SsangYong Korando III (2010 year). Manual — part 251
15-8
The front sub frame consists of 4 body bush mountings(A) and 2 engine bush mountings(B) which
reduce the vibration from the powertrain and road, and also control the torque. And the two engine bush
mountings consist of an engine mounting which supports the engine powertrain and a transmission
mounting.
The engine side and transmission side mountings are rubber mountings with brackets and insulators
while the body mounting is a rubber bush mounting which is fitted to the frame.
Installation of front sub
frame (4WD)
The installation of the front sub frame is the same for both automatic
transmission and manual transmission. For 4WD, the PTU and the
propeller shaft are installed.
Installation of front sub
frame (2WD)
The installation of the front sub frame is the same for both automatic
transmission and manual transmission.
PTU assembly
15-9
4015-01
Installation of rear sub
frame (4WD)
The installation of the rear sub frame is the same for both automatic
transmission and manual transmission. For 4WD, the E-coupling, propeller
shaft and rear axle are installed.
Installation of rear sub
frame (2WD)
The installation of the rear sub frame is the same for both automatic
transmission and manual transmission.
The rear sub frame system consists of body bush mountings and direct mountings which reduce the
vibration transmitted from the powertrain and road to the vehicle body.
For 4WD, it consists of 4 body mountings (bush mountings) and 2 axle mountings (bush mountings) and
for 2WD, it consists of 4 body mountings (direct mountings).
01-3
6810-00
1. SPECIFICATION
Description
Specification
Heater
Core size (㎣)
200 x 165.5 x 25
Capacity (kcal/h)
4,800
Evaporator
Core size (㎣)
254.8 x 196.75 x 60
Capacity (kcal/h)
4,700
Blower
Supply power (W)
240 + 10% Max (at 12 V)
Fan speed (rpm)
2900±200 Max
(Rec.Mode: 420㎥/h)
PTC
Supply power
1 kW
Condenser
Core size (㎣)
588 x 455 x 16 (2,625)
Capacity (kcal/h)
12,000
Capacity of receiver drier
250 cc
compressor
Capacity
170 cc/rev
Diameter of pulley
Ø120
Max. continuous speed
8,000 rpm
voltage
DC 12 V
Power consumption
2.2 A
01-4
2. MAJOR CHANGES
1) Heater & Evaporator Module (Wiring Specification)
The driving circuit for the manual A/C ambient temperature sensor is added, giving the change to the
heater and evaporator module.
Ambient temperature sensor signal wiring
added to vehicle wiring connecting
connector (2 circuits)
: manual A/C
Blower max signal wiring added to
vehicle wiring connecting connector
(1 circuit)
: manual A/C & FATC
Manual A/C: Wiring pin added to controller assembly connector
FATC: Wiring pin added to existing connector of controller assembly