: If the difference is greater than 0.5 volts, backprobe the Fused B(+)
at the module to verify.
Does the voltage vary more than 0.5 volts?
All
Yes
→ Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors. Locate and repair the reason for the
voltage drop.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Go To 5
5
Turn the ignition off.
Turn all lights and accessories off.
With the DRBIII
t in 9Power Liftgate99 9Monitor Display9 9PCI Bus Info9 read the
BATTERY VOLTAGE and compare it to the MODULE VOLTAGE.
Operate the power liftgate and observe the voltage difference.
NOTE: If the difference is greater than 1.6 volts, backprobe the Fused B(+)
at the module to verify.
Does the voltage vary more than 1.6 volts when the liftgate is operating??
All
Yes
→ Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors. Locate and repair the reason for the
voltage drop.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Replace the Power Liftgate Module.
Perform BODY VERIFICATION TEST - VER 1.
852
POWER DOORS - LIFTGATE
INCOMPLETE POWER CLOSE -TIME OUT —
Continued