Chrysler Crossfire. Manual — part 997

INSTALLATION

1. Install the recirculation switchover valve.

2. Connect the recirculation switchover valve harness

connector to the recirculation switchover valve.

3. Connect the vacuum lines (1) to the recirculation

switchover valve.

4. Install the glove compartment. (Refer to 23 -

BODY/INSTRUMENT

PANEL/GLOVE

BOX

-

INSTALLATION).

ZH

CONTROLS

24 - 91

2. Disconnect the blower motor electrical connector

(1) from the relief in the blower motor door.

3. Slide the blower motor door catch mounts (1) to

the sides.

4. Swing the blower motor door down.

5. Remove the screws (1) attaching the blower motor

to the heater housing.

6. Remove the blower motor and squirrel cage as an

assembly.

ZH

DISTRIBUTION

24 - 93

REMOVAL - RHD

1. Disconnect the negative battery cable.

2. Remove the left lower instrument panel cover (2)

from the instrument panel (1).

3. Disconnect the blower motor harness connector (1)

from the relief in the blower motor door.

24 - 94

DISTRIBUTION

ZH