SsangYong Korando III (2010 year). Manual — part 473

05-24

When the ignition is switched off, the message "GOOD-BYE" is displayed for 2 seconds and disappears.

The other LCDs go off as soon as the ignition is switched off.

The dial and pointer dim down for 2 seconds and go off at the same time when the DOT LCD goes off.

7.

05-25

8010-01

Operations for power supply in STD

The operation input before the LCD backlight is illuminated, right after the ignition is turned OFF or ON,

is ignored.
The LCD backlight and other lamps are illuminated 0.4 ±0.1 second after the ignition ON is

detected.

The LCD display, LCD backlight, dial lamp and indicator lamp are turned on or off by the ignition

switch ON/OFF operation.

-

-

-

05-26

Brightness in SVC

(2) Illumination Level

Brightness in STD

Operating power

Illumination level

Main LCD, dial point

Day

Night

B+

(B-CAN Wake UP)

- OFF

OFF

IGN 1

Level 1

100%

20%

Level 2

100%

30%

Level 3

100%

40%

Level 4

100%

50%

Level 5

100%

60%

Level 6

100%

70%

작동전원

Illumination

level

DOT LCD

ODO, gauge LCD, dial pointer

Day

Night

Day

Night

B+(B-CAN

Wake UP)

Initial

time

-

Level 6

Level 6

OFF (however, level 6 for initial
operation with B+ & IGN1 ON)

After

initial

time

Maintain
previous

level

Maintain
previous

level

OFF (however, maintains
previous level for initial operation
with B+ & IGN1 ON)

IGN 1

Level 1

25%

5%

25%

5%

Level 2

40%

12%

40%

12%

Level 3

55%

19%

55%

19%

Level 4

70%

26%

70%

26%

Level 5

85%

33%

85%

33%

Level 6

100%

40%

100%

40%

Operating power

IGN 1

05-27

8010-01

(1) SVC

Symbols in SVC

5) System Analysis